5 floors · 16 apartments · 9,205 sq ft · built 1910 · class C4 · owner of record: Nyc Department Of Homeless Services
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 44 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 44 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 60 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 409 days | Next cycle year 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Nov 14, 2024 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE. OBSERVED HOLE PENETRATIONS IN BASEMENT IN TRASH CHUTE ROOM. INCASE FOR EMERGENCY #39130740Y | Nov 21, 2024 POP/IN-VIO | $0 |
| Nov 14, 2024 | Unknown CLASS - 2 I OBSERVED IN THE FIRST FLOOR MAINTENANCE ROOM NO GFCI PROTECTION WITHIN 6 FEET OF A SINK., INSTALL GFC1 PROTECTION; PROVIDE GFCI PROTECTION. #39130250L | Nov 21, 2024 POP/IN-VIO | $0 |
| Nov 14, 2024 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED HANDRAIL AT BASEMENT LEVEL DETRACTED FROM WALL. BROKEN COBBLE STONE ON ROOF AS WELL. THESE VIOLATIONS MAY BE A TRIPPING HAZARD., REPAIR AND/REPLAC #39130741X | Nov 21, 2024 POP/IN-VIO | $0 |
| Apr 5, 2023 | Unknown CLASS - 2 I OBSERVED IN THE MAINTENANCE CLOSET THE RECEPTACLE WITHIN 6 FEET OF THE SINK NOT OF THE GFCI TYPE., INSTALL GFC1 PROTECTION #39083146M | Apr 27, 2023 POP/IN-VIO | $0 |
| Jan 4, 2023 | Construction CLASS - 2 -OBSERVED: AT CELLAR LEVEL, FRONT EXIT DOOR AND FIRST FLOOR MAIN ENTRANCE DOOR DO NOT CLOSE PROPERLY WHEN INSPECTED, REPAIR/REPLACE DOOR #39076997P | Jan 10, 2023 POP/IN-VIO | $0 |
| Jan 4, 2023 | Construction CLASS - 2 OBSERVED: AT CELLAR LEVEL, STORAGE ROOMS, RETAINING WALL SHOWS DETERIORATION, PEELING PAINT, MOLD, AND LOSS MORTAR, DUE,WATER PENETRATION AND SEVERAL WINDOWS WERE CLOSED WITH CMU BLOCKS, LEAVING THE SPACES WITH #39076998R | Jan 10, 2023 POP/IN-VIO | $0 |
| Jan 4, 2023 | Construction CLASS - 2 OBSERVED GAS PIPING IN THE BASEMENT HAS AREAS OF RUST AND CORROSION. AS PER PC 102.3 INSTALLATIONS, BOTH EXISTING AND NEW, AND PARTS THEREOF SHALL BE MAINTAINED IN PROPER OPERATING CONDITION IN ACCORDANCE WITH #39076964Z | Jan 10, 2023 POP/IN-VIO | $0 |
| Jan 4, 2023 | Construction CLASS - 2 OBSERVED: AT ROOF LEVEL, STAIRCASE EXTERIOR WALLS CRACKED NEAR EXIT DOOR., MAINTAIN EXTERIOR BUILDING WALL #39076999Z | Jan 10, 2023 POP/IN-VIO | $0 |
| Apr 15, 2022 | Construction CLASS - 2 - AT FIRST FLOOR, BACK SIDE ,METAL STAIRS OF THE EVACUATION ROUTE ARE DAMAGED BY DETERIORATION AND CORROSION., REPAIR AND/OR REPLACE #39060430H | Apr 19, 2022 POP/IN-VIO | $0 |
| Nov 5, 2021 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.LACK OF EMERGENCY LIGHTING FOR EXITS EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27--542 OBSERVED 6 STORY BUILDING WITH FRONT EXITS AND BACK EXITS W/ #35631754P | Feb 17, 2022 POP/IN-VIO | $0 |
| Mar 22, 2019 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTED: OBSERVEDCRACKS AND BULGING CONCRETE ALONG THE LENGTH OF THE RETAINING WALL AT SOUTH ELEVATION (EXP#1) RMDY: MAINTAIN EXTERIOR BUILDING WALL. #35383818P | May 30, 2019 POP/IN-VIO | $0 |
| Sep 28, 2018 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER:NO FIRE STOPPINGPER BC712.3;27-345. NOTED:AT CELLAR, IN SUPPLY AREA, THERE IS A HOLE APPROXIMATELY 6' SQ FT AT CEILING EXPOSING JOISTS AND I-BEAMS ELIMINATI #35361395P | Nov 29, 2018 POP/IN-VIO | $0 |
