5 floors · 46 apartments · 40,150 sq ft · built 1928 · class D5 · owner of record: Andrews Plaza Housing Associates
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 51 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 51 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 67 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 40,150 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 172 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 172 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 295 days | Registered through 2027-09-01 |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1147 days | Next cycle year 2029 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-05-28 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Dec 19, 2023 | Construction CLASS - 2 IN APT 3C, IN HALLWAY, STRESS CRACKS APPEAR,ALSO NOTED FLOOR SAGS AND IS NOT LEVEL., REPAIR AND/OR REPLACE #39101760Z | Jun 24, 2027 | $3,125 |
| Sep 18, 2020 | Elevators CLASS - 1 NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS PER 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. REMEDY; INSTALL DLM AND, PERFORM AND FILE TEST WITH NYCDOB. GOVERNOR ROPE RUSTED. MOTOR ROOM DOOR DAMAGED, W #39028895H | Jan 15, 2021 IN VIOLATION | $3,125 |
| Jan 29, 2020 | Elevators CLASS - 1 CLASS 1 - NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS A CONTROLLER FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY; FILE APPLICATION, INS #39016539N | Dec 4, 2020 IN VIOLATION | $1,250 |
| Jun 28, 2010 | Construction CLASS - 2 FAILURE TO COMPLY W/ THE COMM ORDER TO FILE CERT OF CORRECTIONS W/ THE DOB FOR ALL OVERDUE &/OR NO COMPLIANCE OPEN ECB VIOLATIONS REM: FILE CERT OF CORRECTION #34850963P | Aug 20, 2010 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Dec 1, 2023 | FAILURE TO POST ENERGY GRADE/SCORE FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 #2300722 | DOB VIOLATION - ACTIVE |
| Feb 22, 2022 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022 #00872 | DOB VIOLATION - ACTIVE |
| Dec 9, 2020 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00220 | DOB VIOLATION - ACTIVE |
| Sep 2, 2020 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #02229 | DOB VIOLATION - ACTIVE |
| Sep 6, 2019 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST #03760 | DOB VIOLATION - ACTIVE |
| May 31, 2018 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017 #00440 | DOB VIOLATION - ACTIVE |
| Aug 15, 2012 | ELEVATOR #ACC101263 | DOB VIOLATION - ACTIVE |
| Jun 29, 1990 | LOCAL LAW 10/81 - ELEVATOR 1 #02623 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Dec 1, 2023 | Energy Grade - LL33 FTP-EN-EGRDEA | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction | Active |
| Oct 2, 2023 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction | Active |
| Feb 22, 2022 | Facades FISPNRF CYCLE 9A NO REPORT FILED | Active |
| Dec 9, 2020 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 2, 2020 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 6, 2019 | Elevators ACC1 | Active |
| May 31, 2018 | Facades FISPNRF FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017 | Active |
| Aug 15, 2012 | Elevators E | Active |
| Jun 29, 1990 | Elevators LL1081 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 30, 2026 | B | Apt 2G · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET COVER PLATE AT WEST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2G, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST | Nov 4, 2026 |
| Sep 30, 2026 | C | Apt 2G · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK AT DOOR LEADING TO ROOM WITH SECONDARY EXIT WINDOW IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 2G, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST | Oct 6, 2026 |
| Sep 30, 2026 | B | Apt 2G · § 27-2005 HMC: REFIT DOORS AT CLOSET, 1ST FROM EAST AT SOUTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2G, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST | Nov 4, 2026 |
| Jun 2, 2026 | B | Apt 4A · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 4A, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST | Jul 7, 2026 |
| Jun 2, 2026 | C | Apt 4A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST | Jun 28, 2026 |
| Jun 1, 2026 | C | Apt 4A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 3rd APARTMENT FROM NORTH AT EAST | Jun 27, 2026 |
| Jun 1, 2026 | B | Apt 4A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SINK BASE CABINET DOOR IN THE KITCHEN LOCATED AT APT 4A, 4th STORY, 3rd APARTMENT FROM NORTH AT EAST | Jul 6, 2026 |
| Mar 9, 2026 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN VESTIBULE AT PUBLIC HALL, 1st STORY | Jun 12, 2026 |
| Mar 9, 2026 | B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN VESTIBULE AT PUBLIC HALL, 1st STORY | Apr 13, 2026 |
| Sep 29, 2025 | B | Apt 4A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AT DOOR IN THE ENTRANCE LOCATED AT APT 4A, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 3, 2025 |
| Mar 26, 2024 | B | Apt 2G · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 20 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 2G, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST | Apr 30, 2024 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
| Sep 30, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET COVER PLATE AT WEST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2G, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST | Open |
| Sep 30, 2026 | HPD C | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK AT DOOR LEADING TO ROOM WITH SECONDARY EXIT WINDOW IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 2G, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST | Open |
| Sep 30, 2026 | HPD B | § 27-2005 HMC: REFIT DOORS AT CLOSET, 1ST FROM EAST AT SOUTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2G, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 10, 2026, 1:09 PM ET. BBL 2028790149.