5 floors · 17 apartments · 9,205 sq ft · built 1910 · class C4 · owner of record: Nyc Department Of Homeless Services
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 44 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 44 days | Annual |
| Annual boiler inspection (3 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-11-14 (Accepted). Agency page | Dec 31, 2026 in 44 days | 3 of 3 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 60 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 409 days | Next cycle year 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 8, 2025 | Boilers CLASS - 2 WEIL MCLAIN BOILER MODEL- EG65. CEILING INSULATION IS HANGING ON TOP OF BOILER. REPLACE INSULATION. #39162991P | Oct 20, 2025 POP/IN-VIO | $0 |
| Oct 8, 2025 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE. OBSERVED HOLE PENATRATIONS. LOCATED AT BASEMENT LEVEL. HOLE ABOVE COMPACTOR TUNNE #39163091Y | Oct 20, 2025 POP/IN-VIO | $0 |
| Nov 14, 2024 | Unknown CLASS - 2 I OBSERVED IN THE FIRST FLOOR MAINTENANCE ROOM NO GFCI PROTECTION WITHIN 6 FEET OF A SINK., INSTALL GFC1 PROTECTION; PROVIDE GFCI PROTECTION. #39130284J | Nov 21, 2024 POP/IN-VIO | $0 |
| Nov 14, 2024 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE. OBSERVED HOLE PENETRAIONS IN HALLWAY AT ROOF LEVEL AND THROUGHOUT BASEMENT. POTEN #39130303X | Nov 21, 2024 POP/IN-VIO | $0 |
| Nov 14, 2024 | Construction CLASS - 2 EXIT DOOR NOT SELF-CLOSING. OBSERVED NON SELF CLOSING DOORS AT BASEMENT LEVEL AND ROOF LEVEL. POTENTIAL FIRE OR SMOKE HAZARD., REPAIR/REPLACE DOOR #39130304H | Nov 21, 2024 POP/IN-VIO | $0 |
| Dec 21, 2023 | Construction CLASS - 1 UNLAW ACTS: FAILURE TO COMPLY WITH COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION# 39076993H ISSUED ON 01/04/2023 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01., COMPLY WITH #39102044M | Jan 2, 2024 POP/IN-VIO | $0 |
| Apr 5, 2023 | Unknown CLASS - 2 I OBSERVED IN THE MAINTENANCE CLOSET THE RECEPTACLE WITHIN 6 FEET OF THE SINK NOT OF THE GFCI TYPE., INSTALL GFC1 PROTECTION #39083145K | Apr 27, 2023 POP/IN-VIO | $0 |
| Jan 4, 2023 | Construction CLASS - 2 OBSERVED EXCESSIVE COMBUSTIBLE STORAGE IN THE BOILER LOCATED IN THE BASEMENT, NO STORAGE SHALL BE STORED IN THE BOILER ROOM., REPAIR AND/OR REPLACE #39076950H | Jan 10, 2023 POP/IN-VIO | $0 |
| Jan 4, 2023 | Construction CLASS - 2 OBSERVED: AT CELLAR LEVEL, FRONT EXIT DOOR AND FIRST FLOOR MAIN ENTRANCE DOOR DO NOT CLOSE PROPERLY WHEN INSPECTED., REPAIR/REPLACE DOOR #39076994J | Jan 10, 2023 POP/IN-VIO | $0 |
| Jan 4, 2023 | Construction CLASS - 2 OBSERVED: AT CELLAR LEVEL, BOILER ROOM, CEILING DOES NOT MEET TECHNICAL SPECIFICATIONS AND FIRE DEPARTMENT REQUIREMENTS.(INSULATION EXPOSED WITHOUT FIRE PROTECTION), REPAIR AND/OR REPLACE #39076995L | Jan 10, 2023 POP/IN-VIO | $0 |
| Jan 4, 2023 | Construction CLASS - 2 OBSERVED GAS PIPING IN BASEMENT HAS AREAS OF RUST AND CORROSION., REPAIR AND/OR REPLACE #39076951J | Jan 10, 2023 POP/IN-VIO | $0 |
