Manhattan · Block 1628 · Lot 29 · 10029

189 East 100 Street

5 floors · 17 apartments · 9,205 sq ft · built 1910 · class C4 · owner of record: Nyc Department Of Homeless Services

36open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 44 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 44 days
Annual
Annual boiler inspection (3 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-11-14 (Accepted). Agency page

Dec 31, 2026
in 44 days
3 of 3 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 60 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueNo current registration found
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 409 days
Next cycle year 2027

Open violations

ECB / OATH (35)
IssuedViolationHearingBalance
Oct 8, 2025Boilers CLASS - 2
WEIL MCLAIN BOILER MODEL- EG65. CEILING INSULATION IS HANGING ON TOP OF BOILER. REPLACE INSULATION.
#39162991P
Oct 20, 2025
POP/IN-VIO
$0
Oct 8, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE. OBSERVED HOLE PENATRATIONS. LOCATED AT BASEMENT LEVEL. HOLE ABOVE COMPACTOR TUNNE
#39163091Y
Oct 20, 2025
POP/IN-VIO
$0
Nov 14, 2024Unknown CLASS - 2
I OBSERVED IN THE FIRST FLOOR MAINTENANCE ROOM NO GFCI PROTECTION WITHIN 6 FEET OF A SINK., INSTALL GFC1 PROTECTION; PROVIDE GFCI PROTECTION.
#39130284J
Nov 21, 2024
POP/IN-VIO
$0
Nov 14, 2024Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE. OBSERVED HOLE PENETRAIONS IN HALLWAY AT ROOF LEVEL AND THROUGHOUT BASEMENT. POTEN
#39130303X
Nov 21, 2024
POP/IN-VIO
$0
Nov 14, 2024Construction CLASS - 2
EXIT DOOR NOT SELF-CLOSING. OBSERVED NON SELF CLOSING DOORS AT BASEMENT LEVEL AND ROOF LEVEL. POTENTIAL FIRE OR SMOKE HAZARD., REPAIR/REPLACE DOOR
#39130304H
Nov 21, 2024
POP/IN-VIO
$0
Dec 21, 2023Construction CLASS - 1
UNLAW ACTS: FAILURE TO COMPLY WITH COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION# 39076993H ISSUED ON 01/04/2023 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01., COMPLY WITH
#39102044M
Jan 2, 2024
POP/IN-VIO
$0
Apr 5, 2023Unknown CLASS - 2
I OBSERVED IN THE MAINTENANCE CLOSET THE RECEPTACLE WITHIN 6 FEET OF THE SINK NOT OF THE GFCI TYPE., INSTALL GFC1 PROTECTION
#39083145K
Apr 27, 2023
POP/IN-VIO
$0
Jan 4, 2023Construction CLASS - 2
OBSERVED EXCESSIVE COMBUSTIBLE STORAGE IN THE BOILER LOCATED IN THE BASEMENT, NO STORAGE SHALL BE STORED IN THE BOILER ROOM., REPAIR AND/OR REPLACE
#39076950H
Jan 10, 2023
POP/IN-VIO
$0
Jan 4, 2023Construction CLASS - 2
OBSERVED: AT CELLAR LEVEL, FRONT EXIT DOOR AND FIRST FLOOR MAIN ENTRANCE DOOR DO NOT CLOSE PROPERLY WHEN INSPECTED., REPAIR/REPLACE DOOR
#39076994J
Jan 10, 2023
POP/IN-VIO
$0
Jan 4, 2023Construction CLASS - 2
OBSERVED: AT CELLAR LEVEL, BOILER ROOM, CEILING DOES NOT MEET TECHNICAL SPECIFICATIONS AND FIRE DEPARTMENT REQUIREMENTS.(INSULATION EXPOSED WITHOUT FIRE PROTECTION), REPAIR AND/OR REPLACE
#39076995L
Jan 10, 2023
POP/IN-VIO
$0
Jan 4, 2023Construction CLASS - 2
OBSERVED GAS PIPING IN BASEMENT HAS AREAS OF RUST AND CORROSION., REPAIR AND/OR REPLACE
#39076951J
Jan 10, 2023
POP/IN-VIO
$0
Jan 4, 2023Construction CLASS - 1
