Brooklyn · Block 2432 · Lot 30 · 11211

185 South 4 Street

12 floors · 42 apartments · 71,392 sq ft · built 2005 · class D4 · owner of record: 185 South 4th, Llc

31open violations
$6,560ECB/OATH penalties owed
7HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 46 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 46 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 62 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 71,392 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 167 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 167 days
Annual filing
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 777 days
Next cycle year 2028
Facade inspection report (Cycle 10C) Applies
Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $162,000 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2029
in 829 days
Filing window not open yet
Energy audit and retro-commissioning (2032) Likely applies
Local Law 87 · Calendar year 2032
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2432). Agency page

Dec 31, 2032
in 2238 days
Next due 2032
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-05-22 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (10) · $6,560 owed
IssuedViolationHearingBalance
Jul 31, 2026Elevators CLASS - 1
CLASS 1 CEASE USE: DOOR ZONE RESTRICTOR DEVICE FOUND INOPERATIVE AS PER CODE ASME A17.1/CSA B44 - SECTION 2.26.5. ELEVATOR CAR DOORS CAN BE OPENED WHEN THE CAR IS NOT WITHIN THE DESIGNATED DOOR ZONE, CREATING A
#39198702Y
Oct 14, 2026
IN VIOLATION
$1,250
Jul 31, 2026Elevators CLASS - 2
CLASS 2: IN-CAR DIRECTIONAL ARROWS FIXTURE DAMAGED AS PER ASME A17.1 8.6. REMEDY: REPAIR OR REPLACE FIXTURE AND RESTORE PROPER OPERATION. ELEVATOR CAB PRODUCES INTERMITTENT CLIPPING-TYPE NOISES WHILE TRAVELLING
#39198701M
Oct 14, 2026
STIPULATION/IN-VIO
$310
Jan 30, 2026Elevators CLASS - 1
CLASS 1(CU):FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION,DOOR ZONE RESTRICTOR INOPERATIVE ON ELEVATOR INOPERATIVEREPAIR THE DEVICE
#39175542M
May 4, 2027
DEFAULT
$0
Sep 8, 2025Construction CLASS - 2
FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH DEPARTMENT OF BUILDING FOR SUMMONS 39120129K., FILE A CERTIFICATE OF CORRECTION
#39159511J
Jul 16, 2026
IN VIOLATION
$1,250
Jan 13, 2025Construction CLASS - 1
28-323.8 AND RCNY 103-13(5). FAILURE TO SECURE PUBLIC SAFETY AND/OR MAKE THE BUILDING'S STRUCTURES AND APPURTENANCES CONFORM TO THE PREVIOUSOF ADMIN CODE AFTER UNSAFE NOTIFICATION FILED BY QPSI #UNPS-B0005029-1
#35690036K
Jul 10, 2026
IN VIOLATION
$2,500
Jul 29, 2024Construction CLASS - 1
AT TIME OF INSPECTION OBSERVED AT THE GARAGE TEMPORARY SHORING INSTALLED FOR I-BEAMS AND BEAMS POCKETING EXPOSED/OPEN. JOB # B01084914 FILED FOR TEMPORARY SHORING BUT NOT PERMITTED YET., OBTAIN PERMIT
#39120129K
Oct 2, 2024
ADMIT/IN-VIO
$0
Mar 1, 2024Elevators CLASS - 2
REPAIR IN-CAR EMERGENCY PHONE., PROVIDE IN-CAR MIRROR., RELOCATE MOTOR ROOM FIRE EXTINGUISHER TO A MORE VISIBLE LOCATION., REPAIR PIT LIGHT., SHORTEN HOIST ROPES TO PROVIDE MINIMUM OF 6 INCHES OF CLEARANCE BET
#39107418K
May 8, 2024
STIPULATION/IN-VIO
$0
Jan 24, 2024Elevators CLASS - 2
REPLACE WORN GIBS WHERE NEEDED. SECURE GIBS WHERE NEEDED. INOPERATIVE CAR PHONE. EXPIRED BRAKE MAINTENANCE TAG.PROVIDE INFO AND KEYS IN ORDER TO GAIN ENTRY TO RROF AND OVERHEAD. CONTROLLER ROOM UNLOCKED.
#39104200Y
Apr 3, 2024
STIPULATION/IN-VIO
$0
May 9, 2022Elevators CLASS - 1
97X17: DEVICE WAS FOUND OUT OF SERVICE IN THE LOBBY WITH THE DOOR CLOSE. NOT RESPONDING TO THE HALL CALLS. RESTORE TO SERVICE IMMEDIATELY AND CONTACT NYCDOB. AT EIR@BUILDINGS.NYC.GOV FOR A COMPLETE INSPECTION.
#38273867N
Nov 23, 2022
DEFAULT
$0
Feb 13, 2020Local Law CLASS - 2
FAILURE TO SUBMIT A REQUIRED CYCLE 8C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS & APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#814427. REMEDY: SUBMIT ACCEPTABLE REQUIRED TECHNICA
#37018531P
Nov 22, 2021
IN VIOLATION
$1,250
DOB (4)
IssuedViolationStatus
Dec 1, 2024FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2401204
DOB VIOLATION - ACTIVE
Dec 1, 2022FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2201207
DOB VIOLATION - ACTIVE
Dec 1, 2021FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2102400
DOB VIOLATION - ACTIVE
May 3, 2012FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#02048
DOB VIOLATION - ACTIVE
DOB NOW Safety (9)
IssuedViolationStatus
Oct 29, 2026Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction
Active
Oct 29, 2026Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction
Active
Sep 30, 2026AEUHAZ FTC-AEU-HAZ
Active
Jan 8, 2026Gas Piping - LL152 FTF-PL-PER
Cycle 2, Sub-cycle A (premises is in Community District 1)
Active
Dec 31, 2024Parking Structures FTC-PS-UNSAFE
Unsafe report of parking structures filed.
Active
Dec 1, 2024Energy Grade - LL33 FTP-EN-EGRDEA
Active
Dec 1, 2022Energy Grade - LL33 FTP-EN-EGRDEA
Active
Dec 1, 2021Energy Grade - LL33 FTP-EN-EGRDEA
Active
May 3, 2012Benchmarking - LL84 FTF-EN-BENCH
Active
HPD (12) · C 7 · B 4 · A 1
IssuedClassViolationCorrect by
Nov 9, 2026CApt 10A · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 10A, 10th STORY, 1st APARTMENT FROM SOUTH AT WESTNov 9, 2026
Nov 9, 2026CApt 10B · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 10B, 10th STORY, 3rd APARTMENT FROM EAST AT SOUTHNov 8, 2026
Nov 4, 2026CApt 11D · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 11D, 11th STORY, 1st APARTMENT FROM NORTH AT EASTNov 3, 2026
Oct 14, 2026CApt 11A · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 11A, 11th STORY, 1st APARTMENT FROM WEST AT NORTHOct 28, 2026
Mar 16, 2026BApt 11A · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 11A, 11th STORY, 1st APARTMENT FROM WEST AT NORTHApr 20, 2026
Mar 16, 2026CApt 11A · § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING CONSISTING OF DOOR SWEEP AT DOOR IN THE ENTRANCE LOCATED AT APT 11A, 11th STORY, 1st APARTMENT FROM WEST AT NORTHMar 30, 2026
Mar 16, 2026BApt 11A · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 11A, 11th STORY, 1st APARTMENT FROM WEST AT NORTHApr 20, 2026
Mar 16, 2026CApt 11A · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 7; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 11A, 11th STORY, 1st AApr 11, 2026
Mar 13, 2026CApt 7C · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONSISTING OF PAINTED SPRINKLER HEAD AT EAST WALL IN THE KITCHEN LOCATED AT APT 7C, 7th STORY, 2nd APARTMENT FROM SOUTH AT WESTMar 19, 2026
Dec 19, 2023BApt 8B · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 4 SQUARE FT AT CEILING IN THE BATHROOM LOCATED AT APT 8B, 8th STORY, 3rd APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 16172721 ISSUED 18-AUG-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §Jan 23, 2024
Feb 23, 2023BApt 11A · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOODEN FLOOR (UNEVEN) IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 11A, 11th STORY, 1st APARTMENT FROM WEST AT NORTHMar 30, 2023
Dec 12, 2019A§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SAFETY CAPS ON ELECTRICAL OUTLET AT SOUTH WALL AT PUBLIC HALL, 11th STORYMar 16, 2020

