Queens · Block 3376 · Lot 1 · 11385

19-06 Flushing Avenue

3 floors · 49,819 sq ft · built 2021 · class E9 · owner of record: 1906 Flushing Llc

0open violations
$33,192ECB/OATH penalties owed
0HPD class C (immediately hazardous)
188dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 67 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 49,819 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 188 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 188 days
Annual filing
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1163 days
Next cycle year 2029

Open violations

ECB / OATH (12) · $33,192 owed
IssuedViolationHearingBalance
Mar 23, 2022Construction CLASS - 1
WORK DOESNT CONFORM TO APPROVED CONST DOCS &OR APPROVED AMENDMENTS.ATOI ON ACTIVE JOBSITE,OBSERVED STRUCTURAL PLAN DOESNT INDICATE APRX10'HX20'X60' STEEL STRUCTURE ERECTED ON 2FL.STEEL STRUCTURE CONSISTS OF STR
#35647818L
Jun 21, 2022
IN VIOLATION
$625
Mar 23, 2022Construction CLASS - 1
3301.13.1 INADEQUATE SSP ATOI ON ACTIVE JOBSITE,OBSERVED SSP DOESNT INDICATE APRX10' IN DEPTH EXCAVATION,10' OF CONST FENCE@EXP4,AS WELL AS 10DETENTION TANKS 10' IN DIAMETER.SUPPORT OF EXCAVATION NOT PROVIDED F
#35647819N
Jun 21, 2022
IN VIOLATION
$2,500
Mar 23, 2022Construction CLASS - 1
BC3301.1 FAILURE TO PROVIDE FALL PROTECTION ATOI ON ACTIVE JOBSITE,OBSERVED CONST WORKER CUTTING PRECAST SLAB BY USING GASPOWERED CUTTING SAW@EDGE OF UNPROTECTED SLAB OF 2FL 12' ABOVE GRND,NOT BEING TIEDOFF-NO
#35647816H
Jun 21, 2022
IN VIOLATION
$2,500
Dec 13, 2021Construction CLASS - 1
WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS-NEEDLE BEAM NOT CONFORMING TO DESIGN DRAWING.AT TIME OF INSPECTION OBSERVED NEEDLE BEAM AT EXP #2 ONE NEEDLE BEAM MISSING ONE
#35633161Z
Aug 2, 2022
IN VIOLATION
$2,500
Dec 13, 2021Construction CLASS - 1
FAILURE TO COMPLY WITH MANUFACTURER SPECIFICATION-CUT FRAME USED ON SUPPORTED SCAFFOLD.AT TIME OF INSPECTION OBSERVED SUPPORTED SCAFFOLD AT EXP #4 USE CUT FRAME SCAFFOLD AT BOTTOM.ANY USE OF CUT FRAME CONTRARY
#35633160R
Aug 2, 2022
IN VIOLATION
$2,500
Dec 13, 2021Construction CLASS - 1
BC3314.2 THRU BC3314.20.FAILURE TO PROVIDE PROPER CONNECTION IN CODE COMPLIANT MANNER.AT TIME OF INSPECTION OBSERVED SUPPORTED SCAFFOLD AT EXP #3 #4 OUTRIGGER SCAFFOLD (THRUST OUT)ON THREE DIFFERENT LEVELS CONN
#35633163M
Aug 2, 2022
IN VIOLATION
$2,500
Dec 13, 2021Site Safety CLASS - 1
FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER 33-NO DETAIL DESIGN DRAWING FOR HOISTING/RIGGING ASSEMBLY AT ELEVATOR SHAFTS.AT TIME OF INSPECTION OBSERVED HOISTING RIGGING ASSEMBLY HOIST A
#35633162K
Aug 2, 2022
IN VIOLATION
$1,250
Jul 19, 2021Construction CLASS - 2
EXTERIOR WALLS ON EXPOSURE 2 FROM 1ST. TO 2ND. FLOOR WERE INSTALLED WITH 2" OUTBOARD RIGID INSULATION (R-10CI.) CONTRARY TO 3" CONTINUOUS INSULATION (R-15CI.) INDICATED ON COMCHECK AND EXTERIOR WALLS DETAILS AS
#39044610P
Sep 7, 2021
STIPULATION/IN-VIO
$1,250
Mar 25, 2021Construction CLASS - 1
FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURE OR TEMP CONST-NO GUARDRAILS.NOTE:@TIME OF MY INSP OF 3STYNB@2FL LEVEL UNDER CONST.I OBSERVEDWORKERS WORKING@2FL LEVEL SOME LOCATIONS NO GUARDRAILS SOME LOC
#35551374N
Jun 15, 2021
IN VIOLATION
$67
Mar 25, 2021Construction CLASS - 1
FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SEC REQUIREMENTS.NOTE:@TIME OF MY INSP OF 3STYNB@2FL LEVEL UNDER CONST,I OBSERVED ACTIVE JOBSITE.INADEQUATE HOUSEKEEPING FOUND ALL AROUND JOBSITE NOT MAINTAIN AS RE
#35551373L
Jun 15, 2021
IN VIOLATION
$2,500
Mar 25, 2021Construction CLASS - 2
FAILURE TO SAFEGUARD ALL PERSONS&PROPERTY AFFECTED BY CONST.NOTE:@TIMEOF MY INSP OF 3STYNB@2FL LEVEL UNDER CONST.I OBSERVED ACTIVE JOBSITE ADJ PROPERTY@EXP2@19-40FLUSHINGAVE EXTERIOR WALL CRACKS FOUND VERTICALL
#35551372J
Jun 15, 2021
IN VIOLATION
$5,000
Mar 25, 2021Site Safety CLASS - 1
CONST SUPER FAILED TO PERFORM DUTIES PERCODE.NOTE:@TIME OF MY INSP OF 3STYNB@2FL LEVEL UNDER CONST:I OBSERVED ACTIVE JOBSITE.COMPETENT PERSON PRESENT@JOBSITE JOBSITE VERY UNSAFE CONDITIONS NOT COMPLY W/SITE SAF
#35551378K
Jun 15, 2021
IN VIOLATION
$10,000
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)