Bronx · Block 4905 · Lot 500 · 10466

1925 Schieffelin Avenue

3 floors · 143,260 sq ft · built 1954 · class W1 · owner of record: Nyc Department Of Education

20open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
190dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 69 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 143,260 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 190 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 190 days
Annual filing
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 434 days
Next cycle year 2027
Energy audit and retro-commissioning (2035) Likely applies
Local Law 87 · Calendar year 2035
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 4905). Agency page

Dec 31, 2035
in 3356 days
Next due 2035
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-13 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (13)
IssuedViolationHearingBalance
Apr 3, 2026Construction CLASS - 2
RE-ISSUE #35719807X. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT ROOF LEVEL, SPALLING CRUMBLING AND CRACKING PLASTER ONINTERIOR WALLS AND CEILING AT STAIRCASE "C" BULKHEAD. REMEDY: REPAIR A
#35722449M
May 15, 2026
POP/IN-VIO
$0
Apr 3, 2026Construction CLASS - 2
RE-ISSUE #35719803Z. EXIT DOOR NOT SELF-CLOSING . NOTED: ON THE 1ST FLOOR, EXTERIOR "EXIT 7" DOES NOT SELF-CLOSE WHEN TESTED. REMEDY: REPAIR/REPLACE DOOR.
#35727227J
May 15, 2026
POP/IN-VIO
$0
Apr 3, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: FIRE-PROOF DOORS DO NOT SELF-CLOSE PROPERLY WHEN TESTED AT AUDITORIUM MAIN DOORS IN BASEMENT. CLASSROOM DOORS DO NOT SELF-CLOSE PROPERLY AT 3RD FLR-
#35727229N
May 15, 2026
POP/IN-VIO
$0
Apr 3, 2026Construction CLASS - 2
RE-ISSUE #35719805M. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: ROOFS WATER PROOF MEMBRANE BLISTERING WITH TRAPPED AIR POCKETS THROUGHOUT SEVERAL AREAS. REMEDY: REPAIR AND/OR REPLACE.
#35727228L
May 15, 2026
POP/IN-VIO
$0
Apr 3, 2026Construction CLASS - 2
RE-ISSUE #35719804K. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PERBC 1006.1; 27-381. NOTED: EMERGENCY LIGHTS NOT OPERATIVE WHEN TESTED A
#35727226H
May 15, 2026
POP/IN-VIO
$0
Apr 3, 2026Construction CLASS - 2
RE-ISSUE #35719808H. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: HANDRAIL AT EXIT 3 AND 4 "EXTERIOR STEPS WAS LOOSE ALONG WITH ITS POST AND WOBBLING APPROX: 4" RAISES FALL/TRIP HAZARD TO STEP
#35722448K
May 15, 2026
POP/IN-VIO
$0
Apr 3, 2026Construction CLASS - 2
RE-ISSUE #35719806Y. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT ROOF LEVEL, MASONARY PARAPET WALLS HAVE ERODED MORTAR JOINTS THROUGHOUT SCATTERED LOCATIONS. ADDITIONALLY FULL HEIGHT VERTIC
#35727225X
May 15, 2026
POP/IN-VIO
$0
Jun 30, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED ROOFS WATER PROOF MEMBRANE BLISTERING WITH TRAPPED AIR POCKETS THROUGHOUT SEVERAL AREAS. REMEDY: REPAIR AND/OR REPLACE.
#35719805M
Sep 5, 2025
POP/IN-VIO
$0
Jun 30, 2025Construction CLASS - 2
EXIT DOOR NOT SELF-CLOSING. NOTED EXTERIOR DOORS AT EXIT #2 AND 8 NOT SELF-CLOSING PROPERLY. AUDITORIUM EXIT DOOR LEFT OF STAGE WAS NOT OPENING AT ALL. EXIT #2 AND 7 INTERIOR SMOKE DOORS WERE RACKED. REMEDY: RE
#35719803Z
Sep 5, 2025
POP/IN-VIO
$0
Jun 30, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED HANDRAIL AT EXIT 3 AND 4 EXTERIOR STEPS WAS LOOSE ALONG WITH ITS POSTS AND WABBLING APPROX 4". ROSES FALLING/TRIPPING HAZARD TO STEP USERS. REMEDY: R
#35719808H
Sep 5, 2025
POP/IN-VIO
$0
Jun 30, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED AT ROOF LEVEL, MASONRY PARAPET WALLS HAVE ERODED MORTAR JOINTS THROUGHOUT SCATTERED LOCATIONS. ADDITIONALLY FULL HEIGHT VERTICAL CRACK IN PARAPET WAL
#35719806Y
Sep 5, 2025
POP/IN-VIO
$0
Jun 30, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED SPALLING,CRUMBLING AND CRACKING PLASTER ON INTERIOR WALLS AND CEILINGS AT STAIRC BULKHEAD, CLASSROOM #319 AND #206 DUE TO WATER PENETRATING FROM EXTE
#35719807X
Sep 5, 2025
POP/IN-VIO
$0
Jun 30, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1; 27-381. NOTED EMERGENCY LIGHTS NOT OPERATIVE WHEN TESTED AT: 2ND FL GYM BOX #29
#35719804K
Sep 5, 2025
POP/IN-VIO
$0
DOB (2)
IssuedViolationStatus
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#07354
DOB VIOLATION - ACTIVE
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#07355
DOB VIOLATION - ACTIVE
DOB NOW Safety (5)
IssuedViolationStatus
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2018 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2018 External Inspection Affirmation of Correction for LP Device
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 23, 2026, 1:29 PM ET. BBL 2049050500.