Bronx · Block 2948 · Lot 29 · 10457

1794 Clinton Avenue

6.5 floors · 57 apartments · 40,288 sq ft · built 2025 · class C1 · owner of record: 1794 Clinton Llc

5open violations
$41,110ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 56 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 56 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 56 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 72 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 40,288 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 177 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 177 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueNo current registration found
Facade inspection report (Cycle 10B) Applies
Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. Agency page

Feb 21, 2028
in 473 days
No Cycle 10 report on record yet

Open violations

ECB / OATH (14) · $41,110 owed
IssuedViolationHearingBalance
Sep 23, 2026Construction CLASS - 2
PROPOSED 9 STORY BUILDING ACTIVE SITE. SIDEWALK SHED IN PLACE AT EXP#1 PERMIT#X01125090, CONTRARY TO PLANS/CODE. OBSERVED MUDSILLS/VERTICAL MEMBERS AT BASE LEVEL COVERED WITH CONCRETE/DEBRIS DIRT/OTHER MATERIAL
#39559536Z
Dec 4, 2026
PENDING
$1,250
Sep 23, 2026Construction CLASS - 2
PROPOSED 9 STORY NB ACTIVE SITE BELOW 75 FT. WORK CONTRARY TO APPROVED SITE SAFETY PLANS (SSP). PLANS SHOW ROOF PROTECTION OF ADJOINING PROPERTY/NO ROOF PROTECTION IN PLACE AT EXP#4 3309.10. NEEDLE BEAMS MISSIN
#39559534P
Dec 4, 2026
PENDING
$1,250
Sep 23, 2026Construction CLASS - 2
PROPOSED 9 BUILDING ACTIVE SITE. SUPPORTED SCAFFOLD INSTALLED IN PLACE PERMIT#X01458961. CONTRARY TO PLANS PLANS SHOW 3 FT MASONRY FRAMES AT BASE LEVEL AT CELLAR LEVEL. 6 FT WALK THRU FRAMES INSTALLED. NO DETAI
#39559535R
Dec 4, 2026
PENDING
$1,250
Jul 8, 2026Construction CLASS - 2
GENERAL CONTRACTOR FAILED TO FILE CERTIFICATE OF CORRECTION WITH THE DOB. NO CORRECTIVE MEASURES ON RECORD FOR VIOLATION# 039554046N. FILE CERTIFICATE OF CORRECTION...
#39556359N
Sep 18, 2026
DEFAULT
$1,280
May 12, 2026Construction CLASS - 2
OBSERVED STORAGE ZONE AT STREET LEVEL OF JOBSITE. THE STORAGE ZONE HAS HEAVY MACHINERY W/OUT ADEQUATE PREVENTIVE MEASURES IN PLACE TO PREVENT GENERAL PUBLIC FROM GAINING ACCESS/ BEING EXPOSED TO SAID EQUIPMENT.
#39554058K
Jan 22, 2027
$2,400
May 12, 2026Unknown CLASS - 1
3310.4-MAJOR BUILDING UNDER PERMIT # X01194388 CURRENTLY AT THE 6TH STORY LEVEL, PLANS SUBMITTED FOR 10 STORIES BUILDING W/OUT APPROVED SITE SAFETY PLAN BY THE DEPARTMENT. REFERENCE PAGE 10 - Z001-01, 23 - A-30
#39554046N
Jan 22, 2027
$5,000
May 12, 2026Unknown CLASS - 1
3310.5 SITE SAFETY MANAGER OR COORDINATOR TO BE DESIGNATED-MAJOR BUILDING UNDER PERMIT # X01194388 CURRENTLY AT THE 6THB STORY LEVEL, PLANS SUBMITTED FOR 10 STORIES BUILDING W/OUT DESIGNATION OF SITE SAFETY MAN
#39554047P
