3 floors · 516 apartments · 483,292 sq ft · built 1949 · class C9 · owner of record: Queens Fresh Meadows, Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 51 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 51 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 51 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 67 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 483,292 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 172 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 172 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 295 days | Registered through 2027-09-01 |
| Energy audit and retro-commissioning (2027) Likely applies Local Law 87 · Calendar year 2027 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 7117). Agency page | Dec 31, 2027 in 416 days | Next due 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 31, 2026 | Unknown CLASS - 1 FAILURE TO MAINTAIN PARKING STRUCTURES IN A SAFE CONDITION. AT TIME OFINSPECTION ON AN OCCUPIED PARKING STRUCTURE CONSISTING OF 2 LEVELS BELOW GRADE AND 4 LEVELS ABOVE GRADE AT ROOF, OBSERVED SPALLED/CRACKED CO #35730091R | Dec 1, 2026 PENDING | $12,500 |
| Jul 30, 2026 | Construction CLASS - 1 OBSERVED AT GARAGE LEVEL B CEMENT FOR CEILING RE BAR HAS DISLODGED AND FALLEN IN FRONT OF PARKING SPACE 60 AND 57, ALSO AT LEVEL A CEMENT FOR CEILING RE BAR IS LOOSE WITH THE POTENTIAL OF FALLING IN FRONT OF PA #39198557R | Oct 6, 2026 DEFAULT | $2,530 |
| Issued | Violation | Status |
|---|---|---|
| Aug 4, 2026 | CONSTRUCTION PARTIAL VACATE ORDER: VACATE 66'WX56'D OF CELLAR N. WING 66'W X'61'D OF CELLARS WING AND 1 FL LEVELS. NOTE:DETERIORATED CONCRETE SLABS WERE ODSERVED WITHIN THE PARKING GARAGE,AT MULTIPLE LOCATIONS. NO SAFETY P ROTECTION IN PLACE THROUGHOUT THE PARKING GARAGE PRESEMTING IMMEDIATE HAZARD TO THE PUBLIC #PS40801AK | DOB VIOLATION - ACTIVE |
| Aug 4, 2026 | CONSTRUCTION PVO. VACATE 66'X56' OF CELLAR N.WING.DETERIORATED CONCRETE SLABS OBSER IN PARKING GARAGE INCLUDING SPALLING CONCRETE & EXPOSED CORRODED REBAR & LOOSE MATERIAL @ MULT LOCS. NO SAFETY PROTECTION THROUGHOUT PARKING GARAGE. REMEDY:RENDER PARKING GARAGE SUB-CELLAR & ENTIRE CELLAR LVL B UNSAFE TO OCCUPY.S #PS10801AK | DOB VIOLATION - ACTIVE |
| Aug 4, 2026 | CONSTRUCTION PARTIAL VACATE ORDER VACATE 66'W X 56' OF CELLAR N.WING 66'WX61' OF CELLAR S. WING AND 1 FL LEVEL. DETERIORATED CONCRETE SLABS WERE OBSERV ED WITH THE PARKING GARAGE, INCLUDING SPALLING CONCRETE AND EXPOSED CO RRODED REBAR AND LOSSE MATERIALS AT MULITPLE LOCATION. NO SATFET PROTE CTION IN PLACE THRO #PS40801MK | DOB VIOLATION - ACTIVE |
| Jul 31, 2026 | CONSTRUCTION EWO. DUE TO SEVERELY DETERIORATED PARAPET WALL @ N.ELEV ALONG 69 AVE THE UNSTABLE MASONRY POSES AN IMMEDIATE HAZRD TO PUBLIC SAFETY. REMDY: IMMEDIATELY IMPLEMENT ADEQTE OVERHEAD PROTECTION, SIDEWALK SHEDDING, ETC. TO SECURE THE AREA & PROTECT THE PUBLIC. PROCEED WITH EMERGNCY STABILZTN & PERMANANT R #PS0801AK | DOB VIOLATION - ACTIVE |
| Jul 31, 2026 | CONSTRUCTION APPRX 3FT OF RAMP@UNDERSIDE OF 1STFL APPRX 68FTX61FT HAD VARIOUS AREAS OF SPALLNG W/REBAR EXPSD&CORRODED.WATER DMG@UNDERSIDE OF 1SFTFL@NORTH WNG.PARAPET&EXP 1,2,3,&4 HAD VARIOUS CRCKS/DEFCT.OWNR TO IMMED RTAIN QPSI&GC REG TO IMMED 1.INSTLL PHYSICAL BARRIERS TO PRVTN ACCESS TO THE PRTLLY VACATED AREA #FEU40801BP | DOB VIOLATION - ACTIVE |
| Jul 30, 2026 | CONSTRUCTION OBSERVED AT GARAGE LEVEL B CEMENT FOR CEILING RE BAR HAS DISLODGED AND FALLEN IN FRONT OF PARKING SPACE 60 AND 57, ALSO AT LEVEL A CEMENT FOR CEILING RE BAR IS LOOSE WITH THE POTENTIAL OF FALLING IN FRONT OF PARKING SPACES 40 AND 42. #26-01899 | DOB VIOLATION - ACTIVE |
| Jun 7, 1994 | LOCAL LAW 62/91 - BOILERS #08012 | DOB VIOLATION - ACTIVE |
| Jun 7, 1994 | LOCAL LAW 62/91 - BOILERS #08010 | DOB VIOLATION - ACTIVE |
| Jun 28, 1993 | LOCAL LAW 62/91 - BOILERS #17166 | DOB VIOLATION - ACTIVE |
| Jun 28, 1993 | LOCAL LAW 62/91 - BOILERS #17168 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Jun 7, 1994 | Boiler LL6291 | Active |