OBSERVED: AT CELLAR LEVEL, EXIT PASSAGEWAY FROM BOILER ROOM TO THE FRONT IS BEING OBSTRUCTED BY FLAMMABLE MATERIALS, SUCH AS WOOD DOORS, CARTON BOARD BOXES, EQUIPMENT AND OTHER MATERIALS. ALSO, SEVERAL WINDOWS
#39076993H
Jan 10, 2023
POP/IN-VIO
$0
Jan 4, 2023Construction CLASS - 2
OBSERVED: AT ROOF LEVEL, STAIRCASE EXTERIOR WALLS CRACKED NEAR EXIT DOOR, MAINTAIN EXTERIOR BUILDING WALL
#39076992X
Jan 10, 2023
POP/IN-VIO
$0
Nov 5, 2021Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.LACK OF EMERGENCY LIGHTING FOR EXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-542.OBSERVED 6 STORY BUILDING WITH FRONT AND BACK EXITS W/O EMERG
#35631755R
Feb 17, 2022
POP/IN-VIO
$0
Sep 15, 2021Boilers CLASS - 2
INSULATION ON THE BOILER ROOM CEILING IS LOOSE AND FALLING/FRESH AIR LOUVER IS 1/2 CLOGGED;CORRECT VIOLATION AND SUBMIT THE CERTIFICATE OF CORRECTION
#39047515K
Oct 15, 2021
POP/IN-VIO
$0
Mar 22, 2019Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES NOTED: OBSERVED HORIZONTAL CRACKS AND BULGIN CEMET ALONG THE LENGTH OF THE RETAINING WALL AT FRONT OF BUILDINGS SOUTH ELEVATION (EXP1).RMDY: MAINTAIN EXTER
#35383817N
May 30, 2019
POP/IN-VIO
$0
Sep 28, 2018Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTED:AT BULKHEAD EXTERIOR, ABOVE BULKHEAD EXIT DOOR, BRICKS ARE LOOSE AND MORTAR MISSING. ALSO AT FRONT AREAWAY BELOW BUILDING ENTRANCE STAIRS, RETAINING
#35361393L
Nov 29, 2018
POP/IN-VIO
$0
Sep 14, 2018Unknown CLASS - 1
EC250.53 WATER METER JUMPER IS MISSING. OBSERVED THE FOLLOWING VIOLATING CONDITION IN THE CELLAR. WATER METER JUMPER (MAIN GROUNDING JUMPER) MISSING; NOT INSTALLED. REM: COMPLY WITH EC CODE.
#35347398J
Dec 6, 2018
POP/IN-VIO
$0
Jun 27, 2018Boilers CLASS - 2
50A-F. AS PER CLASS 2(B254)28-301.1. FAILURE TO MAINTAIN. (50A)SAFETY VALVE FOR HEATING BOILER LEAKING.(50B)HOT WATER PIPING NOT CAPPED.(50C)NO PROVING SWITCH INSTALLED ON MOTORIZED FRESH AIR DAMPERS.(50D)DRAIN
#32097250P
Oct 11, 2018
POP/IN-VIO
$0
Apr 20, 2018Boilers CLASS - 2
5 - FOUND HYDROTHERM BOILER MODEL MR500BP 500,000 BTUS WITH DEFECTS TOBACKFLOW. CORRECT ANY OTHER VIOLATIONS AND SUBMIT A CERTIFICATE OF CORRECTION.
#32096413X
Jul 5, 2018
POP/IN-VIO
$0
Mar 23, 2018Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER:(INTERIOR)NOTED:OBSERVED AT ROOF AND STAIR BULKHEAD-SPALLING AND BULGING PLASTER AROUND THE SKYLIGHT DUE TO WATER PENETRATION.REM:REPAIR AND/OR REPLACE.
#35325702H
May 31, 2018
POP/IN-VIO
$0
Mar 23, 2018Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NO FIRE STOPPINGPER BC712.3;27-345.NOTED:OBSERVED AT CELLAR WITHIN BOILER-ROOM-THERE IS AN APPROX 12 INCH X 16 INCH HOLE IN THE CONCRETE CEILING NEAR EXPANS
#35325700Y
May 31, 2018
POP/IN-VIO
$0
Mar 23, 2018Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:OBSERVED AT REAR OF BUILDING FIRE ESCAPE DROP LADDER HAS COME OFF OF THE TWO(2)SIDE SLIDING RAILS/GUIDE AND IS ONLY BEING SUSPENDED BY THE IRON HOOK.R
#35325701X
May 31, 2018
POP/IN-VIO
$0
Mar 23, 2018Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING WALL(S)OR APPURTENANCES.NOTED:OBSERVED ATFRONT OF BUILDING THE RETAINING WALL HAS CRAKCS ALONG THE ENTIRE LENGTH OF WALL,SPALLING AND BULGING CONCRETE NEXT TO STAIRS TO CELLAR AND G