| Sep 28, 2018 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTED:AT ROOF, COPING STONES ARE LOOSE AND MISSING IN VARIOUS LOCATIONS. ALSO, AT FRONT AREAWAY, BELOW BUILDING ENTRANCE STAIRS, RETAINING WALL CRACKED IN #35361394N | Nov 29, 2018 POP/IN-VIO | $0 |
| Mar 23, 2018 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING WALL(S)OR APPURTENANCES.NOTED:OBSERVED ATFRONT OF BUILDING THE RETAINING WALL HAVE CRACKS THROUGHOUT SPALLING CONCRETER NEXT TO STAIRS THAT LEADS TO CELLAR,ALSO.LOBBYS REAR EXIT MET #35325703J | May 31, 2018 POP/IN-VIO | $0 |
| Aug 22, 2017 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED IN BSMT ANUNSERVICEABLE ELECTRICALLY POWERED GARBAGE COMPACTOR.MECHANICAL PARTS & ELECTRICAL COMPONENTS ARE EXTREMELY CORRODED DUE TO LACK OF MAINTENA #35290277Z | Oct 19, 2017 POP/IN-VIO | $0 |
| Aug 22, 2017 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTED: OBSERVED AT FRONT OF BUILDING, RETAINING WALL HAS HORIZONTAL CRACKS ACROSS THE LENGTH OF WALL, SPALLING CONCRETE NEAR STAIRS TO BASEMENT. REM: MAINT #35290005P | Dec 21, 2017 POP/IN-VIO | $0 |
| Aug 22, 2017 | Plumbing CLASS - 1 FGC 411.1 RESIDENTIAL GAS FLEX USED ON COMMERCIAL EQUIPMENT.OBSERVED ON 08/22/17 @ABOVE ADDRESS RESIDENTIAL GAS FLEX ON COMMERCIAL LAUNDRY EQUIPMENT MUST BE HAND PIPE.*PHOTO TAKEN* REM:COMPLY W/SUMMONS. #35289647Z | Dec 21, 2017 POP/IN-VIO | $0 |
| Mar 27, 2017 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER. OBSERVED ON 3-27-17 IN BASEMENT FIRE STOP MATERIAL IS COVERING GAS PIPE. REMEDY: REPAIR & OR REPLACE. #35235747M | Apr 27, 2017 POP/IN-VIO | $0 |
| Mar 27, 2017 | Plumbing CLASS - 1 SEC. 401.1 GAS PIPING NOT LABELED. ON 3-27-17 IN BASEMENT/CELLAR LEVELAT ABOVE ADDRESS GAS PIPING NOT LABELED. REMEDY: COMPLY W/SUMMONS. #35235749X | Apr 27, 2017 POP/IN-VIO | $0 |
| Mar 27, 2017 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED ON 3-27-17IN BASEMENT/CELLAR AT ABOVE ADDRESS JIM CAPS ARE INSTALLED ON CAST IRON FITTINGS. MUST BE HAND CAPPED. REMEDY: REPAIR &/OR REPLACE. #35235748Y | Apr 27, 2017 POP/IN-VIO | $0 |
| Sep 16, 2016 | Construction CLASS - 2 FAILURE TO MAINTAIN IN CODE COMPLIANT MANNER. DEFECTS NOTED:RETAINING WALL AT FRONT OF PREMISES HAS APPRX 2"WIDE HORIZONTAL CRACK ALONG THE LENGTH OF THE WALL.RMDY:COMPLY WITH NOTICE OF VIOLATION. #35207842M | Nov 17, 2016 POP/IN-VIO | $0 |
| Sep 16, 2016 | Plumbing CLASS - 1 MISC VIOL. OBSERVED ON 9/16/16 AT 10:20AM IN LAUNDRY ROOM RESID GAS FLEX ON COIN OP COMM GAS DRYER. PHOTOS TAKEN. RMDY: COMPLY WITH NOV. #35208030L | Nov 17, 2016 POP/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Feb 27, 2001 | LOCAL LAW 62/91 - BOILERS #04968 | DOB VIOLATION - ACTIVE |
| Feb 7, 2000 | LOCAL LAW 62/91 - BOILERS #05137 | DOB VIOLATION - ACTIVE |
| Mar 16, 1999 | LOCAL LAW 62/91 - BOILERS #05121 | DOB VIOLATION - ACTIVE |
| May 4, 1998 | LOCAL LAW 62/91 - BOILERS #07641 | DOB VIOLATION - ACTIVE |
| Aug 29, 1995 | LOCAL LAW 62/91 - BOILERS #09985 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jan 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle D (premises is in Community District 11) | Active |
| Feb 27, 2001 | Boiler LL6291 | Active |
| Feb 7, 2000 | Boiler LL6291 | Active |
| Mar 16, 1999 | Boiler LL6291 | Active |
| May 4, 1998 | Boiler LL6291 | Active |
| Aug 29, 1995 | Boiler LL6291 | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 17, 2026, 2:57 AM ET. BBL 1016280030.