| Jun 7, 1994 | Boiler LL6291 | Active |
| Jun 7, 1994 | Boiler LL6291 | Active |
| Jun 28, 1993 | Boiler LL6291 | Active |
| Jun 28, 1993 | Boiler LL6291 | Active |
| Jun 28, 1993 | Boiler LL6291 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Oct 29, 2026 | A | Apt 1A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ FT OBSERVED AT WINDOW RECESS AT WEST WALL IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Feb 1, 2027 |
| Oct 29, 2026 | C | Apt 1A · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SCALDING HOT WATER ABOVE 130 DEGREES IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 4, 2026 |
| Oct 21, 2026 | A | Apt 1A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ FEET AT CEILING IN THE BATHROOM LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 24, 2027 |
| Oct 19, 2026 | A | Apt F · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WATER CLOSET IN THE BATHROOM LOCATED AT APT F, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Jan 22, 2027 |
| Oct 19, 2026 | B | Apt F · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT F, 1st STORY, 1st BSMT-APT FROM EAST AT SOUTH | Nov 23, 2026 |
| Oct 19, 2026 | B | Apt F · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT F, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Nov 23, 2026 |
| Oct 19, 2026 | C | Apt F · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT F, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Nov 14, 2026 |
| Oct 19, 2026 | C | Apt F · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MORE THAN 30 SQ FT AT CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT F, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Nov 14, 2026 |
| Oct 19, 2026 | B | Apt F · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT F, 1st STORY, 1st BSMT-APT FROM EAST AT SOUTH | Nov 23, 2026 |
| Oct 19, 2026 | B | Apt F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT F, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Nov 23, 2026 |
| Aug 20, 2026 | B | Apt 1B · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT EAST WALL IN THE BATHROOM LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Sep 24, 2026 |
| Aug 20, 2026 | B | Apt 1B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING, NORTH AND WEST WALLS IN THE BATHROOM LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Sep 24, 2026 |
| Aug 20, 2026 | A | Apt 1B · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET OBSERVED AT CEILING AND WEST WALL IN THE BATHROOM LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 23, 2026 |
| Jul 17, 2026 | B | Apt 1A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 21, 2026 |
| Jul 16, 2026 | B | Apt 1A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Aug 20, 2026 |
| Jun 17, 2026 | B | Apt B · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT B, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Jul 22, 2026 |
| Jun 15, 2026 | B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT DOOR LEADING TO HOPPER DOOR AT NORTH WALL AT PUBLIC HALL, 1st STORY | Jul 20, 2026 |
| May 18, 2026 | B | Apt 1A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 22, 2026 |
| May 18, 2026 | B | Apt 1A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT WEST WALL AND NORTH WALL IN THE FOYER LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 22, 2026 |
| May 18, 2026 | C | Apt 1A · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SCALDING HOT WATER ABOVE 130 DEGREES IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | May 24, 2026 |
| May 18, 2026 | B | Apt 1A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND SOUTH WALLS IN THE 4th ROOM FROM EAST AT NORTH LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 22, 2026 |
| May 18, 2026 | B | Apt 1A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST AND NORTH WALLS IN THE FOYER LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 22, 2026 |
| May 18, 2026 | B | Apt 1A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 22, 2026 |
