3 floors · 49,819 sq ft · built 2021 · class E9 · owner of record: 1906 Flushing Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 67 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 49,819 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 188 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 188 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1163 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Mar 23, 2022 | Construction CLASS - 1 WORK DOESNT CONFORM TO APPROVED CONST DOCS &OR APPROVED AMENDMENTS.ATOI ON ACTIVE JOBSITE,OBSERVED STRUCTURAL PLAN DOESNT INDICATE APRX10'HX20'X60' STEEL STRUCTURE ERECTED ON 2FL.STEEL STRUCTURE CONSISTS OF STR #35647818L | Jun 21, 2022 IN VIOLATION | $625 |
| Mar 23, 2022 | Construction CLASS - 1 3301.13.1 INADEQUATE SSP ATOI ON ACTIVE JOBSITE,OBSERVED SSP DOESNT INDICATE APRX10' IN DEPTH EXCAVATION,10' OF CONST FENCE@EXP4,AS WELL AS 10DETENTION TANKS 10' IN DIAMETER.SUPPORT OF EXCAVATION NOT PROVIDED F #35647819N | Jun 21, 2022 IN VIOLATION | $2,500 |
| Mar 23, 2022 | Construction CLASS - 1 BC3301.1 FAILURE TO PROVIDE FALL PROTECTION ATOI ON ACTIVE JOBSITE,OBSERVED CONST WORKER CUTTING PRECAST SLAB BY USING GASPOWERED CUTTING SAW@EDGE OF UNPROTECTED SLAB OF 2FL 12' ABOVE GRND,NOT BEING TIEDOFF-NO #35647816H | Jun 21, 2022 IN VIOLATION | $2,500 |
| Dec 13, 2021 | Construction CLASS - 1 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS-NEEDLE BEAM NOT CONFORMING TO DESIGN DRAWING.AT TIME OF INSPECTION OBSERVED NEEDLE BEAM AT EXP #2 ONE NEEDLE BEAM MISSING ONE #35633161Z | Aug 2, 2022 IN VIOLATION | $2,500 |
| Dec 13, 2021 | Construction CLASS - 1 FAILURE TO COMPLY WITH MANUFACTURER SPECIFICATION-CUT FRAME USED ON SUPPORTED SCAFFOLD.AT TIME OF INSPECTION OBSERVED SUPPORTED SCAFFOLD AT EXP #4 USE CUT FRAME SCAFFOLD AT BOTTOM.ANY USE OF CUT FRAME CONTRARY #35633160R | Aug 2, 2022 IN VIOLATION | $2,500 |
| Dec 13, 2021 | Construction CLASS - 1 BC3314.2 THRU BC3314.20.FAILURE TO PROVIDE PROPER CONNECTION IN CODE COMPLIANT MANNER.AT TIME OF INSPECTION OBSERVED SUPPORTED SCAFFOLD AT EXP #3 #4 OUTRIGGER SCAFFOLD (THRUST OUT)ON THREE DIFFERENT LEVELS CONN #35633163M | Aug 2, 2022 IN VIOLATION | $2,500 |
| Dec 13, 2021 | Site Safety CLASS - 1 FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER 33-NO DETAIL DESIGN DRAWING FOR HOISTING/RIGGING ASSEMBLY AT ELEVATOR SHAFTS.AT TIME OF INSPECTION OBSERVED HOISTING RIGGING ASSEMBLY HOIST A #35633162K | Aug 2, 2022 IN VIOLATION | $1,250 |
| Jul 19, 2021 | Construction CLASS - 2 EXTERIOR WALLS ON EXPOSURE 2 FROM 1ST. TO 2ND. FLOOR WERE INSTALLED WITH 2" OUTBOARD RIGID INSULATION (R-10CI.) CONTRARY TO 3" CONTINUOUS INSULATION (R-15CI.) INDICATED ON COMCHECK AND EXTERIOR WALLS DETAILS AS #39044610P | Sep 7, 2021 STIPULATION/IN-VIO | $1,250 |
| Mar 25, 2021 | Construction CLASS - 1 FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURE OR TEMP CONST-NO GUARDRAILS.NOTE:@TIME OF MY INSP OF 3STYNB@2FL LEVEL UNDER CONST.I OBSERVEDWORKERS WORKING@2FL LEVEL SOME LOCATIONS NO GUARDRAILS SOME LOC #35551374N | Jun 15, 2021 IN VIOLATION | $67 |
| Mar 25, 2021 | Construction CLASS - 1 FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SEC REQUIREMENTS.NOTE:@TIME OF MY INSP OF 3STYNB@2FL LEVEL UNDER CONST,I OBSERVED ACTIVE JOBSITE.INADEQUATE HOUSEKEEPING FOUND ALL AROUND JOBSITE NOT MAINTAIN AS RE #35551373L | Jun 15, 2021 IN VIOLATION | $2,500 |
| Mar 25, 2021 | Construction CLASS - 2 FAILURE TO SAFEGUARD ALL PERSONS&PROPERTY AFFECTED BY CONST.NOTE:@TIMEOF MY INSP OF 3STYNB@2FL LEVEL UNDER CONST.I OBSERVED ACTIVE JOBSITE ADJ PROPERTY@EXP2@19-40FLUSHINGAVE EXTERIOR WALL CRACKS FOUND VERTICALL #35551372J | Jun 15, 2021 IN VIOLATION | $5,000 |
| Mar 25, 2021 | Site Safety CLASS - 1 CONST SUPER FAILED TO PERFORM DUTIES PERCODE.NOTE:@TIME OF MY INSP OF 3STYNB@2FL LEVEL UNDER CONST:I OBSERVED ACTIVE JOBSITE.COMPETENT PERSON PRESENT@JOBSITE JOBSITE VERY UNSAFE CONDITIONS NOT COMPLY W/SITE SAF #35551378K | Jun 15, 2021 IN VIOLATION | $10,000 |
None open.
None open.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 25, 2026, 3:15 PM ET. BBL 4033760001.