2 floors · 3 apartments · 3,934 sq ft · built 1910 · class C0 · owner of record: Citimortgage, Inc.
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2009-10-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 64 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 64 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 80 days | Annual |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 429 days | Next cycle year 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Feb 20, 2024 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER - INTERIOR COLLAPSE FROM THE ROOF LEVEL TO THE CELLAR LEVEL. EXTERIOR WALL SHOWS OUTWARD DEFLECTION. PREMISES HAD BEEN SEALED WITH PYLWOOD AND PADLOCKS FO #39106397X | May 3, 2024 DEFAULT | $12,500 |
| Sep 18, 2020 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION#35467993K ISSUED ON 03/18/20 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102.01.FAILURE TO MAINTAIN BLDG #35426738M | Nov 20, 2020 DEFAULT | $3,125 |
| Mar 18, 2020 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES. NOTE: AT TIME OF INSPECTION OBSERVED AT EXP#/FRONT STAIRWAY LEADING TO 1ST FL LEVEL IS IN DISREPAIR. THE BRICK & ,ASONRY STAIRWAY HAS SEVERAL CRACKS,POROUS AREAS #35467993K | Dec 4, 2020 DEFAULT | $25,000 |
| Jan 4, 2020 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES. NOTE: AT TIME OF INSPECTION OBSERVED AT EXP#1 STAIRWAY LEADING TO 1ST FL LEVEL IS IN DISREPAIR. THE BRICK & MASONRY STAIRWAY HAS SEVERAL CRACKS,POROUS AREA,MISSI #35467607N | Feb 21, 2020 DEFAULT | $25,000 |
| Nov 15, 2019 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG WALLS & APPURTENANCES AT FRONT STAIRS TO ENTRY DOOR CRACKED,LOOSE MISSING & BULGING. REMEDY: REPAIR OR REPLACE. #35454868Z | Jan 3, 2020 DEFAULT | $12,500 |
| Sep 16, 2019 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING WALLS AND OR APPURTANCES AT FRONT STAIRS OF HOME BRICKS BUILDING,STEP CRACK,LOOSE MORTAR.REMEDY:REPAIR,REPLACE,MAKE SAFE. #35442859Z | Nov 1, 2019 DEFAULT | $12,500 |
| Sep 11, 2019 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER NOTED AT TIME OF INPSETCION I OBSERVED AT EXPOSURE #1 FRONT ENTRNACE EXTERIOR STAIRS IN A STATE OF DISREPAIR WITH HOLES AND CRACKS THROUGHOUT AT ROOF LEVLE #35447653X | Nov 1, 2019 DEFAULT | $12,500 |
| Jul 18, 2019 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES- @ FRONT STAIRS OF HOME. BRICKS BUILDING OUTWARD. STEP CRACKS. LOOSE MOTAR. STAIRS NOT IN GOOD SHAPE. REMEDY: MAINTAIN BUILDING WALLS. #35442147K | Sep 6, 2019 DEFAULT | $25,000 |
| Jun 20, 2019 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. EXTERIOR STAIRS IN A STATE OF DISREPAIR WITH HOLES AND CRACKS THROUGHOUT. AT ROOF LEVEL THE SIDING IS MISSING IN MULTIPLE AREAS EXPOSING BRICK UNDERNEATH. #39004381Y | Aug 16, 2019 DEFAULT | $6,250 |
| May 9, 2019 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING WALLS & APPURTENANCES @FRONT OF HOME(INSONRY) STAIRS CRACKED, BROKEN AND PULLING APART.REM: COMPLY WITH CODE. #35415096X | Jul 19, 2019 DEFAULT | $12,500 |
| Feb 14, 2019 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING WALL(S) APPURTENANCES NOTED:@TIME OF INSPECTION I OBSERVED FRONT OF BUILDING MASONRY STAIRS BROKEN AND CRACK INVARIOUS LOCATIONS AND PULLING AWAY MASONERY STAIRS MISSING 7 IN STATE #35386431Y | May 17, 2019 DEFAULT | $12,500 |
| Dec 7, 2018 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING WALLS AND APPURTENANCES AT FRONT BUILDINGBEING MASONRY STAIRS MASONRY BRICKS MISSING IN STATE OF DISREPAIR AHDNING CONCRETE BREAKING.REM:REPAIR THE ROOF MAINTAIN EXTERIOR BUILDING W #35370046L | Feb 1, 2019 DEFAULT | $12,500 |
| Oct 10, 2018 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCE. AT THE TIME OF INSPECTION & OBSERVED AT EXP#1 FRONT BLDG BRICKS/MASONRY PLATFORM STAIRS ON 2ND LANDING CAPING EDGE IS LANDING MISSING CONCRETE SLAB,STEP ARE SEPER #35361783R | Nov 30, 2018 DEFAULT | $25,000 |