| Aug 21, 2024 | C | Apt PH · § 27-2056.7, 27-2056.8, 27-2056.9 ADM CODE -CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY PERFORMING ACTIVITIES NECESSARY TO ABATE TESTED LEAD-BASED PAINT FROM REQUIRED WINDOW AND/OR DOOR FRICTION SURFACES FOR APARTMENT AND MAKE FLOORS SMOOTH A | Sep 28, 2024 |
| Jul 26, 2024 | B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AT DOOR TO HOPPER DOOR AT PUBLIC HALL, 3rd STORY | Aug 30, 2024 |
| May 28, 2024 | C | Apt J · § 27-2056.7, 27-2056.8, 27-2056.9 ADM CODE -CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY PERFORMING ACTIVITIES NECESSARY TO ABATE TESTED LEAD-BASED PAINT FROM REQUIRED WINDOW AND/OR DOOR FRICTION SURFACES FOR APARTMENT AND MAKE FLOORS SMOOTH A | Jun 21, 2024 |
| May 28, 2024 | C | Apt J · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FROM SOUTH AT WEST WALL, 1st DOOR FRAME FROM SOUTH AT WEST WALL, EAST WALL, W | Jul 5, 2024 |
| May 28, 2024 | C | Apt J · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FROM SOUTH AT WEST WALL, 1st DOOR FRAME FROM SOUTH AT WEST WALL, EAST WALL, W | Jul 5, 2024 |
| Jan 12, 2024 | B | Apt 16D · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 5 SQ, FT AT WEST WALL CLOSET FROM WEST AT NORTH WALL IN THE PRIVATE HALLWAY LOCATED AT APT 16D, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 16232562 ISSUED 13-SEP-23 HAS BEEN UPGRADED TO CL | Feb 16, 2024 |
| Dec 11, 2023 | C | Apt 1C · § 27-2056.7 ADM CODE: CORRECT FAILURE TO PROVIDE TO THE DEPARTMENT WITHIN 45 DAYS OF DEMAND ALL RECORDS REQUIRED TO BE MAINTAINED BY OWNER PURSUANT TO LOCAL LAW 1 OF 2004 RELATED TO LEAD-BASED PAINT NOTICES, INSPECTIONS AND REMEDIATION/ABATEMENT ACTIVITIES. | Dec 15, 2023 |
| Dec 11, 2023 | C | Apt 1C · § 27-2056.4 ADM CODE- CORRECT FAILURE TO NOTIFY OCCUPANTS AND/OR TO INVESTIGATE LEAD-BASED PAINT HAZARDS. | Dec 15, 2023 |
| Sep 14, 2023 | B | Apt 16D · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 20 SQ.FT AT CEILING, WEST WALL, EAST WALL IN THE BATHROOM LOCATED AT APT 16D, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 19, 2023 |
| Oct 4, 2021 | B | Apt H · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT H, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 8, 2021 |
| Oct 4, 2021 | A | Apt H · § 27-2013 ADMIN. CODE: PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 11th ROOM FROM EAST, THE KITCHEN LOCATED AT APT H, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Jan 7, 2022 |
| Oct 4, 2021 | B | Apt H · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT H, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 8, 2021 |
| Jun 25, 2021 | C | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCK AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY | Jul 1, 2021 |
| Jun 25, 2021 | A | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. | Sep 28, 2021 |
| Jun 24, 2021 | B | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE AT FRONT YARD OF THE BUILDING | Jul 29, 2021 |
| Jun 14, 2021 | C | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCK AND ASSEMBLY AT BUILING ENTRANCE DOOR, 69-11B 188 STREET AT PUBLIC HALL, 1st STORY | Jun 20, 2021 |
| Feb 28, 2020 | C | § 27-2056.4 ADM CODE- Correct failure to notify occupants and/or to investigate lead-based paint hazards. | Mar 5, 2020 |
| Feb 27, 2020 | C | Apt 1C · § 27-2056.8 ADM CODE -CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT ... IN THE ENTIRE APARTMENT LOCATED AT APT 1C, 1st STORY | Mar 4, 2020 |
| Feb 18, 2020 | C | Apt 2A · § 27-2056.7 ADM CODE: Correct failure to provide to the department within 45 days of demand all records required to be maintained by owner pursuant to Local Law 1 of 2004 related to lead-based paint notices, inspections and remediation/abatement activities. | Feb 24, 2020 |
| Nov 15, 2019 | A | Apt 2B · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING & ALL WALLS IN THE KITCHEN LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Feb 18, 2020 |
