Manhattan · Block 1029 · Lot 53 · 10019

1784 Broadway

20 floors · 206,334 sq ft · built 1912 · class O4 · owner of record: 1790 Broadway Assoc. Llc

9open violations
$2,500ECB/OATH penalties owed
0HPD class C (immediately hazardous)
69dto Annual boiler inspection (2 boilers)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 69 days
Keep the report on file (not filed with DOB)
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-11-21 (Accepted). Agency page

Dec 31, 2026
in 69 days
2 of 2 without an accepted 2026 report yet
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $1,722,600 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2027
in 121 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 206,334 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 190 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 190 days
Annual filing
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1165 days
Next cycle year 2029
Energy audit and retro-commissioning (2029) Likely applies
Local Law 87 · Calendar year 2029
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1029). Agency page

Dec 31, 2029
in 1165 days
Next due 2029

Open violations

ECB / OATH (3) · $2,500 owed
IssuedViolationHearingBalance
Sep 29, 2026Unknown CLASS - 2
BC3314.8 DEBRIS NETTING, AT THE TIME OF INSPECTION OF A 14-STORY MIXED-USE BUILDING AT EXP. NOS. 1 & 2 WAS OBSERVED TORN AT ALL THREE CORNERS AND EXTENDING OUTSIDE THE SCAFFOLD FRAME, CREATING AN UNSAFE CONDI
#39559913P
Dec 3, 2026
PENDING
$2,500
Apr 20, 2026Local Law CLASS - 2
FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8A AND 9A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #903226. AGG1: PRIOR NOV 37026172M UNDER
#37036478Y
Jul 16, 2026
IN VIOLATION
$0
Jan 16, 2024Local Law CLASS - 2
FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8A AND 9A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL#903226.AGG1:PRIOR NOV 37022144R UNDER 28
#37026172M
Apr 11, 2024
IN VIOLATION
$0
DOB (4)
IssuedViolationStatus
Mar 6, 2026CONSTRUCTION
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. OBSERVED DEFECTED CONDITIONS AS FOLLOWS: EXPOSURE 3 MISSING BRICKS. ROOF AREA: CRACK AT CHIMNEY AND FIRE PLACE VENT. REMEDY: REPAIR AND/OR REPLACE
#SR0501NS
DOB VIOLATION - ACTIVE
Apr 25, 2023HAZARDOUS CONDITION (FACADE)
CYCLE 9A UNSAFE REPORT FILED
#911049
DOB VIOLATION - ACTIVE
Oct 22, 2020ELEVATOR

#9027/682112
DOB VIOLATION - ACTIVE
Jul 31, 2018FACADE SAFETY PROGRAM

#HAZ87547
DOB VIOLATION - ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Apr 25, 2023Facades FISPHAZ
CYCLE 9A UNSAFE REPORT FILED
Active
Jul 31, 2018Facades FISP
CYCLE 8A UNSAFE REPORT FILED
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Sep 29, 2026ECBUnknown: BC3314.8 DEBRIS NETTING, AT THE TIME OF INSPECTION OF A 14-STORY MIXED-USE BUILDING AT EXP. NOS. 1 & 2 WAS OBSERVED TORN AT ALL THREE CORNERS AND EXTENDING OUTSIDE THE SCAFFOLD FRAME, CREATING AN UNSAFE CONDIOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 23, 2026, 1:55 AM ET. BBL 1010290053.