6 floors · 53 apartments · 33,930 sq ft · built 1900 · class C7 · owner of record: Derby Marbles 188, Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 42 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 42 days | Annual |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-09-10 (Accepted). Agency page | Dec 31, 2026 in 42 days | 2 of 2 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 58 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 33,930 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 163 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 163 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 286 days | Registered through 2027-09-01 |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1138 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jan 16, 2025 | Construction CLASS - 1 ATOI, OBSERVED IN COMMON HALLWAYS AND STAIRS - DUST AND DEBRIS. ON APT 1FN AND 1FS, OBSERVED DOORS COVERED WITH DUST. HALLWAYS HAVE DUST ON THE FLOOR. RESPONDENT HAS FAILED TO COMPLY WITH THE TPP WHICH STATES T #39135710X | Nov 18, 2026 IN VIOLATION | $2,500 |
| Aug 21, 2024 | Construction CLASS - 1 UNLAWFUL ACT.FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER.NOTE:AT TIME OF INSPECTION RESPONDENT HAS FAILED TO COMPLY WITH PREVIOUS VIO#35683625N DATED AT 6-27-2024 REAVIRING TO REPAIR AND MAINTAIN EXTERIOR B #35686176K | Dec 18, 2025 IN VIOLATION | $0 |
| Aug 21, 2024 | Construction CLASS - 1 UNLAWFUL ACT.FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER.NOTE:AT TIME OF INSPECTION RESPONDENT HAS FAILED TO COMPLY WITH PREVIOUS VIO#35683626P DATED 6-27-2024 REQUIRING TO REPAIR SWARMP CONDITION IN A TIME #35686177M | Dec 18, 2025 IN VIOLATION | $0 |
| Jun 27, 2024 | Construction CLASS - 1 FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTE: HAZARDOUS CONDITIONS OBSERVED, (1)AT EXPOSURE #1/WEST FIRE ESCAPE CORROSION EFFECTING BRACKET AND TREAD. (2)CRACKED MASONRY JOINT AT 2ND STO #35683625N | Dec 18, 2025 ADMIT/IN-VIO | $0 |
| Jun 27, 2024 | Construction CLASS - 1 FAILURE TO REPAIR SWARMP CONDITION IN TIMELY MANNER. OWNER FAILED TO REPAIR(CRACKED MASONRY JOINT, CORROSION AT FIRE ESCAPE, FLAKING CORNICE) WITHIN THE TIME FRAME RECOMMENDED BY QEWI, QWEI CHRISTOPHER BEHAN RE #35683626P | Dec 18, 2025 ADMIT/IN-VIO | $0 |
| Jun 17, 2024 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH DEPARTMENT OF BUILDINGS CONTAINED IN VIOLATION #35679848Z DATED 03/04/2024. AS OF 06/17/2024, NO SUCH CERTIFICATE HAS BEEN PR #35685412Z | Sep 19, 2024 IN VIOLATION | $0 |
| Jun 17, 2024 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTE: (1)OBSERVED AT EXPOSURE #1(WEST ELEVATION) CRACKED MASONRY AND MORTAR JOINTS AT 2ND STORY, CORROSION ON FIRE ESCAPES AND METAL CORNICE AT RO #35685413K | Feb 4, 2025 IN VIOLATION | $0 |
| Mar 4, 2024 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING EXTERIOR WALLS FACADE AND APPURTENANCES. NOTE: OBSERVED AT EXPOOSURE 1 WEST ELEVATION SPALLING METAL/FLAKING COATING AT ROOF CORNICE. CRACK JOINT AT 2 FLOOR AND CORROSIONS/DAMAGED C #35679848Z | May 9, 2024 ADMIT/IN-VIO | $0 |
| Mar 4, 2024 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING EXTERIOR WALLS FACADE AND APPURTENANCES. OBSERVED AT EXPOSURE 1 WEST ELEVATION SPALLING/FLAKING OF PAINT AT ROOF CORNICE SPALLED/FLAKING COATING AT WINDOW SILL AND WINDOW LINTELS AT #35679849K | May 9, 2024 ADMIT/IN-VIO | $0 |
| Dec 9, 2022 | Local Law CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#900941.REMEDY:SUBMIT ACCEPTABLE REQUIRE #37024910X | Mar 2, 2023 DEFAULT | $0 |
| Oct 27, 2022 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES.NOTE:ATTHE TIME OF INSPECTION OBSERVED AT EX#1(EAST EL)SPALLING METAL CORNICESPALLING COATING WINDOWSILLS LINTEL ALS COATING SPALLED WINDOW FRM AND #35669432X | Jun 12, 2023 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #04886 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #04885 | DOB VIOLATION - ACTIVE |
| May 31, 2018 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017 #00098 | DOB VIOLATION - ACTIVE |
