Brooklyn · Block 3043 · Lot 19 · 11206

193 Graham Avenue

3 floors · 2 apartments · 4,650 sq ft · built 1920 · class M9 · owner of record: 193 Graham Llc

14open violations
$8,750ECB/OATH penalties owed
1HPD class C (immediately hazardous)
52dto Annual boiler inspection (1 boiler)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 52 days
Keep the report on file (not filed with DOB)
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2023-04-10 (Accepted). Agency page

Dec 31, 2026
in 52 days
1 of 1 without an accepted 2026 report yet
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 296 days
Required only if the owner doesn't live there
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 783 days
Next cycle year 2028

Open violations

ECB / OATH (8) · $8,750 owed
IssuedViolationHearingBalance
Jun 15, 2026Construction CLASS - 2
OBSERVED POOR/UNSAFE HOUSEKEEPING CONDITIONS. CONDITIONS WERE LEFT AROUND THE SITE OVER THE WEEKEND. DEBRIS AND MATERIAL PILED IN THE PATHWAYS OF THE BUILDING. GARBAGE BAGS LEFT AROUND SITE AND ON TOP OF THE AD
#39555493J
May 3, 2027
$1,250
Jun 15, 2026Unknown CLASS - 2
B.C 3307.4.7 OBSERVED A STORAGE ZONE AREA IN PLACE AT EXPO#4 OF THE SITE. A BOOM TRUCK, GARBAGE DEBRIS AND CONSTRUCTION MATERIAL STORED ON THE STREET AND NOT FULLY ENCLOSED WITH JERSEY BARRIERS. THE SECTION OF
#39555528K
May 3, 2027
PENDING
$2,500
Jun 15, 2026Unknown CLASS - 2
OBSERVED AT THE ROOF LEVEL OF THE BUILDING WAS NOT COMPLETED. PARAPET AROUND THE ROOF STILL NEEDS TO INSTALL THE METAL COPING AND 42" METAL RAILINGS AROUND THE ENTIRE ROOF AND BULKHEAD. ALSO THE BULK HEAD EXTER
#39555492H
May 3, 2027
$2,500
Nov 24, 2025Construction CLASS - 2
VERTICAL & HORIZONTAL ENLARGEMENT OF EXISTING 3 STORY RESIDENTIAL TO 6 STORY. OBSERVED: ACTIVE SITE CP PRESENT UPON INSPECTION REQUEST FOR SSP AND PERIODIC INSPECTION LETTER FOR SWS NONE WAS PROVIDDED CONTRARY
#39547306P
Apr 8, 2027
$1,250
Nov 24, 2025Construction CLASS - 2
VERTICAL & HORIZONTAL ENLARGEMENT OF EXISTING 3 STORY RESIDENTIAL TO 6 STORY. OBSERVED: ACTIVE SITE CP PRESENT UPON INSPECTION NOTED FENCE HAS BEEN ERECTED ON EXP 1,4 UPON REVIEW ON APPROVED DRAWINGS NOTED MISS
#39547307R
Apr 8, 2027
$1,250
Nov 7, 2009Construction CLASS - 1
FAILURE TO MAINTAIN BLDG WALL OR APPURTENANCE NOTE VERTICAL & HORIZONTAL CRACKS OBSERVED THROUGHOUT THE FRONT AND #4 FACADES CRACKS ALSO OBSERVED ON THE REAR EXTERIOR WALL FURTHER A VERTICAL CRACK AT THE PARAPE
#34818418J
Jul 19, 2010
IN VIOLATION
$0
Jun 3, 2009Construction CLASS - 1
FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES DEFECTS NOTED AT EXP 1 AND EXP 4 SEVERE CRACKS IN BLDG WALL AT EXP 4 SEVERE CRACK IN COLUMN WHERE EXP 4 MEETS EXP 1 CRACKS THRU STONE LINTELS BELOW 3RD FL
#34776073K
Jul 27, 2009
IN VIOLATION
$0
Sep 27, 2005Construction Hazardous
FAILURE TO MAINTAIN EXTERIOR BLDG WALLS. NOTE: AT REAR OF 1ST FLOOR BRICK EXTENSION IS CRACK VERTICALLY & HORIZONTALLY APPROX 2"WIDE AT VARIOUS LOCATIONS IN WHICH 1ST FLOOR EXTENSION PARAPET WALL IS LEANING
#34496462H
Nov 14, 2005
IN VIOLATION
$0
DOB (5)
IssuedViolationStatus
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#11118
DOB VIOLATION - ACTIVE
Feb 27, 2023CONSTRUCTION
FTM.1.MULT CRCKS ON EXP3 WALL(REAR WALL).2.FIRE ESCPE APPRDTO BE SVRLY RUSTD&THE CNNCTION TO THE EXTRIOR WALL APPEARD TO BE LOOS&UNSTBLE 3.EXP4 WALL HAD CRCKS,4.ROOF SAGGD,5.ROOF CHIMNY BRCKS CRCKD.IMMED COMPLY TO THE COMMISSIONER'S ORDER #341181 (020823FEU30104ZT) TO REPAIR THE BLDG UNDR PERMIT
#FEU30103ZT
DOB VIOLATION - ACTIVE
Feb 8, 2023CONSTRUCTION
FTM.1.MULT CRCKS ON EXP3 WALL(REAR WALL).2.FIRE ESCPE APPRD TO BE SVRLY RUSTD&THE CNNECTOIN TO THE EXTRIOR WALL APPEARD TO BE LOOS& UNSTBLE.3.EXP4 WALL HAD CRCKS,4.ROOF SAGGD,5.ROOF CHIMNY BRCKS CRCKD IMMED COMPLY TO THE COMMISSIONER'S ORDER #341181(020823FEU30104ZT)TO REPAIR THE BLDG UNDR PERMIT
#FEU30104ZT
DOB VIOLATION - ACTIVE
May 15, 1998CONSTRUCTION

#01J2
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#30795
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
HPD (4) · C 1 · B 2 · A 1
IssuedClassViolationCorrect by
Jul 3, 2008C§ 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES -2 STY. APT. 1 BATHROOM AND KITCHENJul 9, 2008
Jul 3, 2008A§ 27-2041 ADMIN. CODE: PROVIDE A PEEP HOLE IN ENTRANCE DOOR OF THE DWELLING UNIT SO LOCATED AS TO PERMIT A PERSON INSIDE THE DWELLING UNIT TO VIEW ANY PERSON OUTSIDE ENTRANCE DOOR 2ND & 3RD STY APTS.Oct 6, 2008
Jul 3, 2008B§ 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICK TREAD ENTRANCE TO BUILDING FRONTAug 7, 2008
Jul 3, 2008B§ 27-2032, 2034 ADNIM. CODE: DISCONTINUE USE OF ILLEGAL SPACE AND/OR HOT WATER HEATER AND PROVIDE FILED FOR & APPROVED HEATER WHICH OBTAINS COMBUSTION AIR DIRECTLY FROM OUTSIDE THE BUILDING OR APPROVED CENTRAL SYSTEM WATER HEATER AT KITCHEN, 3RD STORY APT. GAS.Aug 7, 2008