1 floors · 6,900 sq ft · built 2006 · class K1 · owner of record: Tarik Equity Corp.
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 63 days | Keep the report on file (not filed with DOB) |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 14 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 428 days | Next cycle year 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 18, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION, I OBSERVED AT PREMISES THE UNDERSIDE OF THE SIDEWALK SHEDS IN PLACE AT EXP#1, NOT ILLUMINATED BY ELECTRIC LIGHT BC 3307.6.4.8 LIGHTING. THIS CAUSES DANGEROUS CONDITIONS AFTER DAYLIGHT HOU #39558049R | Oct 27, 2026 PENDING | $2,400 |
| Aug 14, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION, I OBSERVED A SIDEWALK SHED IN PLACE AT EXPOSURE#1, MISSING CAPS FROM THE BOLTS. THIS CREATES SHARP EDGES. CAUSING HAZARDOUS CONDITIONS FOR PEDESTRIANS AS PER BC 3307.6.5.6 SHARP EDGES. #39558006R | Oct 27, 2026 PENDING | $2,400 |
| Feb 25, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLAINT MANNER. OBSERVED AT EXP #1 MISSING PARAPET SECTION 7' BY 5'., REPAIR AND/REPLACE #39178276M | Jun 23, 2026 DEFAULT | $25,000 |
| Jan 9, 2024 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER. NOTE A SECTION OF BRICK PARAPET WALL AND LIGHT METAL FRAMED AWNING FELL ONTO THE SIDE WALK. PARAPET SECTION 25'X 5'X 10. OTHER SECTION DEFECTIVE. ADDRESS 1 #39103155J | Jul 17, 2025 DEFAULT | $25,000 |
| Issued | Violation | Status |
|---|---|---|
| Mar 20, 2024 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00111 | DOB VIOLATION - ACTIVE |
| Jan 11, 2024 | IMMEDIATE EMERGENCY REMEDY: ERECT APPROX' 45 LINEAR FEET OF SIDEWALK SHED EXPOSURE 1 EXTEN DING TO 1815 & 1817 MOTT AVE PROPERTIES TO SAFEGUARD THE PUBLIC AND PR OPERTY #18078 | DOB VIOLATION - ACTIVE |
| Jan 11, 2024 | IMMEDIATE EMERGENCY REMEDY: ERECT APPROX 45 LINEAR FEET OF SIDEWALK SHED AT EXPOSURE 1 EXT ENDING TO 1817 & 1813 MOTT AVE PROPERTIES TO SAEFGUARD THE PUBLIC AND PROPERTY #18079 | DOB VIOLATION - ACTIVE |
| Jan 11, 2024 | IMMEDIATE EMERGENCY REMEDY: ERECT APPROX 45 LINEAR FEET OF SIDEWALK SHED AT EXPOSURE 1 EXT ESNDING TO 1815 & 1813 MOTT AVE PROPERTIES TO SAFEGUARD THE PUBLIC AND PROPERTY #18080 | DOB VIOLATION - ACTIVE |
| Jan 11, 2024 | IMMEDIATE EMERGENCY REMEDY ERECT APPROX 75 LINEAR FEET OF SIDEWALK SHED AND COSNTRUCT FENC E AT EXPO 1 STARTING FROM 1813 MOTT AVE TO 1819 MOTT AVE PROPERTIES TO SAFEGUARD THE PUBLIC AND PROEPRTY ALSO REMOVE ALL DEBRIS #18082 | DOB VIOLATION - ACTIVE |
| Jan 9, 2024 | CONSTRUCTION A SECTION OF THE BRICK PARAPET AND STRUCTURAL STEEL I BEAM AND AWNING FELL TO THE SIDEWALK. OTHER SECTIONS OF THE PARAPET IS DEFECTIVE. #24-00062 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jul 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Jan 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle D (premises is in Community District 14) | Active |
| Mar 20, 2024 | AEUHAZ FTC-AEU-HAZ | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Aug 18, 2026 | ECB | Construction: AT TIME OF INSPECTION, I OBSERVED AT PREMISES THE UNDERSIDE OF THE SIDEWALK SHEDS IN PLACE AT EXP#1, NOT ILLUMINATED BY ELECTRIC LIGHT BC 3307.6.4.8 LIGHTING. THIS CAUSES DANGEROUS CONDITIONS AFTER DAYLIGHT HOU | Open |
| Aug 14, 2026 | ECB | Construction: AT TIME OF INSPECTION, I OBSERVED A SIDEWALK SHED IN PLACE AT EXPOSURE#1, MISSING CAPS FROM THE BOLTS. THIS CREATES SHARP EDGES. CAUSING HAZARDOUS CONDITIONS FOR PEDESTRIANS AS PER BC 3307.6.5.6 SHARP EDGES. | Open |
| Jul 30, 2026 | DOB Safety | AEUHAZ: | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 29, 2026, 2:51 PM ET. BBL 4155600034.