4 floors · 10,000 sq ft · built 1931 · class K4 · owner of record: Linda Properties Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 61 days | Keep the report on file (not filed with DOB) |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 792 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 19, 2018 | Construction CLASS - 2 WORK W/O A PERMIT. AT FRONT 4 STORIES FACADE FACING GRAHAM AVE, AN ILLUMINATED LETTERS BUSINESS ACCESSORY SIGNS APPROX 22'X3' READ "HYPERACTIVE" AND BETWEEN 3RD+4TH FLOOR LEVEL APPROX 15'X10 READ "AYP" W/ ELLIP #35369888J | Jan 7, 2019 DEFAULT | $6,250 |
| May 30, 2009 | Construction CLASS - 1 SEC. 28-201.1 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO OBTAIN A PERMIT PER VIOLATION #34612076P. INSTALLATION OF STRUCTURAL STEEL MEMBERS & WOOD CEILING JOISTS THROUGHOUT THE CELLAR W/O PERMIT. NO REC #34791138H | Nov 12, 2009 WRITTEN OFF | $0 |
| Oct 18, 2008 | Construction CLASS - 1 SEC. 28-201.1 FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER'S TOFILE FOR A PERMIT VIS NOV #34612076P. INSTALLATION OF STRUCTURAL STEELMEMBERS & WOOD CEILING JOISTS THROUGHOUT THE CELLAR W/O A PERMIT. #34712482Z | Jun 25, 2009 WRITTEN OFF | $0 |
| Apr 15, 2008 | Unknown Hazardous FAILURE TO COMPLY W/AN ORDER OF THE COMMISSIONER TO CORRECT THE CONDITION CITED IN NOV #34612076P. INSTALED NEW WOOD CEILING JOISTS & STRUCTURAL STEEL MEMBERS THROUGHOUT THE CELLAR LEVEL W/O A PERMIT. NO RECORD #34646614Z | Mar 12, 2009 IN VIOLATION | $0 |
| Nov 8, 2007 | Construction Hazardous WORK W/O A PERMIT NOTED:INSTALLATION OF NEW WOOD CEILING JOISTS APPROX100'L X 25'W X 12"D WITH NEW STRUCT.STEEL MEMBERS IN PLACE THRU-OUT CELLAR LEVEL OF COMMERICAL BLDG WITH NO PERMIT FOR WORK DONE ON FILE W/ #34612076P | Dec 31, 2007 DEFAULT | $0 |
| Nov 8, 2007 | Construction Hazardous FAILURE TO MAINTAIN BLDG DEFECTS NOTED: 1)4TH FL WOOD FL JOISTS ARE ROTTEN,SAGGING,& DEFLECTING APPROX.6" AT FRONT OF BLDG 2)4TH FL HAS SEVERAL HOLES APPROX.2'L X 2'W IN VARIOUS LOCATIONS IN WOOD FL 3)LARGE ACC #34612949P | Jan 15, 2009 IN VIOLATION | $0 |
| Nov 8, 2007 | Construction Non-Hazardous FAILURE TO PROTECT FIRE STOPPING WHERE REQUIRED DEFECTS NOTED: CELLAR OF COMMERICAL BLDG BEING USED AS STORAGE WITH EXPOSED WOOD CEILING JOISTS & NO FIRE STOPPING (RATED) OR SPRINKLER SYSTEM INSTALLED AT CELLAR #34612075N | Jul 3, 2008 IN VIOLATION | $0 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Jan 8, 2026 | Gas Piping - LL152 FTF-PL-PER Cycle 2, Sub-cycle A (premises is in Community District 1) | Active |
None open.