Bronx · Block 2949 · Lot 72 · 10457

1821 Prospect Avenue

7 floors · 33 apartments · 17,620 sq ft · built 2022 · class D1 · owner of record: Pro 1821 Llc

1open violations
$16,875ECB/OATH penalties owed
0HPD class C (immediately hazardous)
62dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 62 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 62 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 62 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 78 days
Annual
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page

Feb 21, 2027
in 114 days
No Cycle 10 report on record yet
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 306 days
Registered through 2027-09-01

Open violations

ECB / OATH (8) · $16,875 owed
IssuedViolationHearingBalance
May 19, 2023Construction CLASS - 2
AT TIME OF INSPECTION, OBSERVED A CREW WORKING ON SUPPORTED AND SUSPENDED SCAFFOLD. UPON REVIEWING SST CARDS FOUND ONE WORKERS WITHOUT A TRAINING CONNECT ISSUE CARD, REQUIRE AFTER MARCH 18 2023. ALSO ONE WORKER
#39516869R
Aug 4, 2023
IN VIOLATION
$625
May 19, 2023Construction CLASS - 1
FAILURE TO MAINTAIN SUPPORTED SCAFFOLD IN CODE COMPLYING MANNER. AT TIME OF INSPECTION, OBSERVED SUPPORTED SCAFFOLD NOT CONSTRUCTED AS PER DRAWINGS AND NOT MAINTAIN PER CODE. OBSERVED AT EXPOSURE 1 ON 7 FLOOR S
#39516834R
Aug 4, 2023
IN VIOLATION
$625
Feb 15, 2023Unknown CLASS - 1
AT TIME OF INSPECTION UPON REQUEST TOO SEE SITE SPECIFIC ORIENTATION FOR ALL WORKERS NONE WAS PROVIDED. FAILURE TO INFORM AND TRAIN ALL WORKERS FOR SITE SPECIFIC CONDITIONS AND PRECAUTIONS TO BE TAKEN TOO PREVE
#39513190R
Jun 18, 2024
IN VIOLATION
$5,000
Feb 15, 2023Construction CLASS - 1
AT TIME OF INSPECTION I OBSERVED GUARDRAIL SYSTEM INADEQUATELY INSTALLED AND MAINTAIN CREATING A HAZARDOUS CONDITION FOR WORKERS AND PERSONS ACCESSING THAT AREA FROM POTENTIAL FALLING CONDITION RESULTING IN INJ
#39513184K
Oct 17, 2023
IN VIOLATION
$2,500
Feb 15, 2023Construction CLASS - 1
MATERIAL STORAGE. AT TIME OF INSPECTION I OBSERVED WASTE LINE PIPES STORED WITHIN 5 FEET OF LEADING EDGE AT 6 TH STORY LOOSE AND NOT PROPERLY SECURED CREATING A HAZARD OF POTENTIAL ROLL OFF BUILDING HITTING PER
#39513188H
Oct 17, 2023
IN VIOLATION
$2,500
Feb 15, 2023Construction CLASS - 1
DROPPING OR THROWING PROHIBITED. AT TIME OF INSPECTION I OBSERVED FROM SCHOOL YARD A WORKER THROWING WOOD DEBRIS FROM 3 RD STORY INTO REAR YARD AT EXPO 3.PROVIDE TOOL BOX TALK FOR PROPER HOUSEKEEPING AND DEBRIS
#39513187X
Oct 17, 2023
IN VIOLATION
$2,500
Feb 15, 2023Construction CLASS - 1
AT TIME OF INSPECTION I OBSERVED A LARGE AMOUNT OF DEBRIS PILED HIGH AT EXPO 3 CONSISTING OF PLYWOOD AND OTHER WOOD DEBRIS CREATING A POTENTIAL FIRE HAZARD WHICH CAN AFFECT ADJACENT PROPERTY AND CAUSE PROPERTY
#39513186Y
Oct 17, 2023
IN VIOLATION
$2,500
Jun 7, 2022Site Safety CLASS - 1
FAILURE TO MAINTAIN/DISPLAY ONSITE DOCUMENTS REQUIRED BY BC CHAPTER 33NON DOB APPROVED PLANS FOR FOUNDATION WORK ONSITE.NOTED:AT TIME OF INSPECTION OF A PROPOSED 7 STORY NB AT FOUNDATION PHASE ACTIVE SITE.I OBS
#35652678P
Dec 9, 2022
IN VIOLATION
$625
DOB (0)

None open.

DOB NOW Safety (1)
IssuedViolationStatus
Oct 2, 2026Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2025 Periodic Inspection Report
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Oct 2, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Periodic Inspection ReportOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 30, 2026, 2:31 PM ET. BBL 2029490072.