Brooklyn · Block 2575 · Lot 8 · 11222

192 Greenpoint Avenue

4 floors · 8 apartments · 5,800 sq ft · built 1928 · class C1 · owner of record: 192 Greenpoint Avenue Llc

6open violations
$15,000ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 65 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 65 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 81 days
Annual
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 796 days
Next cycle year 2028
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-08-04 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (3) · $15,000 owed
IssuedViolationHearingBalance
Sep 23, 2026Construction CLASS - 1
UNLAWFUL ACTS. FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDERS TO OBTAIN WORK PERMITS AS PER VIOLATION #39160255H. NO PERMITS ISSUED FOR THE DEMOLITION AND INSTALLATION OF PARTITION WALLS ON PROPERTY., COMPLY
#39205298Y
Dec 2, 2026
PENDING
$2,500
Sep 11, 2025Construction CLASS - 1
AT TIME OF INSPECTION OBSERVED, NEW PARTITIONS BEING CREATED AND DEMOLISHED OF INTERIOR SPACE. ECB ISSUED FOR CONSTRUCTION WORK WITHOUT A PERMIT., OBTAIN PERMIT
#39160255H
Apr 17, 2026
ADMIT/IN-VIO
$0
Sep 11, 2025Construction CLASS - 1
AT TIME OF INSPECTION OBSERVED, CONSTRUCTION WORK FAILING TO SAFEGUARD PUBLIC. STRUCK BY HAZARDOUS CONDITIONS ARE CREATED BY IMPROPER PUMPJACK SCAFFOLDING ACROSS SIDEWALK. ECB ISSUED FOR ENDANGERING THE PUBLIC.
#39160112K
Mar 15, 2027
DEFAULT
$12,500
DOB (0)

None open.

DOB NOW Safety (1)
IssuedViolationStatus
Jan 8, 2026Gas Piping - LL152 FTF-PL-PER
Cycle 2, Sub-cycle A (premises is in Community District 1)
Active
HPD (3) · C 0 · B 2 · A 1
IssuedClassViolationCorrect by
Oct 16, 2024AApt 1L · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION DROP CEILING INSTALLED IN THE ENTIRE APARTMENT LOCATED AT APT 1L, 1st STORY, APARTMENT AT SOUTHJan 19, 2025
Jan 16, 2018BApt 1R · § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... 4 SQ. FT. AT WEST AND SOUTH WALLS IN THE 3rd BATHROOM FROM NORTH LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTFeb 20, 2018
Jan 16, 2018BApt 1R · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTFeb 20, 2018

Issued in the last 120 days

DateSourceWhatNow
Sep 23, 2026ECBConstruction: UNLAWFUL ACTS. FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDERS TO OBTAIN WORK PERMITS AS PER VIOLATION #39160255H. NO PERMITS ISSUED FOR THE DEMOLITION AND INSTALLATION OF PARTITION WALLS ON PROPERTY., COMPLYOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 27, 2026, 8:37 AM ET. BBL 3025750008.

Look up another building