| May 31, 2018 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017 #00099 | DOB VIOLATION - ACTIVE |
| Sep 18, 2013 | CONSTRUCTION #EX102001AW | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| May 31, 2018 | Facades FISPNRF FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017 | Active |
| May 31, 2018 | Facades FISPNRF FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Nov 18, 2026 | C | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING HOOK AND EYE ENSTALLED AT BUILDING FRONT ENTRANCE DOOR , 1st STORY | Dec 2, 2026 |
| Oct 7, 2026 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING IN STORAGE CLOSET AT PUBLIC HALL, 2nd STORY | Jan 10, 2027 |
| Oct 7, 2026 | B | Apt 3F · § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ... IN THE ENTRANCE LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Nov 11, 2026 |
| Oct 7, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR LEADING TO CELLAR FROM REAR YARD AT CELLAR | Oct 13, 2026 |
| Aug 21, 2026 | B | Apt 3R · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE UPPER ESCUTCHEON PLATE AT RISER IN THE 1st BATHROOM FROM EAST LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Sep 25, 2026 |
| Aug 21, 2026 | C | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING HOOK AND EYE DEVICE AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY | Sep 4, 2026 |
| Aug 21, 2026 | C | Apt 3R · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT ENTRANCE DOOR IN THE ENTRANCE LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Sep 4, 2026 |
| Dec 3, 2024 | C | Apt 6F · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 6F, 6th STORY, APARTMENT AT WEST | Dec 17, 2024 |
| Dec 3, 2024 | C | Apt 6F · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM NORTH LOCATED AT APT 6F, 6th STORY, APARTMENT AT WEST | Dec 9, 2024 |
| Nov 26, 2024 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILING IN STORAGE CLOSET AT PUBLIC HALL, 2nd STORY | Mar 1, 2025 |
| Sep 10, 2007 | B | Apt 6F · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOODEN FLOOR AT STY WEST APT 6F , SECTION '' '' | Oct 15, 2007 |
| Sep 10, 2007 | A | Apt 2RN · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS & CEILINGS KITCHEN & REAR ROOM 2 STY REAR APT 2RN. LOCATED AT APT 2RN | Dec 14, 2007 |
| Date | Source | What | Now |
|---|---|---|---|
| Nov 18, 2026 | HPD C | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING HOOK AND EYE ENSTALLED AT BUILDING FRONT ENTRANCE DOOR , 1st STORY | Open |
| Oct 7, 2026 | HPD A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING IN STORAGE CLOSET AT PUBLIC HALL, 2nd STORY | Open |
| Oct 7, 2026 | HPD B | § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES GAS RANGE IN THE KITCHEN LOCATED AT APT 4F, 4th STORY | Closed |
| Oct 7, 2026 | HPD B | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ... IN THE ENTRANCE LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Oct 7, 2026 | HPD B | § 27-2005 ADM CODE PROVIDE LOWER WIRE MESH SCREEN AT SKYLIGHT AT BULKHEAD , 6th STORY | Closed |
| Oct 7, 2026 | HPD B | D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED LEAK NORTH WALL THROUGHOUT 5 STY REAR APT 5R. , SECTION '' '' | Closed |
| Oct 7, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RESISTANT MATERIALS ON EAST AND WEST WALL AT STORAGE CLOSET AT PUBLIC HALL, 2nd STORY | Closed |
| Oct 7, 2026 | HPD B | D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILINGS THROUGHOUT 5 STY REAR APT 5R. , SECTION '' '' | Closed |
| Oct 7, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR LEADING TO CELLAR FROM REAR YARD AT CELLAR | Open |
| Aug 21, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE UPPER ESCUTCHEON PLATE AT RISER IN THE 1st BATHROOM FROM EAST LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Open |
| Aug 21, 2026 | HPD C | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING HOOK AND EYE DEVICE AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY | Open |
| Aug 21, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT ENTRANCE DOOR IN THE ENTRANCE LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 19, 2026, 2:39 PM ET. BBL 1005040011.