3 floors · 99,000 sq ft · built 1927 · class W1 · owner of record: Nyc Department Of Education
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Annual boiler inspection (3 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-12-15 (Accepted). Agency page | Dec 31, 2026 in 47 days | 3 of 3 without an accepted 2026 report yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 99,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 168 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 168 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 412 days | Next cycle year 2027 |
| Energy audit and retro-commissioning (2033) Likely applies Local Law 87 · Calendar year 2033 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 12993). Agency page | Dec 31, 2033 in 2604 days | Next due 2033 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jun 3, 2026 | Construction CLASS - 2 REISSUE ON ECB#35725564L FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:WIRE MESH GLASS PANELS IN STAIRWELLS CRACKED/BROKEN IN STAIR C 1ST FLOOR STAIR C AND D FROM 3RD TO 2ND FLOOR,STAIR D FROM 3RD #35732088P | Jul 15, 2026 POP/IN-VIO | $0 |
| Jun 3, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:AT ROOF LEVEL ON BULKHEAD STAIR C,VERTICAL AND STEP CRACKS AROUND PERIMETER OF BULKHEAD,INCLUDING AN APPROX 3 FT-4 FT VERTICAL CRACK ON HVAC AIR INTAK #35732093J | Jul 15, 2026 POP/IN-VIO | $0 |
| Jun 3, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1.8;27-371(J).NOTED:ILLEGAL INSTALLATION OF KICK STOP DOOR STOPS ON FIRE RATED CLASSROOMS,255,209,211,319 #35732091X | Jul 15, 2026 POP/IN-VIO | $0 |
| Jun 3, 2026 | Construction CLASS - 2 EXIT DOOR NOT SELF-CLOSING.NOTED:EMERGENCY EXTERIOR EXIT DOORS NOT SELF-CLOSING DUE TO BINDING,MISSING AND OR FAULTY HARDWIRE ON EXTERIOR EXIT DOOR AT EXIT#8 1ST FL 2 DOORS EXIT#7 1ST FLOOR 1 DOOR AND EXIT#6 1S #35732090Y | Jul 15, 2026 POP/IN-VIO | $0 |
| Jun 3, 2026 | Construction CLASS - 2 REISSUE ON ECB#35725563J FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:FIRE RATED CLASSROOM AND SMOKE DOORS NOT SELF-CLOSING DUE TO BINDING,MISSING AND OR FAULTY HARDWIRE ON CLASSROOMS 319,361,313 #35732089R | Jul 15, 2026 POP/IN-VIO | $0 |
| Jun 3, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.ILLUMINATION FOREXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-381.NOTED:EMERGENCY ILLUMINATED EXIT DISCHARGE LIGHTS AND EXIT SIGNS NOT WORKING #35732092H | Jul 15, 2026 POP/IN-VIO | $0 |
| Sep 29, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: STAIRWAY C HAS CRACKED GLASS AT STAIRWAY. REMEDY: COMPLY WITH CODE. #35725564L | Oct 24, 2025 POP/IN-VIO | $0 |
| Sep 29, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: 3RD FLOOR CORRIDOR/EXIT TO STAIRS DOORS AT A3 BY RM 359 CLOSER IS MISSING AND DOORS NOT CLOSING PROPERLY. ALSO STAIRWAY G. REMEDY: COMPLY WITH CODE. #35725563J | Oct 24, 2025 POP/IN-VIO | $0 |
| Aug 16, 2023 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC1006;1;27-381. AT 3FL #20, GYM, 2FL. BY STAIR A, 1FL BY ROOM 117, BY EXIT 2, 6, 7, 8, 9 #35677145N | Nov 3, 2023 DEFAULT | $1,562 |
| Aug 16, 2023 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT GROUND FLOORKITCHEN EXIT RAILING BROKEN OFF IN DISREPAIR EXIT 5 BROKEN STEP, EXIT 10 ELEVATED STEP CAUSING TRIP HAZARD. REMEDY: REPAIR AND/OR REPLACE. #35677146P | Nov 3, 2023 DEFAULT | $3,125 |
| Aug 16, 2023 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT 3 FLOOR BYR OOM 359, AND CORRIDOR, 1 FLOOR 14, 15, 107 DOORS AND HITTING FRAME NOTCLOSING PROPERLY. REMEDY: REPAIR AND/OR REPLACE. #35677148Z | Nov 3, 2023 DEFAULT | $3,125 |
| Aug 16, 2023 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT STAIR C BULKHEAD SPALLING AND CRACKS IN BRICKS, 2ND FLOOR ROOF PARAPET FLASHING FROM COUPING ON 137 AVENUE. REMEDY: REPAIR AND/OR REPLACE. #35677149K | Nov 3, 2023 DEFAULT | $3,125 |
| Aug 16, 2023 | Construction CLASS - 2 EXIT DOOR NOT SELF-CLOSING. EXIT DOORS 8, 7, 4, 6 RUBBING ON FRAME NOTWORK PROPERLY. REMEDY: REPAIR/REPLACE DOOR. #35677147R | Nov 3, 2023 DEFAULT | $3,125 |
| Aug 8, 2017 | Elevators CLASS - 1 97X10/97-X-10;REPAIR AND RESTORE CAR TO SERVICE. #38256782J | Nov 14, 2017 POP/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Nov 1, 2019 | ELEVATOR #9027/662034 | DOB VIOLATION - ACTIVE |
| Sep 18, 2017 | ELEVATOR #9027/612091 | DOB VIOLATION - ACTIVE |
| Oct 14, 2016 | ELEVATOR #9027/587274 | DOB VIOLATION - ACTIVE |
| Nov 4, 2013 | ELEVATOR #9027/486523 | DOB VIOLATION - ACTIVE |
| Oct 22, 2012 | ELEVATOR #9027/454450 | DOB VIOLATION - ACTIVE |
| Oct 28, 2011 | ELEVATOR #9027/400746 | DOB VIOLATION - ACTIVE |
| Oct 3, 2008 | ELEVATOR #9444/277360 | DOB VIOLATION - ACTIVE |
| Jan 13, 1997 | LOCAL LAW 10/81 - ELEVATOR #04121 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 2, 2026 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 14, 2026, 12:03 PM ET. BBL 4129930118.