| Jan 4, 2023 | Construction CLASS - 1 OBSERVED: AT CELLAR LEVEL, EXIT PASSAGEWAY FROM BOILER ROOM TO THE FRONT IS BEING OBSTRUCTED BY FLAMMABLE MATERIALS, SUCH AS WOOD DOORS, CARTON BOARD BOXES, EQUIPMENT AND OTHER MATERIALS. ALSO, SEVERAL WINDOWS #39076993H | Jan 10, 2023 POP/IN-VIO | $0 |
| Jan 4, 2023 | Construction CLASS - 2 OBSERVED: AT ROOF LEVEL, STAIRCASE EXTERIOR WALLS CRACKED NEAR EXIT DOOR, MAINTAIN EXTERIOR BUILDING WALL #39076992X | Jan 10, 2023 POP/IN-VIO | $0 |
| Nov 5, 2021 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.LACK OF EMERGENCY LIGHTING FOR EXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-542.OBSERVED 6 STORY BUILDING WITH FRONT AND BACK EXITS W/O EMERG #35631755R | Feb 17, 2022 POP/IN-VIO | $0 |
| Sep 15, 2021 | Boilers CLASS - 2 INSULATION ON THE BOILER ROOM CEILING IS LOOSE AND FALLING/FRESH AIR LOUVER IS 1/2 CLOGGED;CORRECT VIOLATION AND SUBMIT THE CERTIFICATE OF CORRECTION #39047515K | Oct 15, 2021 POP/IN-VIO | $0 |
| Mar 22, 2019 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES NOTED: OBSERVED HORIZONTAL CRACKS AND BULGIN CEMET ALONG THE LENGTH OF THE RETAINING WALL AT FRONT OF BUILDINGS SOUTH ELEVATION (EXP1).RMDY: MAINTAIN EXTER #35383817N | May 30, 2019 POP/IN-VIO | $0 |
| Sep 28, 2018 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTED:AT BULKHEAD EXTERIOR, ABOVE BULKHEAD EXIT DOOR, BRICKS ARE LOOSE AND MORTAR MISSING. ALSO AT FRONT AREAWAY BELOW BUILDING ENTRANCE STAIRS, RETAINING #35361393L | Nov 29, 2018 POP/IN-VIO | $0 |
| Sep 14, 2018 | Unknown CLASS - 1 EC250.53 WATER METER JUMPER IS MISSING. OBSERVED THE FOLLOWING VIOLATING CONDITION IN THE CELLAR. WATER METER JUMPER (MAIN GROUNDING JUMPER) MISSING; NOT INSTALLED. REM: COMPLY WITH EC CODE. #35347398J | Dec 6, 2018 POP/IN-VIO | $0 |
| Jun 27, 2018 | Boilers CLASS - 2 50A-F. AS PER CLASS 2(B254)28-301.1. FAILURE TO MAINTAIN. (50A)SAFETY VALVE FOR HEATING BOILER LEAKING.(50B)HOT WATER PIPING NOT CAPPED.(50C)NO PROVING SWITCH INSTALLED ON MOTORIZED FRESH AIR DAMPERS.(50D)DRAIN #32097250P | Oct 11, 2018 POP/IN-VIO | $0 |
| Apr 20, 2018 | Boilers CLASS - 2 5 - FOUND HYDROTHERM BOILER MODEL MR500BP 500,000 BTUS WITH DEFECTS TOBACKFLOW. CORRECT ANY OTHER VIOLATIONS AND SUBMIT A CERTIFICATE OF CORRECTION. #32096413X | Jul 5, 2018 POP/IN-VIO | $0 |
| Mar 23, 2018 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER:(INTERIOR)NOTED:OBSERVED AT ROOF AND STAIR BULKHEAD-SPALLING AND BULGING PLASTER AROUND THE SKYLIGHT DUE TO WATER PENETRATION.REM:REPAIR AND/OR REPLACE. #35325702H | May 31, 2018 POP/IN-VIO | $0 |
| Mar 23, 2018 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NO FIRE STOPPINGPER BC712.3;27-345.NOTED:OBSERVED AT CELLAR WITHIN BOILER-ROOM-THERE IS AN APPROX 12 INCH X 16 INCH HOLE IN THE CONCRETE CEILING NEAR EXPANS #35325700Y | May 31, 2018 POP/IN-VIO | $0 |
| Mar 23, 2018 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:OBSERVED AT REAR OF BUILDING FIRE ESCAPE DROP LADDER HAS COME OFF OF THE TWO(2)SIDE SLIDING RAILS/GUIDE AND IS ONLY BEING SUSPENDED BY THE IRON HOOK.R #35325701X | May 31, 2018 POP/IN-VIO | $0 |
| Mar 23, 2018 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING WALL(S)OR APPURTENANCES.NOTED:OBSERVED ATFRONT OF BUILDING THE RETAINING WALL HAS CRAKCS ALONG THE ENTIRE LENGTH OF WALL,SPALLING AND BULGING CONCRETE NEXT TO STAIRS TO CELLAR AND G #35322499H | May 31, 2018 POP/IN-VIO | $0 |
