9 floors · 69 apartments · 60,247 sq ft · built 2025 · class D1 · owner of record: 1916 Longfellow Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 66 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Energy audit and retro-commissioning (2026) Likely applies Local Law 87 · Calendar year 2026 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 3016). Agency page | Dec 31, 2026 in 66 days | Due this year |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 66 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 82 days | Annual |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page | Feb 21, 2027 in 118 days | No Cycle 10 report on record yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 60,247 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 187 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 187 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| May 9, 2026 | Unknown CLASS - 2 3301.5 UNSAFE CONDITIONS- AT MULTIPLE LOCATIONS I ACTIVE JOBSITE STAIRCASE, OBSERVED LIVE ELECTRICAL COMPONENTS WRAPPED/CONNECTED TO STANDPIPE SYSTEM. THIS CREATES A HAZARDOUS ELECTRICAL CONDITION DUE TO STANDP #39553937M | Jan 14, 2027 | $2,500 |
| May 9, 2026 | Construction CLASS - 1 OBSERVED ACTIVE STUCCO OPERATIONS ON SHED OF JOBSITE AT EXPOSURES 1&4 WITH MATERIAL STORAGE ON SHED. REVIEW OF DOB RECORDS SHOW THAT THERE IS A PSWO IN PLACE STATING STOP ALL WORK ON SHED DECK ISSUED 4-11-2026. #39553936K | Jan 14, 2027 | $10,000 |
| May 9, 2026 | Unknown CLASS - 2 3303.7.7.2 STANDPIPES- OBSERVED STANDPIPE INSTALLED IN ACTIVE 9 STORY JOBSITE FROM 1ST FLOOR TO ROOF. THE STAND PIPE IS NOT IN A STATE OF READINESS. NO RED PAINT AHS BEEN APPLIED TO STANDPIPE AND UPON REQUEST F #39553935Z | Jan 14, 2027 | $2,500 |
| Mar 25, 2026 | Construction CLASS - 1 9 STORY NEW BUILDING ACTIVE SITE.INTERIOR ELEVATOR NOT MAINTAINED IN A STATE OF READINESS FOR SAFE OPERATION, CONSTITUTING A HAZARDOUS CONDITION TO WORKER'S/VISITOR'S & FIRST RESPONDERS. EQUIPMENT NOT OPERATION #39552188J | Dec 11, 2026 | $2,500 |
| Dec 22, 2025 | Unknown CLASS - 1 AT TIME OF INSPECTION OF A 9 STORY BUILDING APPROXIMATELY 84 FT. NO HOIST WAS IN PLACE IN STATE OF READINESS. FAILURE TO PROVIDE SAFE ACCESS AND EGRESS TO ELEVATED WORK AREAS CREATES AN UNSAFE CONDITION AT TIME #39548354Y | Sep 3, 2026 IN VIOLATION | $0 |
| Aug 25, 2020 | Unknown CLASS - 1 FAILURE TO PROVIDE PRE-SHIFT MEETING AT TIME OF MY INSPECTION OF AN ACTIVE DEMOLITION JOBSITE WITH 5 WORKERS ONSITE.UPON REQUESTING PRESHIFTMEETING FOR WORKER NONE WAS PROVIDED AT TIME OF MY INSPECTION.PRESHIFT #35499938Y | Nov 12, 2021 IN VIOLATION | $5,000 |
| Aug 25, 2020 | Unknown CLASS - 1 FAILURE TO MAINTAIN A RECORD OF ORIENTATIONS AT WORKSITE AT TIME OF MYINSPECTION OF AN ACTIVE-DEMOLITION JOBSITE WITH 5 WORKERS.I REQUESTED TO SEE SITE SAFETY ORIENTATIONS FOR WORKERS AND NONE WAS PROVIDED TO M #35499940N | Jul 16, 2021 DEFAULT | $12,500 |
| Jul 10, 2020 | Construction CLASS - 1 FAILURE TO SAFEGUARD ALL PERSOSN & PROPERTY AT TIME OF MY INSPECTION FO A DEMO 2 STORY BUILDINGI OBSERVED NO OVERHEAD PROTETCION AT NEIGHBORING BUILDING EXP #2 AND AT EXP #1,4 SIDEWALKS AS PER SECTION (3307,6) #35481471Y | Mar 12, 2021 IN VIOLATION | $10,000 |
| Jul 10, 2020 | Construction CLASS - 2 PEDESTRIAN PROTETCION DOES NOT MEET CODE AT TIME OF MY INSPECTION OF A 2 STORY BUILDING OBSERVED A CONSTRUCTION FENCE AT A DEMO SITE CONSTRUCTIONF ENCE IS INADEQUATE AND SHOULD BE FULL ENCLOSED I OBSERVED A 3 #35481472X | Mar 12, 2021 IN VIOLATION | $2,400 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Aug 12, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Aug 12, 2026 | DOB Safety | AEUHAZ: | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)