Bronx · Block 2946 · Lot 1 · 10457

1876 Belmont Avenue

7 floors · 92 apartments · 72,044 sq ft · built 1992 · class D3 · owner of record: Pio/Vip Housing Development Fund Corpora Tion

12open violations
$14,375ECB/OATH penalties owed
1HPD class C (immediately hazardous)
47dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 47 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Energy audit and retro-commissioning (2026) Likely applies
Local Law 87 · Calendar year 2026
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2946). Agency page

Dec 31, 2026
in 47 days
Due this year
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 47 days
Annual
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-06-12 (Accepted). Agency page

Dec 31, 2026
in 47 days
2 of 2 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 63 days
Annual
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $304,000 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2027
in 99 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 72,044 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 168 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 168 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 291 days
Registered through 2027-09-01

Open violations

ECB / OATH (5) · $14,375 owed
IssuedViolationHearingBalance
Jan 22, 2026Construction CLASS - 1
AT TIME OF INSPECTION OBSERVED EXCAVATED AREA APPROX. 8 FEET DEEP. UPON FURTHER RESEARCH NOTICE NO EARTH WORK NOTIFICATION PRIOR THE COMMENCE OF EXCAVATION HAVE BEING CREATED AS PER DOB RECORDS. AS PER BC 3304.
#39549431N
Aug 21, 2026
IN VIOLATION
$2,500
Jan 22, 2026Construction CLASS - 1
AT TIME OF INSPECTION OBSERVED LARGE EXCAVATION APPROX. 8 FT DEEP. NO SUPPORT OF EXCAVATION AT ANY SIDE OF THIS EXCAVATION. ALSO OBSERVED CONCRETE SLAB BEING UNDERMINE. STOP ALL WORK UNDER THIS JOB APPLICATION,
#39549430L
Aug 21, 2026
IN VIOLATION
$5,000
Mar 1, 2024Construction CLASS - 2
AT TIME OF INSPECTION OBSERVED APT # 7N INSTATE OF DISREPAIR CONDITIONS WITH WATER DAMAGED ON LIVINGROOM & CLOSET CEILING AND WALL. ALSO OBSERVED WATER MARKS & BUBBLE LIVING ROOM WALL., REPAIR AND/OR REPLACE
#39107487Y
Nov 19, 2024
IN VIOLATION
$625
Dec 9, 2022Local Law CLASS - 2
FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE 9A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL & APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #913846.REMEDY:SUBMIT ACCEPTABLE REQUIRED TE
#37024745L
Jun 12, 2023
DEFAULT
$6,250
Mar 15, 2006Construction Hazardous
FAILURE TO PROVIDE PROTECTION AT SIDES OF EXCAVATION. CONSTR. PERMIT# 200993498NB ISSUED 11/02/05 EXCAVATION AT SITE HAS SHEER CUT APPROX 15'DEEP W/NO SHORING OR BRACING ON THE N/S & WEST SIDES OF LOT.
#34524524J
Jul 7, 2006
WRITTEN OFF
$0
DOB (2)
IssuedViolationStatus
Feb 22, 2022NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
#01723
DOB VIOLATION - ACTIVE
Dec 1, 2021FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2101562
DOB VIOLATION - ACTIVE
DOB NOW Safety (3)
IssuedViolationStatus
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
Feb 22, 2022Facades FISPNRF
FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
Active
Dec 1, 2021Energy Grade - LL33 FTP-EN-EGRDEA
Active
HPD (4) · C 1 · B 2 · A 1
IssuedClassViolationCorrect by
Nov 2, 2026BApt 7E · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT THE SINK IN THE KITCHEN LOCATED AT APT 7E, 7th STORY, 1st APARTMENT FROM SOUTH AT WESTDec 7, 2026
Oct 19, 2026C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH AT COMPACTOR CHUTE DOOR AT PUBLIC HALL, 4th STORYNov 2, 2026
Oct 19, 2026BApt 4F · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 2nd APARTMENT FROM SOUTH AT WESTNov 23, 2026
May 20, 2026AApt 6M · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE STOPPER AT BATHTUB IN THE BATHROOM LOCATED AT APT 6M, 6th STORY, 1st APARTMENT FROM NORTH AT EASTAug 23, 2026

Issued in the last 120 days

DateSourceWhatNow
Nov 2, 2026HPD B§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT THE SINK IN THE KITCHEN LOCATED AT APT 7E, 7th STORY, 1st APARTMENT FROM SOUTH AT WESTOpen
Oct 19, 2026HPD C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH AT COMPACTOR CHUTE DOOR AT PUBLIC HALL, 4th STORYOpen
Oct 19, 2026HPD B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ITS ASSEMBLY AT COMPACTOR CHUTE DOOR AT PUBLIC HALL, 4th STORYClosed
Oct 19, 2026HPD B§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 2nd APARTMENT FROM SOUTH AT WESTOpen
Aug 13, 2026HPD CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5L, 5th STORY, 7th APARTMENT FROM SOUTH AT WESTClosed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 10:39 PM ET. BBL 2029460001.