4 floors · 9 apartments · 14,100 sq ft · built 1927 · class C1 · owner of record: 1809 Beverly Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 69 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 69 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 85 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 313 days | Registered through 2027-09-01 |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 14 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 434 days | Next cycle year 2027 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-16 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Feb 4, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE.VIO#39143678P CONDITIONS STILL THE SAME. UPON INSPECTION AT CELLAR LEVEL, OBSERVED #39175907X | Jan 22, 2027 | $6,250 |
| Feb 4, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. VIO#39146810R CONDITIONS STILL EXIST.AT TIME OF INSPECTION, OBSERVED 4 STORY MULTI DWELLING BUILDING, RETAINING WALL APPROX. 9'H X 40' W AT THE REAR OF THE #39175914Y | Jan 22, 2027 PENDING | $12,500 |
| May 1, 2025 | Construction CLASS - 1 AT TIME OF INSPECTION, OBSERVED 4 STORY MULTI DWELLING BUILDING, RETAINING WALL APPROX. 9'H X 40' W AT THE REAR OF THE PROPERTY EXPOSURE 3, RETAINING WALL HORIZONTAL CRACKED AT THE TOP APPROX. 16' W AND SIGNS O #39146810R | Dec 28, 2026 DEFAULT | $25,000 |
| Apr 2, 2025 | Construction CLASS - 1 OBSERVED REMOVED GAS PIPING AT CELLAR AND ALSO GAS METERS REMOVED WITHOUT ANY PERMITS ON FILE AT THE DOB. AS PER 106.2 OF THE FGC ANY OWNER OR AUTHORIZED AGENT WHO INTENDS TO CONSTRUCT, ADD TO, ALTER, SHALL FIR #39143672Y | Dec 28, 2026 DEFAULT | $2,530 |
| Jan 10, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED CONCRETE RETAINING WALL AT EXPOSURE#3 WITH VERTICAL AND HORIZONTAL CRACKS. ALSO OBSERVED CONCRETE RETAINING WALL BULGING A #39135206R | Jan 8, 2027 PENDING | $655 |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #12652 | DOB VIOLATION - ACTIVE |
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #34949 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jan 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle D (premises is in Community District 14) | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Feb 2, 2026 | I | §27-2153 ADM CODE THE PREMISES HAS BEEN SELECTED TO PARTICIPATE IN THE ALTERNATIVE ENFORCEMENT PROGRAM WHICH MAY RESULT IN BUILDING-WIDE INSPECTIONS, FEES, AND EXTENSIVE REPAIR WORK TO CORRECT VIOLATIONS AND UNDERLYING CONDITIONS. CHARGES FOR REPAIR WORK DONE PURSUANT TO THIS ORDER, IF NOT PAID, WIL | — |
| Apr 8, 2026 | B | Apt 2W · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 4th ROOM FROM NORTH LOCATED AT APT 2W, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | May 13, 2026 |
| Mar 4, 2026 | C | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE RETAINING WALL AT REAR YARD | Mar 10, 2026 |
| Apr 7, 2025 | C | 567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, G | May 3, 2025 |
| Mar 14, 2025 | C | § 27-2005 ADM CODE MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT HORIZONTAL CRACK IN CEMENT RETAINER WALL AT NORTH IN REAR YARD | Mar 20, 2025 |
| Mar 14, 2025 | B | Apt 2E · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE CURTAIN ROD AT BATHTUB IN THE BATHROOM LOCATED AT APT 2E, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Apr 18, 2025 |
| Jan 21, 2025 | B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AT VESTIBULE DOOR , 1st STORY | Feb 25, 2025 |
| Jan 10, 2025 | B | Apt 2E · § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTE LINE UNDER WASH BASING IN THE BATHROOM LOCATED AT APT 2E, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Feb 14, 2025 |
| Oct 28, 2024 | B | Apt 3E · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GASKET AT REFRIGERATOR DOOR IN THE KITCHEN LOCATED AT APT 3E, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH | Dec 2, 2024 |
| Jan 18, 2023 | C | Apt 1W · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING, WEST WALL IN THE KITCHEN LOCATED AT APT 1W, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Feb 11, 2023 |
| Jan 18, 2023 | C | Apt 1W · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING, WEST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 1W, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Feb 11, 2023 |
| Jan 18, 2023 | C | Apt 1W · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING, NORTH WALL IN THE 3rd ROOM FROM NORTH AT WEST LOCATED AT APT 1W, 1st STORY, 1st APARTMENT FROM WEST AT NORT | Feb 11, 2023 |
| Jan 18, 2023 | C | Apt 1W · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING, SOUTH WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT 1W, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Feb 11, 2023 |
| Jan 18, 2023 | C | Apt 1W · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING IN THE 7th ROOM FROM NORTH LOCATED AT APT 1W, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Feb 11, 2023 |
| Date | Source | What | Now |
|---|---|---|---|
| Aug 5, 2026 | HPD C | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS AT REAR YARD | Closed |
| Aug 5, 2026 | HPD B | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF MATTRESS AT PUBLIC HALL, 4th STORY | Closed |
| Aug 5, 2026 | HPD B | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF TV AND HOUSEHOLD ITEMS AT PUBLIC HALL, 3rd STORY | Closed |
| Aug 5, 2026 | HPD C | 567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, G | Closed |
| Jun 29, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2W, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 23, 2026, 9:16 AM ET. BBL 3051220039.