| Sep 8, 2018 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES-AT FRONT OF BLDG MASONARY STAIRS PLATFORM ARE SEPERATED FROM THE BRICK WORK. BRICK ARE BUDGING OUTWARD @ EXP#4. ALSO MORTAR IS MISSING AT VARIOUS AREAS ON THE STA #35361301P | Nov 2, 2018 DEFAULT | $25,000 |
| Jul 20, 2018 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES.NOTED:AT FRONT OF BUILDING MASONARY STAIRS PLATFORM HAS A HOLE 12LX8W AND SOME STEPS SEPERATING AND BRICKS FALLING OUT.REM:MAINTAIN EXTERIOR BUILDING WALLS #35333382H | Sep 21, 2018 DEFAULT | $25,000 |
| Jun 9, 2018 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING WALL OR APPURTENANCES. NOTE: AT FRONT OF BLDG MASONRY AND BRICK STAIRS IS IN DISREPAIR SUCH AS LARGE HOLD IN STAIRS PLATFORM APPRX 12"L X 8"W. LARGECRACKS AT VARIOUS LOCATIONS,BRICK #35332828Z | Aug 3, 2018 DEFAULT | $12,500 |
| Jun 9, 2018 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG WALL OR APPURTENANCES. NOTED: AT FRONT OF BLDG MASONRY AND BRICK STAIRS IS IN DISREPAIR SUCH AS A LARGE HOLE IN STAIRS PLATFORM APPRX 12"L X 8"W, LARGE CRACKS AT VARIOUS LOCATION,BRICKS #35332827R | Aug 3, 2018 DEFAULT | $12,500 |
| Issued | Violation | Status |
|---|---|---|
| Feb 20, 2024 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER - INTERIOR COLLAPSE FROM THE ROOF LEVEL TO THE CELLAR LEVEL. EXTERIOR WALL SHOWS OUTWARD DEFLECTION. FULL VACATE TO PREMESIS ALONG WITH ENGINEER'S REPORT REQUIRED #24-00399 | DOB VIOLATION - ACTIVE |
| Jul 11, 2023 | UNSAFE BUILDINGS #2013/23 | DOB VIOLATION |
| Sep 2, 2020 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #02637 | DOB VIOLATION - ACTIVE |
| Sep 2, 2020 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #02636 | DOB VIOLATION - ACTIVE |
| Feb 5, 2020 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00378 | DOB VIOLATION - ACTIVE |
| Dec 11, 2019 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00262 | DOB VIOLATION - ACTIVE |
| Dec 11, 2019 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00263 | DOB VIOLATION - ACTIVE |
| Oct 17, 2019 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00537 | DOB VIOLATION - ACTIVE |
| Sep 19, 2019 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00223 | DOB VIOLATION - ACTIVE |
| Aug 22, 2019 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00226 | DOB VIOLATION - ACTIVE |
| Jun 26, 2019 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00553 | DOB VIOLATION - ACTIVE |
| Mar 6, 2019 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00454 | DOB VIOLATION - ACTIVE |
| Jan 9, 2019 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00283 | DOB VIOLATION - ACTIVE |
| Nov 28, 2018 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00210 | DOB VIOLATION - ACTIVE |
| Oct 31, 2018 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00348 | DOB VIOLATION - ACTIVE |
| Sep 5, 2018 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00210 | DOB VIOLATION - ACTIVE |
| Sep 5, 2018 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00209 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 2, 2020 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 2, 2020 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 5, 2020 | AEUHAZ FTC-AEU-HAZ | Active |
| Dec 11, 2019 | AEUHAZ FTC-AEU-HAZ | Active |
| Dec 11, 2019 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 17, 2019 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 19, 2019 | AEUHAZ FTC-AEU-HAZ | Active |
| Aug 22, 2019 | AEUHAZ FTC-AEU-HAZ | Active |
| Jun 26, 2019 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 6, 2019 | AEUHAZ FTC-AEU-HAZ | Active |
| Jan 9, 2019 | AEUHAZ FTC-AEU-HAZ | Active |
| Nov 28, 2018 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 31, 2018 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 5, 2018 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 5, 2018 | AEUHAZ FTC-AEU-HAZ | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)