Jan 22, 2027
$5,000
May 12, 2026Construction CLASS - 2
OBSERVED C-JOIST INSTALLED THROUGHOUT ENTIRE JOBSITE. ON EACH FLOOR STRAPS AND BLOCKING ARE INSTALLED IN CONTINUOUS AREAS COVERING FULL SPAN OF FLOOR FRAME. REVIEW OF DETAILS IN PROVIDED APPROVED PLANS SHOWS BL
#39554057Z
Jan 22, 2027
$1,250
Jan 31, 2026Construction CLASS - 2
DURING MY INSPECTION. I OBSERVED A LULL EQUIPMENT PARK AT THE WORK AND STORAGE ZONE ALONG THE SIDEWALK SHED WITH NO PEDESTRIAN PROTECTION IN PLACE, NO 4' HIGH PLYWOOD WITH WIRE MESH UNDERSIDE OF THE SIDEWALK SH
#39549737X
Sep 11, 2026
IN VIOLATION
$2,400
Jan 31, 2026Unknown CLASS - 2
6-STORY NB AT THE SECOND FLOOR. ONE VIOLATION SERVED FOR NO COMPETENT WATCHPERSON ON DUTY AT THE SITE DURING ALL HOURS WHEN OPERATIONS ARE NOT IN PROGRESS. BUILDING, FOOTPRINT 6,470 SQFT. UPON WALKING THE PERIM
#39549723P
Sep 11, 2026
IN VIOLATION
$2,500
Jan 31, 2026Construction CLASS - 1
DURING MY INSPECTION OF A CLOSED 6-STORY NB. I OBSERVED TIMBER BARRIERS AT EXPOSURE 1 WORK AND STORAGE ZONE, REVIEWING THE POST DOT PERMITS, WHICH CALL FOR JERSEY BARRIERS, NOT TIMBER BARRIERS. STOP ALL OPERATI
#39549738H
Sep 11, 2026
IN VIOLATION
$2,500
Nov 11, 2025Construction CLASS - 2
OBSERVED AT EXPO#4 ADJACENT BUILDING HAS CRACKS AND CONCRETE DAMAGE FROM THE CONSTRUCTION OPERATIONS TAKING PLACE AT 1794 CLINTON AVE. CREATING UNSAFE STRUCTURAL CONDITIONS TO THE NEIGHBORING PROPERTY. UPON CHE
#39546857R
Dec 14, 2026
DEFAULT
$5,030
Oct 28, 2025Construction CLASS - 2
FAILURE TO SAFEGUARD - DUE TO ATOI OBSERVED SECTION OF THE LEFT SIDE REAR ADJACENT PROPERTY(1802 CLINTON AVE.) REAR YARD SLAB WAS DAMAGE & DIRT IS CAVING INTO SITE. THIS PARTIAL DAMAGE WAS CAUSE DURING ACTIVE O
#39165152H
Jan 2, 2026
DEFAULT
$5,000
Oct 28, 2025Construction CLASS - 2
WORK NOT CONFORM TO APPROVED PLANS PROVIDED ON JOB SITE UNDER PERMIT(S) # X01194388-S2-FO & X01194388-S1-SE, DUE TO AT TIME OF INSPECTION OBSERVED 10 NEW SOLDIER PILES INSTALLED AT FRONT AREA OF SITE & IS NOT I
#39165134Y
Jan 2, 2026
DEFAULT
$5,000
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Sep 23, 2026ECBConstruction: PROPOSED 9 STORY BUILDING ACTIVE SITE. SIDEWALK SHED IN PLACE AT EXP#1 PERMIT#X01125090, CONTRARY TO PLANS/CODE. OBSERVED MUDSILLS/VERTICAL MEMBERS AT BASE LEVEL COVERED WITH CONCRETE/DEBRIS DIRT/OTHER MATERIALOpen
Sep 23, 2026ECBConstruction: PROPOSED 9 STORY NB ACTIVE SITE BELOW 75 FT. WORK CONTRARY TO APPROVED SITE SAFETY PLANS (SSP). PLANS SHOW ROOF PROTECTION OF ADJOINING PROPERTY/NO ROOF PROTECTION IN PLACE AT EXP#4 3309.10. NEEDLE BEAMS MISSINOpen
Sep 23, 2026ECBConstruction: PROPOSED 9 BUILDING ACTIVE SITE. SUPPORTED SCAFFOLD INSTALLED IN PLACE PERMIT#X01458961. CONTRARY TO PLANS PLANS SHOW 3 FT MASONRY FRAMES AT BASE LEVEL AT CELLAR LEVEL. 6 FT WALK THRU FRAMES INSTALLED. NO DETAIOpen

Check the agency records