11 floors · 26,400 sq ft · built 1932 · class P3 · owner of record: Ymca Of Greater N Y
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 45 days | Keep the report on file (not filed with DOB) |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $75,000 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2027 in 97 days | No Cycle 10 report on record yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 26,400 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 166 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 166 days | Annual filing |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 10 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 776 days | Next cycle year 2028 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-03 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 23, 2026 | Construction CLASS - 2 NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 FAILURE-TO-MAINTAIN VIOLATION #39145007N ISSUED 4/15/2025 CITING HOLE PENETRATIONS THROUGHOUT THE BUILDING. AT INSPECTION, FIRESTOPPING HAD BEEN NEWLY INSTALLED #39197380X | Oct 1, 2026 IN VIOLATION | $1,250 |
| Jan 2, 2026 | Construction CLASS - 2 OBSERVED ON THE ROOF, SIX FLOOR AND BASEMENT LACK FIRESTOPPING AT PENETRATIONS THROUGH WALLS FOR PIPE LINES. ON THE 11 TH FLOOR STAIRCASE STANDPIPE CAP IS OBSTRUCTED BY ELECTRICAL LINE. ON FLOORS 11, 6,7,8,9 SP #39172209P | Mar 12, 2026 IN VIOLATION | $1,250 |
| Jan 2, 2026 | Construction CLASS - 2 OBSERVED ON THE 9TH AND 7TH FLOOR SINKS NOT OPERATIONAL. ON THE SIX FLOOR DRINKING FOUNTAIN DRAIN IS NOT INSTALLED PROPERLY. FIRST FLOOR BASEMENT USING PLASTIC CAPS ON STANDPIPE. FIRE PUMP ROOM INSTALLED PIPING #39172208N | Mar 12, 2026 IN VIOLATION | $1,250 |
| Dec 30, 2025 | Elevators CLASS - 1 CLASS 1 RTS: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE, CREATING A HAZARDOUS CONDITION #39171942N | Mar 5, 2026 IN VIOLATION | $1,250 |
| Dec 30, 2025 | Elevators CLASS - 1 CLASS 1 CEASE USE ITEM: DOOR ZONE RESTRICTOR INOPERATIVE. THIS IS A SAFETY FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY: TO RESTORE SERVICE, EMAIL THE D.O.B. EIR@BUILDINGS.NYC.GOV. FOR A REINSPECTION. CLASS 2 #39171943P | Mar 5, 2026 IN VIOLATION | $1,250 |
| Apr 15, 2025 | Elevators CLASS - 2 CLASS 2 ITEMS: CATEGORY 1 TEST TAG EXPIRED. CLEAN ENTIRE PIT AREA. #39144950J | Jun 26, 2025 IN VIOLATION | $0 |
| Apr 15, 2025 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE. OBSERVED HOLE PENETRATIONS THROUGHOUT THE BUILDING. POTENTIAL FIRE HAZARD., PROVI #39145007N | Jun 26, 2025 IN VIOLATION | $0 |
| Apr 14, 2025 | Boilers CLASS - 2 FOUND A ROCKMILL MP125 STEAM BOILER SLIGHT LEAK FROM INSIDE THE BOILER/FRESH AIR FAN PROVING SWICTH NOT WORKING PROPELY/ SAFETEY VALVE DRAINTERMINATION TIED TOGETHER AND WITH THREADS AT THE END/BODY DRAIN MISSI #39144783L | Jun 26, 2025 IN VIOLATION | $0 |
| Apr 14, 2025 | Boilers CLASS - 2 FOUND ON SITE A TEMPORARY OIL TANK OUTSIDE PERMIT #M00807169-LA NOT SIGNED OF. PERMIT FILLING UNDER PENALTY REVIEW., MAINTAIN BOILER; CORRECT ALL VIOLATING CONDITION/ SUBMIT CERIFICATE OF CORRECTION #39144799X | Jun 26, 2025 IN VIOLATION | $0 |
| Mar 21, 2025 | Elevators CLASS - 1 CEASE USE ITEM: DOOR ZONE RESTRICTOR INOPERATIVE. THIS IS A SAFETY FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY: TO RESTORE SERVICE, EMAIL THE D.O.B. EIR@BUILDINGS.NYC.GOV. FOR A REINSPECTION #39142483K | Nov 17, 2025 IN VIOLATION | $1,250 |
