92 apartments · 61,137 sq ft · built 2025 · class D3 · owner of record: Hp Cornaga Housing Development Fund Comp Any, Inc.
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 60 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 60 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 76 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 61,137 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 181 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 181 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 14 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 425 days | Next cycle year 2027 |
| Energy audit and retro-commissioning (2034) Likely applies Local Law 87 · Calendar year 2034 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 15564). Agency page | Dec 31, 2034 in 2982 days | Next due 2034 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 21, 2025 | Unknown CLASS - 1 3303.8 AT THE TIME OF MY INSPECTION OF A 9-STORY BUILDING, I OBSERVED THE STANDPIPE SYSTEM NOT MAINTAINED IN A STATE OF READINESS. AT THE 7TH TO 8TH FLOOR LEVELS, THE STANDPIPE WAS IN BLACK INSTEAD OF RED AS RE #39546205L | Feb 2, 2027 | $5,000 |
| Oct 21, 2025 | Unknown CLASS - 1 3301.2 AT THE TIME OF MY INSPECTION OF AN ACTIVE JOB SITE, I OBSERVED AT THE ROOF LEVEL OF THE 9TH FLOOR WORKERS PERFORMING CINDER BLOCK WORK WITH MISSING GUARDRAILS AROUND THE OPEN EDGES, CREATING A FALL HAZAR #39546202X | Feb 2, 2027 | $5,000 |
| Oct 21, 2025 | Unknown CLASS - 1 BC 3314.1AT THE TIME OF MY INSPECTION OF A 9-STORY BUILDING, I OBSERVED PIPE SCAFFOLD AT EXPOSURE #1 WITH MULTIPLE LOOSE PLANKS, UNSECURED BOARDS, MISSING PINS, AND AN UNSAFE SCAFFOLD IN THE ELEVATOR SHAFT WITH #39546206N | Feb 2, 2027 | $5,000 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Jan 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle D (premises is in Community District 14) | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 1, 2026, 9:50 PM ET. BBL 4155640040.