Issued in the last 120 days

DateSourceWhatNow
Nov 9, 2026HPD C§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 10A, 10th STORY, 1st APARTMENT FROM SOUTH AT WESTOpen
Nov 9, 2026HPD C§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 10B, 10th STORY, 3rd APARTMENT FROM EAST AT SOUTHOpen
Nov 4, 2026HPD C§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 11D, 11th STORY, 1st APARTMENT FROM NORTH AT EASTOpen
Oct 29, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of CorrectionOpen
Oct 29, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of CorrectionOpen
Oct 14, 2026HPD C§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 11A, 11th STORY, 1st APARTMENT FROM WEST AT NORTHClosed
Oct 14, 2026HPD C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 11A, 11th STORY, 1st APARTMENT FROM WEST AT NORTHOpen
Sep 30, 2026DOB SafetyAEUHAZ: Closed
Sep 30, 2026DOB SafetyAEUHAZ: Open
Jul 31, 2026ECBElevators: CLASS 1 CEASE USE: DOOR ZONE RESTRICTOR DEVICE FOUND INOPERATIVE AS PER CODE ASME A17.1/CSA B44 - SECTION 2.26.5. ELEVATOR CAR DOORS CAN BE OPENED WHEN THE CAR IS NOT WITHIN THE DESIGNATED DOOR ZONE, CREATING AClosed
Jul 31, 2026ECBElevators: CLASS 2: IN-CAR DIRECTIONAL ARROWS FIXTURE DAMAGED AS PER ASME A17.1 8.6. REMEDY: REPAIR OR REPLACE FIXTURE AND RESTORE PROPER OPERATION. ELEVATOR CAB PRODUCES INTERMITTENT CLIPPING-TYPE NOISES WHILE TRAVELLINGClosed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 15, 2026, 7:49 AM ET. BBL 3024320030.

Look up another building