11 floors · 164 apartments · 165,295 sq ft · built 2020 · class RM · owner of record: Harrico Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 66 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 82 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 165,295 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 187 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 187 days | Annual filing |
| Facade inspection report (Cycle 10C) Applies Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. Agency page | Feb 21, 2029 in 849 days | Filing window not open yet |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1162 days | Next cycle year 2029 |
| Energy audit and retro-commissioning (2031) Likely applies Local Law 87 · Calendar year 2031 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2851). Agency page | Dec 31, 2031 in 1892 days | Next due 2031 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 1, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.OBSERVED EXCESSIVE HOLE PENETRATIONS THROUGHOUT BUILDING. HOLE BEING COVERED OVER OFFICES WITH VENT C #39206293J | Dec 18, 2026 PENDING | $1,250 |
| Aug 8, 2026 | Unknown CLASS - 2 FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION. AS NOTED: AT TIME OF INSPECTION ON AN OCCUPIED PARKING STRUCTURE CONSISTING OF 01 LEVEL BELOW GRADE, OBSERVED SPALLED/CRACKED/LOOSE SOFIT EDGE CONCRETE A #35730098J | Nov 16, 2026 PENDING | $1,250 |
| Aug 6, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING. AT TIME OF INSPECTION OBSERVED ACTIVE WATER INFILTRATION AND EXCESSIVE CONDENSATION THROUGHOUT THE PARKING GARAGE CEILING. CONCRETE CEILING ASSEMBLY EXHIBITED SIGNS OF MOISTURE-REL #39199584R | Jan 25, 2027 PENDING | $2,500 |
| Oct 17, 2025 | Elevators CLASS - 2 CLASS 2: IN-CAR HANDRAIL LOOSE, RE-SECURE. EMERGENCY PHONE INOPERATIVE - NO RESPONSE, PROVIDE 2 WAY COMMUNICATION. TOP OF CAR ROLLER GUIDES NOT FULLY ENGAGE WITH THE RAILS - CONDITION OBSERVED ON THE TOP FLOOR, #39164059Z | May 1, 2026 STIPULATION/IN-VIO | $315 |
| Oct 17, 2025 | Construction CLASS - 2 OBSERVED IN THE BASEMENT DEDICATED FIRE LINE TIED INTO DOMESTIC WATER LINE. SPRINKLER HEADS OBSTRUCTED BY PAINTED CAPS THROUGHOUT THE BUILDING. ALSO REDUCING WASTE LINES GOING BACK TO STACK AND USING FURNCO COU #39164055L | Feb 1, 2027 PENDING | $1,250 |
| Oct 17, 2025 | Elevators CLASS - 2 CLASS 2: EMERGENCY PHONE INOPERATIVE - NO RESPONSE, PROVIDE 2 WAY COMMUNICATION. IN-CAR HANDRAIL LOOSE, SECURE. STANDING WATER IN THE PIT, REMOVE. DURING INSPECTION TOP FLOOR CAR CALL PLACED INSIDE THE CAR CANC #39164060X | May 1, 2026 STIPULATION/IN-VIO | $315 |
| Nov 26, 2024 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED CARBON MONOXIDE LEAK AT ROOF LEVEL PER BC 915, MC 804, PC 102.3, MAINTENANCE INSTALLATIONS, BOTH EXISTING AND NEW, AND PARTS THEREOF SHALL BE MAIN #39131375J | Jul 15, 2025 IN VIOLATION | $1,250 |
| Nov 26, 2024 | Construction CLASS - 1 OBSERVED OBSTRUCTED SPRINKLER HEAD IN THE REFUSE ROOM LOCATED ON THE 11 FLOOR. AS PER 102.3 OF THE PC INSTALLATIONS, BOTH EXISTING AND NEW, AND PARTS THEREOF SHALL BE MAINTAINED IN PROPER OPERATING CONDITION IN #39131382H | Jul 15, 2025 IN VIOLATION | $1,250 |
| Nov 26, 2024 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE. OBSERVED UNPERMITTED FOAM AND HOLE PENETRATIONS AT ROOF LEVEL IN BOILER ROOM. IN #39131374H | Jul 15, 2025 IN VIOLATION | $6,250 |
None open.