| Jan 16, 2024 | Plumbing CLASS - 2 AS PER PROVISION OF LAW 28-301.1. FAILURE TO MAINTAIN PLUMBING SYSTEM. FOUND LAVATORY WASTE ON 4TH FL. WOMEN'S ROOM LEAKING AND FAWCETT LOOSE AS PER P.C. 702.1 AND 602.3., REMOVE NON-COMPLYING MATERIAL OR EQUIP #39103528N | Feb 10, 2025 IN VIOLATION | $0 |
| Jan 5, 2023 | Unknown CLASS - 2 I OBSERVED IN VARIOUS RESTROOMS AND THE KITCHENS ON FLOORS 4 THROUGH 10 DEFECTIVE, MISWIRED, GFCI OUTLETS, ALSO NOTED IN THE KITCHEN THE OUTLET BOX DISCONNECTED AND UNSECURED., INSTALL GFC1 PROTECTION; PROPERLY #39077064H | Oct 12, 2023 IN VIOLATION | $0 |
| Jan 5, 2023 | Construction CLASS - 2 OBSERVED: AT EXPOSURE #1&4,EXIT DOORS, ROOF LEVEL EXIT DOOR AND ELEVATOR ROOM DOOR, DO NO SELF-CLOSING PROPERLY DUE OVERLAPPING DOOR LEAVES, OR SELF CLOSING SYSTEM., REPAIR/REPLACE DOOR #39077054Y | Sep 14, 2023 IN VIOLATION | $0 |
| Jan 5, 2023 | Unknown CLASS - 2 I OBSERVED IN THE BASEMENT AREA NEAR THE ELECTRICAL ROOM ROMEX WIRING PASSING THROUGH A WALL SUPPLYING POWER TO A FAN IN A STORAGE CLOSET, ALSO NOTED A DEFECTIVE FLEXIBLE CORD PASSING AROUND A DOORWAY,ALSO NOTE #39077063X | Oct 12, 2023 IN VIOLATION | $0 |
| Jan 5, 2023 | Unknown CLASS - 2 I OBSERVED IN THE CORRIDORS ON ALL FLOORS, FAILURE TO PROPERLY TERMINATE THE RACEWAYS SUPPLYING POWER TO THE CEILING LIGHTS AND EMERGENCY LIGHTING THE WIREMOLD RACEWAYS ARE NOT MECHANICALLY CONNECTED AS REQUIRE #39077062Y | Oct 12, 2023 IN VIOLATION | $0 |
| Jan 5, 2023 | Construction CLASS - 2 OBSERVED: AT ROOF LEVEL, ELEVATOR ROOM, VARIOUS OPENINGS DUE TO PENETRATION OF PIPES THROUGH WALLS, WALL DAMAGE WITHOUT FIRE STOPPING PROVIDED., PROVIDE/MAINTAIN FIRE STOPPING #39077052K | Sep 14, 2023 IN VIOLATION | $0 |
| Dec 9, 2022 | Local Law CLASS - 2 FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE 9A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL & APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #906681.REMEDY:SUBMIT ACCEPTABLE REQUIRED TE #37024982P | Apr 20, 2023 IN VIOLATION | $0 |
| May 25, 2022 | Construction CLASS - 2 AT 6TH/5TH FL, CORRIDORS AND STAIRCASE A&B WITHOUT EMERGENCY LIGHTS INTALLED. ALSO, AT 5TH FL STAIR B & 6TH FL FRONT ELEVATOR, EXISTING EMERGENCY LIGHTS WERE NOT OPERATIONAL WHEN TESTED, REPAIR/REPLACE LIGHTING #39062849X | Oct 27, 2022 IN VIOLATION | $0 |
| May 25, 2022 | Construction CLASS - 2 AT CELLAR LEVEL, UTILITY ROOM, VARIOUS OPENINGS DUE TO PENETRATION OF PIPES THROUGH CEILINGS AND WALLS WITHOUT FIRE STOPPING PROVIDED, PROVIDE/MAINTAIN FIRE STOPPING #39062846K | Oct 27, 2022 IN VIOLATION | $0 |
| May 25, 2022 | Construction CLASS - 2 AT 6TH/5TH FL, STAIRCASE B METAL STAIR WITH DETERIORATED AND BROKEN STEPS, REPAIR AND/OR REPLACE #39062848Y | Oct 27, 2022 IN VIOLATION | $0 |
| May 25, 2022 | Construction CLASS - 2 AT EXPOSURE #1&2,EXIT DOORS DO NO SELF-CLOSING PROPERLY DUE OVERLAPPING DOOR LEAVES, OR MISSING SELF CLOSING SYSTEM., REPAIR/REPLACE DOOR #39062847M | Oct 27, 2022 IN VIOLATION | $0 |
| Oct 28, 2021 | Construction CLASS - 2 I OBSERVED IN THE GAS METER ROOM LOCATED IN THE BASEMENT CRACKED AND ALSO BROKEN CAST IRON SANITARY PIPING AND FITTINGS., REPAIR AND/OR REPLACE #39050232H | May 5, 2022 ADMIT/IN-VIO | $0 |
| Jan 6, 2021 | Boilers CLASS - 2 PUMP LEAKING . CORRECT VIOLATING CONDITION & SUBMIT A CERTIFICATE OF CORRECTION. #39034391P | Jul 1, 2021 IN VIOLATION | $0 |
| May 31, 2018 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.AT ROOF IN WATERTOWER ROOM,BRICK COLUMN NEXT TO WATER TANK HAS LOOSE BRICKS,CRACKED BRICKS AND ENTIRE COLUMN DETACHED FROM WALL.REM:REPAIR AND/OR REPLACE CO #35332093R | Jan 11, 2019 IN VIOLATION | $0 |
