6 floors · 111,940 sq ft · built 2024 · class W2 · owner of record: Mdy Quentin Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 49 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 111,940 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 170 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 170 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 15 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 414 days | Next cycle year 2027 |
| Energy audit and retro-commissioning (2028) Likely applies Local Law 87 · Calendar year 2028 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 6658). Agency page | Dec 31, 2028 in 780 days | Next due 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jun 12, 2026 | Construction CLASS - 1 AT THE TIME OF MY INSPECTION OF A 6 STORY NEW BUILDING, I OBSERVED 1 WORKER OPERATING A FORKLIFT, UPON REQUEST FOR HIS CERTIFICATE TO OPERATE ACCORDING TO THE MANUFACTURE SPECIFICATION NONE WAS PRESENTED OR AT #39555404Z | Sep 23, 2026 IN VIOLATION | $2,500 |
| Jun 12, 2026 | Construction CLASS - 1 AT THE TIME OF MY INSPECTION OF A 6 STORY NEW BUILDING, I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURE #1 AND 2, UPON REVIEW OF THE SITE SAFETY PLAN IT REVEAL THAT SIDEWALK SHED AT EXPOSURE #1 SHOULD BE INSTALL #39555405K | May 3, 2027 PENDING | $2,500 |
| Jun 12, 2026 | Unknown CLASS - 1 AT THE TIME OF MY INSPECTION, I OBSERVED JERSEY BARRIERS WITH CHAIN LINK FENCE ON TOP COVERED WITH DEBRIS NETTING, UPON REVIEW OF THE DOT PERMIT IT ALLOWED TO ONLY OCCUPY 8 FEET OF ROADWAY AND THE BARRIERS WAS #39555403R | Sep 23, 2026 IN VIOLATION | $5,000 |
| May 28, 2026 | Unknown CLASS - 1 BC 3303.12.2.1 AT TIME OF INSPECTION OF A 6-STORY ACTIVE JOB SITE, BUILDING TOPPED OFF AT 99 FEET WITH NO ELEVATOR OR HOIST IN READINESS. CONDITION CREATES HAZARD TO PUBLIC/PROPERTY AND IMPEDES EMERGENCY ACCESS #39554745M | Mar 25, 2027 | $5,000 |
| May 28, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION OF A 6-STORY ACTIVE JOB SITE, FIRE HYDRANTS WERE OBSERVED IN USE. UPON REQUEST, NO DEP PERMIT WAS PROVIDED. UNAUTHORIZED USE OF FIRE HYDRANTS CREATES A HAZARDOUS CONDITION. STOP ALL USE IM #39554744K | Mar 25, 2027 | $2,500 |
| May 20, 2026 | Unknown CLASS - 2 BC3303.3 WATCHPERSON 6 STORY NEW BUILDING, BUILDING APPROXIMATELY 19792 SQUARE FEET. SITE CLOSED AND THERE WERE NO CONSTRUCTION ACTIVITY. UPON SHOUTING AT PERIMETER AND BANGING ON FENCE AND DOOR TO ALERT WATCHP #39554427R | Aug 5, 2026 IN VIOLATION | $2,500 |
| May 20, 2026 | Construction CLASS - 2 OBSERVED JERSEY BARRIERS AT EXP#1 NOT AS PER MANUFACTURES SPECIFICATION. JERSEY BARRIERS NOT CONTINUOUSLY INTERLOCKED FILL WITH WATER/SAND WHICH POSES A POTENTIAL HAZARD BY ALLOWING UNINTENDED MOVEMENT OF THE #39554428Z | Aug 5, 2026 IN VIOLATION | $1,250 |
| May 4, 2026 | Construction CLASS - 2 OBSERVATION: @ EXPOSURE#1 SCAFFOLD ON NEEDLE BEAMS UPON MY REQUEST FOR NEEDLE BEAMS DRAWING NONE WAS PROVIDED/DISPLAYED. PSWO FOR NO MANUFACURE SPECS FOR NEEDLE BEAMS. STOP ALL SCAFFOLD WORK.PROVIDED MANUFACTUR #39553762J | Jul 8, 2026 DEFAULT | $6,250 |
| Mar 3, 2026 | Construction CLASS - 1 FAILURE TO INSTITUTE SAFETY EQUIP MEASURES OR TEMPORARY CONSTRUCTION-"NO GUARDRAIL". AS NOTED: AT TIME OF INSPECTION AT AN ACTIVE JOBSITE FOR A PROPOSED 6 STORY BUILDING ALREADY AT THE 3 FLOOR LEVEL. OBSERVED A #35726567L | Dec 22, 2026 | $5,000 |
| Feb 18, 2026 | Site Safety CLASS - 1 AT THE TIME OF MY INSPECTION OBSERVED ACTIVE SITE ERECTING STRUCTURAL STEEL BEAMS UPON REQUEST OBSERVED RED STEEL FABRICATOR MACHINE IN USE. SITE FAILED TO PROVIDE MANUFACTURER SPECIFICATIONS(3301.6) FOR DIESEL #39550497Y | Dec 10, 2026 | $2,500 |
| Oct 11, 2025 | Unknown CLASS - 2 AT TIME OF INSPECTION, NO WATCHPERSON PRESENT ON SITE AS REQUIRED; CONTRARY TO BC 3303.3, ONCE THE FOUNDATION IS POURED, SITES EXCEEDING 5,000 SQ FT MUST MAINTAIN A COMPETENT WATCHPERSON DURING ALL NON-WORKING #39545861P | Mar 16, 2027 PENDING | $2,500 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Mar 6, 2026 | Energy Grade - LL33 FTP-EN-EGRDEA FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER AD CODE SEC. 28-309.12.3 | Active |
| Mar 6, 2026 | Benchmarking - LL84 FTF-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
| Dec 3, 2025 | Benchmarking - LL84 FTF-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
| Sep 26, 2025 | Benchmarking - LL84 FTF-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
| Jan 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle D (premises is in Community District 15) | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)