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Oct 8, 2026 | C | Apt 516 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 516, 5th STORY, 5th APARTMENT FROM NORTH AT EAST | Nov 3, 2026 |
| Oct 8, 2026 | B | Apt 516 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE DOOR TO BASE CABINET AT WEST WALL IN THE KITCHEN LOCATED AT APT 516, 5th STORY, 5th APARTMENT FROM NORTH AT EAST | Nov 12, 2026 |
| Oct 8, 2026 | B | Apt 516 · 566 (B) 27-2021.4 HMC: ABATE THE NUISANCE CONSISTING OF PESTS. EVIDENCE OF GNATS IN THE ENTIRE APARTMENT LOCATED AT APT 516, 5th STORY, 5th APARTMENT FROM NORTH AT EAST | Nov 12, 2026 |
| Jul 9, 2026 | B | Apt 1003 · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES , MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1003, 10th STORY, 2nd APARTMENT FROM WEST AT NORTH | Aug 13, 2026 |
| Jul 9, 2026 | C | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF AN UNACCEPTABLE TWO MOTION ELECTROMAGNETIC LOCKING DEVICE INSTALLED AT BUILDING ENTRANCE DOOR (FROM STREET TO VESTIBULE) , 1st STORY | Jul 15, 2026 |
| Jul 9, 2026 | B | § 27-2005 ADM CODE PROVIDE SECURITY IN THE EVENT OF A POWER OUTAGE BY MEANS OF AN ACCEPTABLE MECHANICAL HEAVY DUTY LOCK AND ASSEMBLIES AT BUILDING ENTRANCE DOOR (FROM STREET TO VESTIBULE) , 1st STORY | Aug 13, 2026 |
| Jul 9, 2026 | C | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF AN UNACCEPTABLE TWO MOTION ELECTROMAGNETIC LOCKING DEVICE INSTALLED AT DOOR (FROM VESTIBULE TO PUBLIC HALL) , 1st STORY | Jul 15, 2026 |
| Jul 9, 2026 | B | Apt 1003 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL BUZZER INTERCOM SYSTEM FROM BUILDING ENTRANCE DOOR TO THE APARTMENT WALL PANEL AT SOUTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 1003, 10th STORY, 2nd APARTMENT FROM WEST AT NORTH | Aug 13, 2026 |
| Jul 9, 2026 | B | Apt 1003 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DOORKNOB AT ENTRANCE IN THE BATHROOM LOCATED AT APT 1003, 10th STORY, 2nd APARTMENT FROM WEST AT NORTH | Aug 13, 2026 |
| Jul 9, 2026 | B | Apt 1003 · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS , MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1003, 10th STORY, 2nd APARTMENT FROM WEST AT NORTH | Aug 13, 2026 |
| Jul 9, 2026 | B | Apt 1003 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 1003, 10th STORY, 2nd APARTMENT FROM WEST AT NORTH | Aug 13, 2026 |
| Jul 9, 2026 | B | Apt 1003 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 1003, 10th STORY, 2nd APARTMENT FROM WEST AT NORTH | Aug 13, 2026 |
| Jul 9, 2026 | B | Apt 1003 · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRICAL OUTLET COVER PLATE AT SOUTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 1003, 10th STORY, 2nd APARTMENT FROM WEST AT NORTH | Aug 13, 2026 |
| Oct 7, 2024 | C | Apt 805 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INTERIOR GLASS PANE AT PATIO DOOR IN THE 2nd ROOM FROM EAST LOCATED AT APT 805, 8th STORY, 3rd APARTMENT FROM WEST AT NORTH | Oct 13, 2024 |
| Oct 7, 2024 | C | Apt 805 · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 4, WG TO REPLACE = 0, WG TO REPAIR = 0 IN THE ENTIRE APARTMENT LOCATED AT APT 805, 8th STORY, 3rd APA | Nov 2, 2024 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 8, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 516, 5th STORY, 5th APARTMENT FROM NORTH AT EAST | Open |
| Oct 8, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE DOOR TO BASE CABINET AT WEST WALL IN THE KITCHEN LOCATED AT APT 516, 5th STORY, 5th APARTMENT FROM NORTH AT EAST | Open |
| Oct 8, 2026 | HPD B | 566 (B) 27-2021.4 HMC: ABATE THE NUISANCE CONSISTING OF PESTS. EVIDENCE OF GNATS IN THE ENTIRE APARTMENT LOCATED AT APT 516, 5th STORY, 5th APARTMENT FROM NORTH AT EAST | Open |
