Brooklyn · Block 1709 · Lot 36 · 11233

1797 Atlantic Avenue

2 floors · 4,740 sq ft · built 1921 · class E1 · owner of record: 1795 Atlantic Ave Llc

2open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
793dto Gas piping inspection (2028 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 62 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 793 days
Next cycle year 2028

Open violations

ECB / OATH (1)
IssuedViolationHearingBalance
Nov 24, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. AS NOTED AT TIME OF INSPECTION, OBSERVED A 2 STORY BUILDING. AT CELLAR LEVEL AND 1ST FLOOR, OBSERVED SUBSTANTIAL CRACKING AND DAMAGE TO CONCRETE SLAB WIT
#35717873P
Aug 18, 2026
IN VIOLATION
$0
DOB (1)
IssuedViolationStatus
Nov 24, 2025CONSTRUCTION
EWO.2STORY BLDG EXHIBIT SUBSTANTL DEFECTS IN CONCRTE SLABS & MASONRY WALLS.REMDY:INSTALL ADEQATE SAFETY/STABILITY MEAS.IMMEDITE RETAIN ANY S P.E TO EVALUTE ENTIRE STRUCTRE & PROVIDE A STABILTY REPORT WITH METH -OD OF STABILIZIN/REPAIRIN THESTRUCTRE P.E TO SUPERV THE IMMEDIATEIN STALLTN OF STABILITY/
#PS30301JL
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Sep 23, 2026DOB SafetyParking Structures: Failure to file parking structures compliance report by 12/31/2025 as required per 1 RCNY 103-13Closed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 30, 2026, 8:53 AM ET. BBL 3017090036.

Look up another building