| Aug 22, 2017 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTED: OBSERVED AT FRONT OF BUILDING, RETAINING WALL HAS A CRACK ACROSS THE LENGTH OF THE ENTIRE WALL. REM: MAINTAIN EXTERIOR BUILDING WALL. #35290003L | Dec 21, 2017 POP/IN-VIO | $0 |
| Aug 22, 2017 | Plumbing CLASS - 1 FGC 411.1 RESIDENTAIL GAS FLEX USED ON COMMERCIAL EQUIPMENT.OBSERVED ON 08/22/2017 @ABOVE ADDRESS RESIDENTAIL GAS FLEX USED ON COMMERCIAL LAUNDRY EQUIPMENT.COMPLY W/SUMMONS. #35289646R | Dec 21, 2017 POP/IN-VIO | $0 |
| Aug 22, 2017 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: OBSERVED AT ROOF BULKHEAD, CEILING AROUND SKYLIGHT HAS SPALLING PLASTER DUE TO WATER PENETRATION. REM: REPAIR AND/OR REPLACE. #35290004N | Dec 21, 2017 POP/IN-VIO | $0 |
| Aug 22, 2017 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED IN BSMT ANUNSERVICEABLE ELECTRICALLY POWERED GARBAGE COMPACTOR.MECHANICAL PARTS & ELECTRICAL COMPONENTS ARE EXTREMELY CORRODED DUE TO LACK OF MAINTENA #35290278K | Oct 19, 2017 POP/IN-VIO | $0 |
| Mar 27, 2017 | Plumbing CLASS - 1 SEC. 401.1 GAS PIPING NOT LABELED OBSERVED ON 3-27-17 IN BASEMENT/CELLAR GAS PIPING NOT LABELED. REMEDY: COMPLY W/SUMMONS. #35235746K | Apr 27, 2017 POP/IN-VIO | $0 |
| Mar 27, 2017 | Plumbing CLASS - 1 SEC. 408.2 DRIPS FUTURE CONNECTION EXIST DOWN STREM OF APPLICANCE. OBSERVED ON 3-27-17 IN BASEMENT/CELLAR FUTURE GAS CONNECTION IN COMPACTOR ROOM. REMEDY: COMPLY W/SUMMONS. #35235739M | Apr 27, 2017 POP/IN-VIO | $0 |
| Mar 27, 2017 | Plumbing CLASS - 2 FAIL TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED ON 3-27-17 JIM CAPS INSTALLED IN BOILER AREA. REMEDY: REMOVE ALL NON COMPLYING MATERIAL OR EQUIPMENT. #35235745Z | Apr 27, 2017 POP/IN-VIO | $0 |
| Sep 16, 2016 | Plumbing CLASS - 2 FAILURE TO HAVE NEW OR ALTERED PLY SYSTEM TESTED. OBSERVED ON 9/16/16 AT 10:15AM IN BST NEW HOT WATER STORAGE TANK AND ALL ASSOC WATER PIPING. NO DOB INSPECTIONS ON FILE FOR WORK. PHOTO TAKEN.RMDY:PERFORM INSPE #35208031N | Nov 17, 2016 POP/IN-VIO | $0 |
| Sep 16, 2016 | Construction CLASS - 2 EXIT DOOR NOT SELF-CLOSING THE FOLLOWING DOORS NOT SELF-CLOSING.EXIT DOOR TO ROOF LEVEL, ELECTIRC/GAS METER ROOM DOOR AT CELLAR LEVEL.RMDY:REPAIR/REPLACE DOORS. #35207829H | Nov 17, 2016 POP/IN-VIO | $0 |
| Sep 16, 2016 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.DEFECT NOTE:APPROXIMAELY 9SF AREA CEILING MISSING AT 1ST FLR LOBBY. RMDY:REPAIR AND/OR REPLACE CEILING. #35207830P | Nov 17, 2016 POP/IN-VIO | $0 |
| Sep 16, 2016 | Construction CLASS - 2 FAILURE TO MAINTAIN IN CODE COMPLIANT MANNER. DEFECTS NOTED:RETAINING WALL AT FRONT OF PREMISES HAS APPRX 2"WIDE HORIZONTAL CRACK ALONG THE LENGTH OF THE WALL.RMDY:COMPLY WITH NOTICE OF VIOLATION. #35207841K | Nov 17, 2016 POP/IN-VIO | $0 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Jan 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle D (premises is in Community District 11) | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 17, 2026, 7:43 PM ET. BBL 1016280029.