| Jan 14, 2019 | B | Apt 3A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE 3rd ROOM FROM EAST LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Feb 18, 2019 |
| Sep 13, 2018 | A | § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY | Dec 17, 2018 |
| Aug 17, 2017 | C | Apt 3A · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 10; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 2nd AP | Sep 14, 2017 |
| Jul 5, 2017 | A | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY | Oct 8, 2017 |
| Mar 21, 2016 | A | Apt 3A · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 3rd ROOM FROM EAST AT SOUTH, THE BATHROOM , THE 3rd ROOM FROM EAST AT NORTH, THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 3A, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SEC | Jun 24, 2016 |
| Dec 7, 2015 | A | Apt 1A · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 1st ROOM FROM NORTH AT EAST, THE 1st ROOM FROM NORTH AT WEST, THE BATHROOM , THE 2nd ROOM FROM NORTH, THE KITCHEN LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Mar 11, 2016 |
| Dec 7, 2015 | A | Apt 1A · § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 1st DOOR FROM EAST AT SOUTH WALL IN THE FOYER LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''50A'' | Mar 11, 2016 |
| May 5, 2015 | B | Apt B · § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT B, 1st STORY, APARTMENT AT SOUTH | Jun 9, 2015 |
| Aug 7, 2014 | B | Apt 2C · SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 2nd STORY, APARTMENT AT EAST | Sep 11, 2014 |
| Aug 7, 2014 | A | Apt 2C · SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING THRU-OUT IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 2nd STORY, APARTMENT AT EAST | Nov 10, 2014 |
| Aug 7, 2014 | A | Apt 2C · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GASKET AROUND REFRIGERTOR DOORS IN THE KITCHEN LOCATED AT APT 2C, 2nd STORY, APARTMENT AT EAST | Nov 10, 2014 |
| Jan 10, 2014 | A | Apt 3B · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 1st ROOM FROM NORTH, THE 4th ROOM FROM NORTH, THE BATHROOM , THE PRIVATE HALLWAY LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 14, 2014 |
| Nov 4, 2013 | B | Apt 1C · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR AT CENTR AND RADIATOR NORTH IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 1C, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Dec 9, 2013 |
| Sep 13, 2013 | B | Apt B · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK MIOSTURE PENETRATION AT NORTH WALL FROM 1ST TO 2ND STORY (DUPLEX APARTMENT) IN THE PRIVATE HALLWAY LOCATED AT APT B, 1st STORY | Oct 18, 2013 |
| Sep 13, 2013 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICK POINTING AT NORTH , WEST AND SOUTH EXTEROIER WALL , 2nd STORY | Oct 18, 2013 |
| Sep 13, 2013 | B | Apt B · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT B, 1st STORY | Oct 18, 2013 |
| Sep 9, 2013 | B | Apt 1B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WEST WALL AND CEILING IN THE KITCHEN LOCATED AT APT 1B, 1st STORY | Nov 13, 2013 |
Showing 60 of 70. Full list on the agency site.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 29, 2026 | HPD A | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ FT OBSERVED AT WINDOW RECESS AT WEST WALL IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Oct 29, 2026 | HPD C | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SCALDING HOT WATER ABOVE 130 DEGREES IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Oct 21, 2026 | HPD A | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ FEET AT CEILING IN THE BATHROOM LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Oct 19, 2026 | HPD A | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WATER CLOSET IN THE BATHROOM LOCATED AT APT F, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |
| Oct 19, 2026 | HPD B | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT F, 1st STORY, 1st BSMT-APT FROM EAST AT SOUTH | Open |
