3 floors · 6 apartments · 5,775 sq ft · built 1930 · class C2 · owner of record: Sun Wing Realty Corp.
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 61 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 61 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 77 days | Annual |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 426 days | Next cycle year 2027 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-02-13 (Accepted). Agency page | On file | 2026 reports accepted |
None open.
| Issued | Violation | Status |
|---|---|---|
| Jun 1, 1994 | LOCAL LAW 62/91 - BOILERS #02641 | DOB VIOLATION - ACTIVE |
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #20546 | DOB VIOLATION - ACTIVE |
| Jun 1, 1993 | LOCAL LAW 62/91 - BOILERS #02640 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device | Active |
| Jun 1, 1994 | Boiler LL6291 | Active |
| Jun 1, 1993 | Boiler LL6291 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jan 12, 2016 | A | SECTION 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCY?S HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY | Apr 16, 2016 |
| Jan 12, 2016 | A | SECTION 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORY | Apr 16, 2016 |
| Jan 12, 2016 | C | SECTION 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM , AT PUBLIC HALL, 1st STORY | Jan 20, 2016 |
| Jan 12, 2016 | A | SECTION 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX , AT PUBLIC HALL, 1st STORY | Apr 16, 2016 |
| Jul 2, 2008 | B | SECTION 27-2081 ADM CODE DISCONTINUE USE OF ROOMS FOR LIVING, DISCONNECT PLUMBING FIXTURES AND PROPERLY SEAL PIPE CONNECTIONS .. AT BASEMENT | Aug 6, 2008 |
| Jun 5, 2008 | B | D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING BATHROOM 2 STY FRONT APT. | Jul 10, 2008 |
| Jun 5, 2008 | B | D26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE TILE WALL BATHROOM 2 STY FRONT APT. | Jul 10, 2008 |
| Jun 5, 2008 | B | D26-10.01, 10.05 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS PUBLIC HALL STAIR BULKHEAD TO ROOF. | Jul 10, 2008 |
| Jun 5, 2008 | B | D26-19.01 ADM CODE PROVIDE ADEQUATE LIGHTING FIRE PASSAGEWAY FRONT & REAR EAST. | Jul 10, 2008 |
| Jun 5, 2008 | B | D26-19.07 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING 50 WATTS FRONT. | Jul 10, 2008 |
| Jun 5, 2008 | B | D26-19.07 ADM CODE INSTALL AND MAINTAIN SUFFICIENT LIGHT OR LIGHTS OF AT LEAST 40 WATTS INCANDESCENT OR EQUIVALENT EACH, TO LIGHT ADEQUATELY FROM SUNSET TO SUNRISE THE REAR YARD. | Jul 10, 2008 |
| Jun 5, 2008 | B | D26-19.07 ADM CODE INSTALL AND MAINTAIN SUFFICIENT LIGHT OR LIGHTS OF AT LEAST 40 WATTS INCANDESCENT OR EQUIVALENT EACH, TO LIGHT ADEQUATELY FROM SUNSET TO SUNRISE THE INNER COURT EAST. | Jul 10, 2008 |
| Jun 5, 2008 | B | Apt 3A · D26-20.08,20.09 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING 3 STY APT 3A. , SECTION '' '' | Jul 10, 2008 |
| Jun 5, 2008 | B | D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED WATER LEAK CEILING BATHROOM 2 STY FRONT APT. | Jul 10, 2008 |
| Jun 5, 2008 | B | Apt 3F · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF MILDEW WALLS & CEILINGS 3 STY FRONT NORTH APT 3F THRU OUT. , SECTION '' '' | Jul 10, 2008 |
| Jun 5, 2008 | A | Apt 3F · SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS & CEILINGS 3 STY FRONT NORTH APT 3F THRU OUT. , SECTION '' '' | Sep 8, 2008 |
| Jun 5, 2008 | B | Apt 3F · SECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE TO 3 STY FRONT NORTH APT 3F. , SECTION '' '' | Jul 10, 2008 |
| Jun 5, 2008 | B | Apt 3F · SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS SINK 3 STY FRONT NORTH APT 3F KITCHEN. , SECTION '' '' | Jul 10, 2008 |
| Jun 5, 2008 | B | Apt 3F · SECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN ROACHES 3 STY FRONT NORTH APT 3F THRU OUT. , SECTION '' '' | Jul 10, 2008 |
| Jun 5, 2008 | A | Apt 3F · SECTION 27-2043 ADM CODE PROVIDE A LOCK AND KEY TO THE ENTRANCE DOOR OF DWELLING UNIT AND, IF A CL A MULTIPLE DWELLING, ALSO CHAIN DOOR GUARD 3 STY FRONT NORTH APT 3F. , SECTION '' '' | Sep 8, 2008 |
| Jun 5, 2008 | C | SECTION 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM 1 STY PUBLIC HALL & ON BOILER ROOM DOOR. | Jun 11, 2008 |
| Jun 5, 2008 | A | Apt 3A · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF MILDEW & MOLD WALLS 3 STY NORTH APT 3A FRONT ROOM. , SECTION '' '' | Sep 8, 2008 |
| Jun 5, 2008 | B | Apt 3A · D26-20.08,20.09 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING 3 STY APT 3A. , SECTION '' '' | Jul 10, 2008 |
| Jun 5, 2008 | B | Apt 3A · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE 3 STY NORTHWEST APT 3A RAMCHALITAR. LOCATED AT APT 3A | Jul 10, 2008 |
| Jun 5, 2008 | B | Apt 3A · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE 3 STY FRONT APT 3A RAMCHARITAR. , SECTION '' '' | Jul 10, 2008 |
| Jun 5, 2008 | A | Apt 3F · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING EXTERIOR COVER FOR PEEPHOLE ENTRANCE DOOR TO 3 STY FRONT NORTH APT 3F. , SECTION '' '' | Sep 8, 2008 |
| Jun 5, 2008 | A | Apt 2A · D26-16.01 ADM CODE REPAIR LEAKY WATER CLOSET FLUSH PIPE CONNECTION BATHROOM 2 STY FRONT APT 2A. LOCATED AT APT 2A | Sep 8, 2008 |