#35322499H
May 31, 2018
POP/IN-VIO
$0
Aug 22, 2017Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTED: OBSERVED AT FRONT OF BUILDING, RETAINING WALL HAS A CRACK ACROSS THE LENGTH OF THE ENTIRE WALL. REM: MAINTAIN EXTERIOR BUILDING WALL.
#35290003L
Dec 21, 2017
POP/IN-VIO
$0
Aug 22, 2017Plumbing CLASS - 1
FGC 411.1 RESIDENTAIL GAS FLEX USED ON COMMERCIAL EQUIPMENT.OBSERVED ON 08/22/2017 @ABOVE ADDRESS RESIDENTAIL GAS FLEX USED ON COMMERCIAL LAUNDRY EQUIPMENT.COMPLY W/SUMMONS.
#35289646R
Dec 21, 2017
POP/IN-VIO
$0
Aug 22, 2017Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: OBSERVED AT ROOF BULKHEAD, CEILING AROUND SKYLIGHT HAS SPALLING PLASTER DUE TO WATER PENETRATION. REM: REPAIR AND/OR REPLACE.
#35290004N
Dec 21, 2017
POP/IN-VIO
$0
Aug 22, 2017Construction CLASS - 2
FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED IN BSMT ANUNSERVICEABLE ELECTRICALLY POWERED GARBAGE COMPACTOR.MECHANICAL PARTS & ELECTRICAL COMPONENTS ARE EXTREMELY CORRODED DUE TO LACK OF MAINTENA
#35290278K
Oct 19, 2017
POP/IN-VIO
$0
Mar 27, 2017Plumbing CLASS - 1
SEC. 401.1 GAS PIPING NOT LABELED OBSERVED ON 3-27-17 IN BASEMENT/CELLAR GAS PIPING NOT LABELED. REMEDY: COMPLY W/SUMMONS.
#35235746K
Apr 27, 2017
POP/IN-VIO
$0
Mar 27, 2017Plumbing CLASS - 1
SEC. 408.2 DRIPS FUTURE CONNECTION EXIST DOWN STREM OF APPLICANCE. OBSERVED ON 3-27-17 IN BASEMENT/CELLAR FUTURE GAS CONNECTION IN COMPACTOR ROOM. REMEDY: COMPLY W/SUMMONS.
#35235739M
Apr 27, 2017
POP/IN-VIO
$0
Mar 27, 2017Plumbing CLASS - 2
FAIL TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED ON 3-27-17 JIM CAPS INSTALLED IN BOILER AREA. REMEDY: REMOVE ALL NON COMPLYING MATERIAL OR EQUIPMENT.
#35235745Z
Apr 27, 2017
POP/IN-VIO
$0
Sep 16, 2016Plumbing CLASS - 2
FAILURE TO HAVE NEW OR ALTERED PLY SYSTEM TESTED. OBSERVED ON 9/16/16 AT 10:15AM IN BST NEW HOT WATER STORAGE TANK AND ALL ASSOC WATER PIPING. NO DOB INSPECTIONS ON FILE FOR WORK. PHOTO TAKEN.RMDY:PERFORM INSPE
#35208031N
Nov 17, 2016
POP/IN-VIO
$0
Sep 16, 2016Construction CLASS - 2
EXIT DOOR NOT SELF-CLOSING THE FOLLOWING DOORS NOT SELF-CLOSING.EXIT DOOR TO ROOF LEVEL, ELECTIRC/GAS METER ROOM DOOR AT CELLAR LEVEL.RMDY:REPAIR/REPLACE DOORS.
#35207829H
Nov 17, 2016
POP/IN-VIO
$0
Sep 16, 2016Construction CLASS - 2
FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.DEFECT NOTE:APPROXIMAELY 9SF AREA CEILING MISSING AT 1ST FLR LOBBY. RMDY:REPAIR AND/OR REPLACE CEILING.
#35207830P
Nov 17, 2016
POP/IN-VIO
$0
Sep 16, 2016Construction CLASS - 2
FAILURE TO MAINTAIN IN CODE COMPLIANT MANNER. DEFECTS NOTED:RETAINING WALL AT FRONT OF PREMISES HAS APPRX 2"WIDE HORIZONTAL CRACK ALONG THE LENGTH OF THE WALL.RMDY:COMPLY WITH NOTICE OF VIOLATION.
#35207841K
Nov 17, 2016
POP/IN-VIO
$0
DOB (0)

None open.

DOB NOW Safety (1)
IssuedViolationStatus
Jan 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle D (premises is in Community District 11)
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 17, 2026, 7:43 PM ET. BBL 1016280029.

Look up another building