| May 31, 2018 | Unknown CLASS - 2 ELECTRICAL WORK W/O A PERMIT. I OBSERVED IN THE MAIN ELECTRICAL ROOM IN THE BASEMENT THE INSTALLATION OF A FIRE PUMP SERVICE SWITCH AND ON THE 4TH AND 9TH FLOOR THE RETROFIT OF EXISTING ELECTRICAL PANELS WITH #35331850K | Sep 13, 2018 IN VIOLATION | $0 |
| May 31, 2018 | Unknown CLASS - 2 I OBSERVED IN THE WATER METER ROOM. THE GROUNDING ELECTRODE CONDUCTOR EXTREMELY DETERIORATED AT THE CONNECTION ON THE WATER PIPE. PHOTOS TAKEN. RMDY: PROVIDE PROPER CLEAN CONNECTION ON THE WATER PIPE AS PER #35331851M | Sep 13, 2018 IN VIOLATION | $0 |
| May 31, 2018 | Unknown CLASS - 2 I OBSERVED ON THE ROOF AT STAIR BA AND INSIDE THE 5TH AND 6TH FLOOR JANITORIAL CLOSETS; RACEWAYS NOT SUPPORTED AND SUBJECTED TO DAMAGE. PHOTOS TAKEN. RMDY: PROVIDE PROPER SUPPORT OF RACEWAYS. #35331852Y | Sep 13, 2018 IN VIOLATION | $0 |
| May 31, 2018 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED ON 5/31/18AT ABOVE ADDRESS. NO ADEQUATE VENTILATION IN GAS METER ROOM. RMDY: REPAIR AND OR REPLACE. #35334110Z | Jan 11, 2019 IN VIOLATION | $0 |
| Aug 18, 2017 | Construction CLASS - 3 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O OR BLDG DEPT RECORDS.C OF O #77527 INDICATES 5TH-9TH STORIES TO BE 35 BEDROOMS;WASH ROOM;TOILETS & SHOWER ROOMS. NOTED: ON 5TH FL ROOM 505 IS OCCUPIED AS OFFICE #35289914Y | Mar 8, 2018 ADMIT/IN-VIO | $0 |
| Apr 5, 2016 | Construction CLASS - 3 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDING DEPT RECORDS CERTIFICATE OF OCCUPANCY #M77527 INDICATES 5TH THROUGH 9TH FLRS TO BE 35 BEDROOMS; WASHROOMS, TOILET AND SHOWER ROOM #35177625L | Oct 13, 2016 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Feb 22, 2022 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022 #00654 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Report | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Aug 29, 2025 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Report | Active |
| Aug 29, 2025 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Report | Active |
| Oct 11, 2024 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Sep 11, 2024 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Report | Active |
| Sep 11, 2024 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Report | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction | Active |
| Oct 2, 2023 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction | Active |
| Oct 2, 2023 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction | Active |
| Aug 25, 2023 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Report | Active |
| Feb 22, 2022 | Facades FISPNRF FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Apr 4, 2024 | C | Apt 418 · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTIRE APARTMENT LOCATED AT APT 418, 4th STORY, 5th APARTMENT FROM EAST AT SOUTH | Apr 18, 2024 |
| Feb 1, 2024 | C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES AT COMMUNITY BATHROOM, 4th STORY | Feb 27, 2024 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Report | Open |
| Jul 23, 2026 | ECB | Construction: NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 FAILURE-TO-MAINTAIN VIOLATION #39145007N ISSUED 4/15/2025 CITING HOLE PENETRATIONS THROUGHOUT THE BUILDING. AT INSPECTION, FIRESTOPPING HAD BEEN NEWLY INSTALLED | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 16, 2026, 7:35 AM ET. BBL 1019190053.