Bronx · Block 2881 · Lot 23 · 10453

1819 Sedgwick Avenue

5 floors · 9 apartments · 6,003 sq ft · built 2021 · class D1 · owner of record: Gabriel & Juliet Inc

14open violations
$31,250ECB/OATH penalties owed
1HPD class C (immediately hazardous)
50dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 50 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 50 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 66 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 294 days
Registered through 2027-09-01
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1146 days
Next cycle year 2029

Open violations

ECB / OATH (9) · $31,250 owed
IssuedViolationHearingBalance
Apr 18, 2023Construction CLASS - 1
4 STORY NB, ACTIVE SITE, WITH THE FOLLOWING VIOLATING CONDITIONS: 1)LIFELINES NOT PROTECTED-BC3314.6.2, 2)NO DEBRIS NETTING ON SUSP SF-3314.8.2, 3)USE OF LADDERS ON DROPS-1926.451(F)(14&15), 4) EXP1 DROP HAS 1
#39515517Z
Feb 6, 2024
DEFAULT
$6,250
Dec 30, 2022Construction CLASS - 2
AT TIME OF INSPECTION, OBSERVED APPROX. 10 WORKERS AT TOP LEVEL DOING MASONRY WORK ALSO SOME ON LOWER LEVEL. I CALLED MAKE SURE THEY WERE FULLY AWARE OF MY PRESENCE AND ASK THEM TO GRANT ACCESS. OBSERVED TO CHA
#39511014Z
Mar 17, 2023
IN VIOLATION
$1,250
Jul 13, 2022Construction CLASS - 2
AT THE TIME OF INSPECTION 5 STORIES NEW BUILDING I OBSERVED CONSTRUCTION FENCE AT EXP#1,3 AFTER SEARCH ON BIS, AND DOB NOW SYSTEM NO ACTIVE FN PERMIT.
#39503438M
Sep 2, 2022
DEFAULT
$3,125
Sep 15, 2021Construction CLASS - 1
FAILURE TO SAFEGUARD CONSTRUCTION SITE.AT TIME OF MY INSPECTION I OBSERVED AN ACTIVE JOBSITE WITH APPROX 6 WORKERS.A FOUNDATION PHASE PROPOSED NEW 5 STORY BUILDING.I NOTICED APPROX 25 REBAR THAT WERE EXPOSED MO
#35506365Z
Jan 14, 2022
IN VIOLATION
$5,000
Sep 15, 2021Construction CLASS - 1
FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING.AT TIME OF MY INSPECTION FORSAFETY COMPLIANCE AT A PROPOSED 5 STORY BUILDING AT FOUNDATION PHASE APPROX 6 WORKERS ONSITE.ACTIVE WORK IN PROGRESS.I NOTICED INADEQUATE HO
#35506363P
Jan 14, 2022
IN VIOLATION
$625
Jul 2, 2021Construction CLASS - 1
BC 3304.4.5 PLACING OF SOIL OF FOUNDATION WORK EQUIPMENT(EXCAVATOR)ANDEXCAVATED MATERIAL NOTE:AT THE TIME OF INSPECTION OBSERVED A 5 STY NB UNDER CONSTRUCTION AT EXCAVATION/FOUNDATION LEVEL.OBSERVED ABOUT 12 FE
#35575715Z
Jul 29, 2022
IN VIOLATION
$2,500
Jul 2, 2021Construction CLASS - 1
WORK CONTRARY TO SITE SAFETY PLAN NOTE:AT THE TIME OF INSPECTION OBSERVED A 5 STY NB UNDER CONSTRUCTION AT EXCAVATION/FOUNDATION LEVEL.OBSERVED AS PER SITE SAFETY PLAN(SSP)FENCE SUPPOSE TO BE ON PROPERTY LINE O
#35575717M
Jul 29, 2022
IN VIOLATION
$2,500
Jul 2, 2021Construction CLASS - 1
PROTECTION OF SIDES OF EXCAVATION-INADEQUATE.NOTE:AT THE TIME OF INSPECTION OBSERVED A 5 STY NEW BUILDING UNDER CONSTRUCTION AT EXCAVATION/FOUNDATION LEVEL.OBSERVED ABOUT 12 FEET DEEP EXCAVATED AREA WITH POURED
#35575716K
Jul 29, 2022
IN VIOLATION
$5,000
May 26, 2021Unknown CLASS - 1
PRE-SHIFT SAFETY MEETING LOG.AT TIME OF COMP INSPECTION AT NEW 5 STORYBUILDING ACTIVE JOBSITE WITH REMOVAL OF TREES,BRUSH SEEKING JOBSITE FENCE AND GRADING SLOPE OF RAMP FOR EXCAVATOR.UPON REQUEST TO SEE PRESHI
#35559381H
Apr 22, 2022
IN VIOLATION
$5,000
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (14) · C 1 · B 0 · A 13
IssuedClassViolationCorrect by
Jun 4, 2026A§27-2045(B)(5) HMC, § 12-01 RCNY POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAILBOX MISSING AT PUBLIC HALL, 1st STORYSep 7, 2026
Jun 4, 2026A§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING AT PUBLIC HALL, 1st STORYSep 7, 2026
Jun 4, 2026A§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORYSep 7, 2026
Jun 4, 2026A§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORYSep 7, 2026
Jun 4, 2026A§27-2045(B)(5) HMC, § 12-06, 12-10 RCNY POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN PRIVATE DWELLINGS MISSINGSep 7, 2026
Jun 4, 2026A§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORYSep 7, 2026
Jun 4, 2026CApt 2 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTJun 30, 2026
May 26, 2026A§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORYAug 29, 2026
May 26, 2026A§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORYAug 29, 2026
May 26, 2026A§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING AT PUBLIC HALL, 1st STORYAug 29, 2026
May 26, 2026A§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORYAug 29, 2026
May 26, 2026A§ 27-2022 ADM CODE POST A SIGN INDICATING HOURS OF COLLECTION AND METHOD OF COLLECTION OF WASTE MATERIAL WHERE DUMBWAITER SERVICE IS NOT PROVIDED. AT PUBLIC HALL, 1st STORYAug 29, 2026
May 26, 2026A§27-2045(B)(5) HMC, § 12-01 RCNY POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAILBOX IMPROPERLY DISPLAYED AT PUBLIC HALL, 1st STORYAug 29, 2026
May 26, 2026A§27-2045(B)(5) HMC, § 12-06, 12-10 RCNY POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN PRIVATE DWELLINGS IMPROPERLY DISPLAYEDAug 29, 2026

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 11, 2026, 6:51 PM ET. BBL 2028810023.

Look up another building