| Oct 1, 2026 | ECB | Construction: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.OBSERVED EXCESSIVE HOLE PENETRATIONS THROUGHOUT BUILDING. HOLE BEING COVERED OVER OFFICES WITH VENT C | Open |
| Aug 8, 2026 | ECB | Unknown: FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION. AS NOTED: AT TIME OF INSPECTION ON AN OCCUPIED PARKING STRUCTURE CONSISTING OF 01 LEVEL BELOW GRADE, OBSERVED SPALLED/CRACKED/LOOSE SOFIT EDGE CONCRETE A | Open |
| Aug 6, 2026 | ECB | Construction: FAILURE TO MAINTAIN BUILDING. AT TIME OF INSPECTION OBSERVED ACTIVE WATER INFILTRATION AND EXCESSIVE CONDENSATION THROUGHOUT THE PARKING GARAGE CEILING. CONCRETE CEILING ASSEMBLY EXHIBITED SIGNS OF MOISTURE-REL | Open |
| Jul 9, 2026 | HPD B | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES , MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1003, 10th STORY, 2nd APARTMENT FROM WEST AT NORTH | Open |
| Jul 9, 2026 | HPD C | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF AN UNACCEPTABLE TWO MOTION ELECTROMAGNETIC LOCKING DEVICE INSTALLED AT BUILDING ENTRANCE DOOR (FROM STREET TO VESTIBULE) , 1st STORY | Open |
| Jul 9, 2026 | HPD B | § 27-2005 ADM CODE PROVIDE SECURITY IN THE EVENT OF A POWER OUTAGE BY MEANS OF AN ACCEPTABLE MECHANICAL HEAVY DUTY LOCK AND ASSEMBLIES AT BUILDING ENTRANCE DOOR (FROM STREET TO VESTIBULE) , 1st STORY | Open |
| Jul 9, 2026 | HPD C | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF AN UNACCEPTABLE TWO MOTION ELECTROMAGNETIC LOCKING DEVICE INSTALLED AT DOOR (FROM VESTIBULE TO PUBLIC HALL) , 1st STORY | Open |
| Jul 9, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1003, 10th STORY, 2nd APARTMENT FROM WEST AT NORTH | Closed |
| Jul 9, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL BUZZER INTERCOM SYSTEM FROM BUILDING ENTRANCE DOOR TO THE APARTMENT WALL PANEL AT SOUTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 1003, 10th STORY, 2nd APARTMENT FROM WEST AT NORTH | Open |
| Jul 9, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DOORKNOB AT ENTRANCE IN THE BATHROOM LOCATED AT APT 1003, 10th STORY, 2nd APARTMENT FROM WEST AT NORTH | Open |
| Jul 9, 2026 | HPD B | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS , MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1003, 10th STORY, 2nd APARTMENT FROM WEST AT NORTH | Open |
| Jul 9, 2026 | HPD C | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE HEAVY DUTY MORTISE LOCK AND ASSEMBLIES AT DOOR IN THE ENTRANCE LOCATED AT APT 1003, 10th STORY, 2nd APARTMENT FROM WEST AT NORTH | Closed |
| Jul 9, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1003, 10th STORY, 2nd APARTMENT FROM WEST AT NORTH | Closed |
| Jul 9, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 1003, 10th STORY, 2nd APARTMENT FROM WEST AT NORTH | Open |
| Jul 9, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 1003, 10th STORY, 2nd APARTMENT FROM WEST AT NORTH | Open |
| Jul 9, 2026 | HPD B | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRICAL OUTLET COVER PLATE AT SOUTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 1003, 10th STORY, 2nd APARTMENT FROM WEST AT NORTH | Open |
| Jul 9, 2026 | HPD C | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE , DETACHED CASEMENT WINDOW FRAME AT 2ND WINDOW FROM EAST AT NORTH WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 1003, 10th STORY, 2nd APARTMENT FROM WEST AT NORTH | Closed |
| Jul 9, 2026 | HPD C | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 1, WG TO REPLACE = 0, WG TO REPAIR = 0 IN THE ENTIRE APARTMENT LOCATED AT APT 1003, 10th STORY, 2nd A | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 26, 2026, 1:52 AM ET. BBL 2028517501.