5 floors · 40 apartments · 16,050 sq ft · built 1997 · class N9 · owner of record: Casa Esperanza Housing Devel. Fund Compa Ny, Inc.,
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 60 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 60 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 60 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 76 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Annual boiler inspection (3 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-02-04 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 2, 2026 | Elevators CLASS - 1 CLASS 1 C/U: IN-CAR STOP SWITCH INOPERATIVE, AS PER ASME A17.1 2.26.2.21. STOP SWITCH IS A REQUIRED EMERGENCY SAFETY DEVICE; ITS INOPERABILITY PREVENTS THE CAR FROM BEING STOPPED BY THE OPERATOR IN AN EMERGENCY #39206469Y | Dec 18, 2026 PENDING | $1,250 |
| Oct 16, 2025 | Elevators CLASS - 1 CLASS 1 CEASE USE ITEM: DOOR ZONE RESTRICTOR INOPERATIVE. THIS IS A SAFETY FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY: TO RESTORE SERVICE, EMAIL THE D.O.B. EIR@BUILDINGS.NYC.GOV. FOR A REINSPECTION. CLASS 2 #39163871P | May 1, 2026 IN VIOLATION | $1,250 |
| Aug 24, 2023 | Unknown CLASS - 1 I OBSERVED IN THE REAR YARD THE USE OF FLEXIBLE WIRING TO SUPPLY POWER FROM THE SPLIT UNIT A.C. CONDENSER TO THE INDOOR BLOWER UNITS. THE USE OF FLEXIBLE WIRING AS PERMANENT WIRING NOR PASSING THROUGH WALLS IS #39093992K | Nov 17, 2023 DEFAULT | $0 |
| Aug 24, 2023 | Unknown CLASS - 2 I OBSERVED ON THE ROOFTOP THE RACEWAY SUPPLYING POWER TO THE EXHAUST FAN NOT PROPERLY SUPPORTED OR SECURED AS REQUIRED. PHOTOS TAKEN, SECURE/SUPPORT PER EC #39093993M | Nov 17, 2023 DEFAULT | $0 |
| Aug 24, 2023 | Unknown CLASS - 1 I OBSERVED IN THE REAR COURTYARD THE INSTALLATION OF BRANCH CIRCUIT WIRING, RACEWAYS, DISCONNECT SWITCHES TO SUPPLY POWER FOR A SPLIT A.C. UNIT. NO PERMITS ON FILE IN DOB RECORDS, OBTAIN PERMIT; OBTAIN PERMIT C #39093991Z | Nov 17, 2023 DEFAULT | $0 |
| Apr 6, 2023 | Boilers CLASS - 2 AS PER ONE MODULAR SLANT/FIN HEATING BOILER. ONE MODULE IS LEAKING AND FLOODING UP BOILER ROOM FLOOR. #39083186R | Aug 4, 2023 IN VIOLATION | $0 |
| Jul 10, 2019 | Boilers CLASS - 2 FOUND BYPASS VALVE AT BACK FLOW PREVENTER, BACK FLOW PREVENTER SHALL NOT HAVE BYPASS VALVE. REMOVE ALL COMBUSTIBLE STORAGE FROM BOILER ROOM, BOILER ROOM TO BE FIRE RATED. #39005232P | Aug 30, 2019 STIPULATION/IN-VIO | $0 |
| Aug 15, 2018 | Boilers CLASS - 2 32A.50A.50B.50C.50D-AS PER CLASS(B254)28.301.1 FAILURE TO MAINTAIN.32A:EXPOSED ELECTRICAL WIRING.50A:SPILL SWITCH INSTALLED ON LAARS BOILER.50B:MANUAL RESET (AGUASTAT)NOT INSTALLED ON LAARS BOILER.50C:SAFETY RE #32097665R | Oct 5, 2018 STIPULATION/IN-VIO | $0 |
| Sep 27, 2017 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.OBSERVED NO VENTILATION IN THE GAS METER ROOM AND THE ALARM CHECK VALVE IN THE GAS METER ROOM LEAKING AT IT CONNECTION TO THE SYSTEM. REMEDY:REPAIR AND #35293712H | Nov 17, 2017 IN VIOLATION | $0 |
| Sep 27, 2017 | Construction CLASS - 3 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: @ STAIRCASE'B' THROUGHOUT, SEVERAL STEP CRACK & HORIZONTAL & VERTICAL CRACKS OBSERVED. REM: REPAIR &/OR REPLACE. #35293730L | Apr 13, 2018 IN VIOLATION | $0 |
| Dec 20, 2016 | Plumbing CLASS - 1 SEC. 408.2 MISC VIOLATION. OBSERVED ON 12/20/16 @ 10:45AM ON 1ST FL BOILER ROOM. FUTURE TEE & CAPS EXIST DOWN STREAM OF APPLIANCE VALVE AT EQUIPMENT. REMEDY: COMPLY W/NOTICE OF VIOLATION. #35208068R | May 12, 2017 IN VIOLATION | $0 |
| Dec 20, 2016 | Plumbing CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED ON 12-20-16 @10:45AM FAILURE TO PROVIDE A SYSTEM OF AUTOMATIC SPRINKLER @ FRONT DOOR ENCLOSED ENTRANCE-FILE AMRM PANEL LOCATION-AT CEILING. MISSING #35208070X | May 12, 2017 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Nov 29, 2023 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00030 | DOB VIOLATION - ACTIVE |
| Nov 22, 2023 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00162 | DOB VIOLATION - ACTIVE |
| Jun 25, 2015 | ELEVATOR #9027/ | DOB VIOLATION - ACTIVE |
| May 15, 2014 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT #08133 | DOB VIOLATION - ACTIVE |
| May 15, 2014 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT #08134 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 29, 2026 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Nov 29, 2023 | AEUHAZ FTC-AEU-HAZ | Active |
| Nov 22, 2023 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 2, 2023 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Report | Active |
| May 15, 2014 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT | Active |
| May 15, 2014 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Open |
| Oct 2, 2026 | ECB | Elevators: CLASS 1 C/U: IN-CAR STOP SWITCH INOPERATIVE, AS PER ASME A17.1 2.26.2.21. STOP SWITCH IS A REQUIRED EMERGENCY SAFETY DEVICE; ITS INOPERABILITY PREVENTS THE CAR FROM BEING STOPPED BY THE OPERATOR IN AN EMERGENCY | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 1, 2026, 4:49 PM ET. BBL 2029480016.