| Oct 19, 2026 | HPD B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT F, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |
| Oct 19, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT F, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |
| Oct 19, 2026 | HPD C | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MORE THAN 30 SQ FT AT CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT F, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |
| Oct 19, 2026 | HPD B | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT F, 1st STORY, 1st BSMT-APT FROM EAST AT SOUTH | Open |
| Oct 19, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT F, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |
| Sep 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Sep 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Aug 20, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT EAST WALL IN THE BATHROOM LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Open |
| Aug 20, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING, NORTH AND WEST WALLS IN THE BATHROOM LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Open |
| Aug 20, 2026 | HPD A | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET OBSERVED AT CEILING AND WEST WALL IN THE BATHROOM LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Open |
| Aug 4, 2026 | DOB | CONSTRUCTION: PARTIAL VACATE ORDER: VACATE 66'WX56'D OF CELLAR N. WING 66'W X'61'D OF CELLARS WING AND 1 FL LEVELS. NOTE:DETERIORATED CONCRETE SLABS WERE ODSERVED WITHIN THE PARKING GARAGE,AT MULTIPLE LOCATIONS. NO SAFETY P ROTECTION IN PLACE THROUGHOUT THE PARKING GARAGE PRESEMTING IMMEDIATE HAZARD TO THE PUBLIC | Open |
| Aug 4, 2026 | DOB | CONSTRUCTION: PVO. VACATE 66'X56' OF CELLAR N.WING.DETERIORATED CONCRETE SLABS OBSER IN PARKING GARAGE INCLUDING SPALLING CONCRETE & EXPOSED CORRODED REBAR & LOOSE MATERIAL @ MULT LOCS. NO SAFETY PROTECTION THROUGHOUT PARKING GARAGE. REMEDY:RENDER PARKING GARAGE SUB-CELLAR & ENTIRE CELLAR LVL B UNSAFE TO OCCUPY.S | Open |
| Aug 4, 2026 | DOB | CONSTRUCTION: PARTIAL VACATE ORDER VACATE 66'W X 56' OF CELLAR N.WING 66'WX61' OF CELLAR S. WING AND 1 FL LEVEL. DETERIORATED CONCRETE SLABS WERE OBSERV ED WITH THE PARKING GARAGE, INCLUDING SPALLING CONCRETE AND EXPOSED CO RRODED REBAR AND LOSSE MATERIALS AT MULITPLE LOCATION. NO SATFET PROTE CTION IN PLACE THRO | Open |
| Jul 31, 2026 | DOB | CONSTRUCTION: EWO. DUE TO SEVERELY DETERIORATED PARAPET WALL @ N.ELEV ALONG 69 AVE THE UNSTABLE MASONRY POSES AN IMMEDIATE HAZRD TO PUBLIC SAFETY. REMDY: IMMEDIATELY IMPLEMENT ADEQTE OVERHEAD PROTECTION, SIDEWALK SHEDDING, ETC. TO SECURE THE AREA & PROTECT THE PUBLIC. PROCEED WITH EMERGNCY STABILZTN & PERMANANT R | Open |
| Jul 31, 2026 | DOB | CONSTRUCTION: APPRX 3FT OF RAMP@UNDERSIDE OF 1STFL APPRX 68FTX61FT HAD VARIOUS AREAS OF SPALLNG W/REBAR EXPSD&CORRODED.WATER DMG@UNDERSIDE OF 1SFTFL@NORTH WNG.PARAPET&EXP 1,2,3,&4 HAD VARIOUS CRCKS/DEFCT.OWNR TO IMMED RTAIN QPSI&GC REG TO IMMED 1.INSTLL PHYSICAL BARRIERS TO PRVTN ACCESS TO THE PRTLLY VACATED AREA | Open |
| Jul 31, 2026 | ECB | Unknown: FAILURE TO MAINTAIN PARKING STRUCTURES IN A SAFE CONDITION. AT TIME OFINSPECTION ON AN OCCUPIED PARKING STRUCTURE CONSISTING OF 2 LEVELS BELOW GRADE AND 4 LEVELS ABOVE GRADE AT ROOF, OBSERVED SPALLED/CRACKED CO | Open |
| Jul 30, 2026 | DOB | CONSTRUCTION: OBSERVED AT GARAGE LEVEL B CEMENT FOR CEILING RE BAR HAS DISLODGED AND FALLEN IN FRONT OF PARKING SPACE 60 AND 57, ALSO AT LEVEL A CEMENT FOR CEILING RE BAR IS LOOSE WITH THE POTENTIAL OF FALLING IN FRONT OF PARKING SPACES 40 AND 42. | Open |
| Jul 30, 2026 | ECB | Construction: OBSERVED AT GARAGE LEVEL B CEMENT FOR CEILING RE BAR HAS DISLODGED AND FALLEN IN FRONT OF PARKING SPACE 60 AND 57, ALSO AT LEVEL A CEMENT FOR CEILING RE BAR IS LOOSE WITH THE POTENTIAL OF FALLING IN FRONT OF PA | Open |
| Jul 17, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Jul 16, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |