2 floors · 2 apartments · 2,400 sq ft · built 1931 · class S2 · owner of record: Eaaa Inc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Annual property registration Check HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 291 days | Registered through 2027-09-01 |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 412 days | Next cycle year 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Dec 10, 2025 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH DEPARTMENT OF BUILDING FOR SUMMONS 35643120L., FILE A CERTIFICATE OF CORRECTION #39169908R | Feb 17, 2026 DEFAULT | $6,250 |
| Jan 28, 2022 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTE: AT EXP#2 ON SIDE OF BLDG THE FIRE ESCAPES IN DISREPAIR W/BROKEN(RUNGS)& LOTS OF RUST OF FIRE ESCAPE LADDER. REMEDY: REPAIR &/OR REPLACE. #35643120L | Sep 12, 2023 IN VIOLATION | $3,125 |
| Nov 10, 2021 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER.2FIREESCAPES ON REAR SIDE OF BLDG@2FL IN STATE OF DISREPAIR W/BROKEN RUNGS&RUSTED&DETERIORATING.REPAIR &/OR REPLACE&SUBMIT C/C #35578563M | Sep 12, 2023 IN VIOLATION | $1,250 |
| Sep 14, 2021 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER NOTED:@EXP4 FIRE ESCAPE LADDERS IN STATE OF DISREPAIR W/RUSTED,ROTTED&REAR ONE MISSING/BROKEN RUNGS&LANDING METAL FRAME.REPAIR &/OR REPLACE #35591834L | Dec 14, 2021 DEFAULT | $12,500 |
| Apr 15, 2021 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER.NOTED:OBSERVED ON LEFT SIDE OF BLDG@EXP2,FIRE ESCAPE LADDER IN DISREPAIR W/PART OF PLATFORMDETACHED&PART OF LADDER ROTTED.REPAIR &/OR REPLACE. #35553717P | Jul 6, 2021 DEFAULT | $12,500 |
| Jan 13, 2021 | Construction CLASS - 1 FIRE ESCAPE LADDER ACCESS AREA ON LEFT SIDE OF THE BUILDING IS OBSTRUCTED WITH WOOD BRACES FROM THE CONSTRUCTION FENCE NEXT DOOR. ALSO THE AREA IS BLOCKED WITH 2X4 WOOD STUDS AND CHAIRS AT TIME OF INSPECTION. F #39034814H | Sep 5, 2023 IN VIOLATION | $1,250 |
| Jan 13, 2021 | Construction CLASS - 1 FIRE ESCAPE LADDER ON LEFT SIDE OF THE BUILDING IS IN DISREPAIR CONDITION. IT IS RUSTED AND COUPLE OF METAL PIECES ON THE STANDING PLATFORM IS 90% DETACHED FROM ITS FRAME. SOME STEPS ON THE LADDER ALSO DETACHED #39034815J | Sep 5, 2023 IN VIOLATION | $625 |
| Issued | Violation | Status |
|---|---|---|
| Apr 27, 2022 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00435 | DOB VIOLATION - ACTIVE |
| Feb 2, 2022 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00403 | DOB VIOLATION - ACTIVE |
| Dec 22, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00924 | DOB VIOLATION - ACTIVE |
| Jul 7, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00528 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Apr 27, 2022 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 2, 2022 | AEUHAZ FTC-AEU-HAZ | Active |
| Dec 22, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Jul 7, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 14, 2026, 4:39 AM ET. BBL 4126700001.