| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 51 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 51 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 51 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 67 days | Annual |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 9, 2025 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES; NOTED: OBSERVED CRACKS ALONG THE FRONT EXTERIOR FACADE BRICK WALL., MAINTAIN EXTERIOR BUILDING WALL #39153214X | Sep 24, 2025 DEFAULT | $25,000 |
| Jul 26, 2024 | Construction CLASS - 2 NOTED AT 1ST FLOOR, (2) WORKERS PLASTERING CEILINGS OF THE OPEN SPACE LAYOUT. CONTRARY TO PLANS FOR JOB#B00888838, WHICH INDICATE INTERIOR PARTITIONS FOR 10 ROOMS/OFFICES. REMOVED APPROX.90% OF PARTITIONS ALONG #39119971Y | Mar 24, 2025 IN VIOLATION | $625 |
| Jul 26, 2024 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED AT EXP#3 REAR FACADE IN DISREPAIR WITH STEP CRACKS THROUGHOUT SEVERAL LOCATIONS AND MISSING/WASHED OUT MORTAR JOINTS AT PARAPET WALL LEVEL. PAST ECB# #39119972X | Sep 22, 2025 IN VIOLATION | $1,563 |
| May 17, 2024 | Construction CLASS - 1 WORK WITHOUT A PERMIT. NOTED AT CELLAR LEVEL, PLUMBING WORK IN PROGRESS WITH INSTALLATION OF (3) RHEEM HOT WATER HEATER, WITH RED & BLUE PEX PIPING. ADDITIONALLY ELECTRICAL WORK FOR NEW MAIN BREAKER PANEL & (4) #39114678M | Jun 23, 2025 IN VIOLATION | $2,500 |
| May 17, 2024 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED AT EXP#3 REAR FACADE, STEP CRACKS THROUGHOUT SEVERAL LOCATIONS AND MISSING/WASHED OUT MORTAR JOINTS AT PARAPET WALL LEVEL., REPAIR AND/OR REPLACE #39114677K | Jun 23, 2025 IN VIOLATION | $625 |
| May 17, 2024 | Construction CLASS - 2 NOTED AT 1ST FLOOR LEVEL, EXIT SIGNS & EMERGENCY LIGHTS NOT OPERATIVE WHEN TESTED THROUGHOUT SEVERAL AREAS. POSES EVACUATION HAZARD IN THE EVENT OF AN EMERGENCY., REPAIR/REPLACE LIGHTING #39114676Z | Jun 23, 2025 IN VIOLATION | $625 |
| May 1, 2019 | Construction CLASS - 2 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O OR BUILDING DEPT RECORDS. NOTE:C OF O#149623 INDICATES 1ST FL TO BE OCCUPIED W/ A MEDICAL CENTER HOWEVER AT INSPECTION OBSERVED 1ST FL BEING USED AS A "TRANSITIO #35381145K | Aug 12, 2019 DEFAULT | $6,250 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Oct 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle C (premises is in Community District 9) | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Oct 23, 2023 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PLASTER WITH FIRE RATED MATERIAL AT THE CEILING AT PUBLIC HALL, 3rd STORY | Nov 27, 2023 |
| Oct 23, 2023 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AT PUBLIC HALL, 3rd STORY | Jan 26, 2024 |
| Oct 23, 2023 | C | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING VESTIBULE DOOR AT PUBLIC HALL, 1st STORY | Oct 29, 2023 |
| Aug 22, 2023 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDAND MATERIAL AT CEILING AT BULKHEAD AT PUBLIC HALL, 3rd STORY | Sep 26, 2023 |
| Aug 22, 2023 | A | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME MISSING , 1st STORY | Nov 25, 2023 |
| Aug 22, 2023 | A | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING., 1st STORY | Nov 25, 2023 |
| Aug 22, 2023 | C | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING METAL SCREEN BELOW SKYLIGHT AT BULKHEAD AT PUBLIC HALL, 3rd STORY | Aug 28, 2023 |
| Sep 14, 2022 | C | Apt 1 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Sep 20, 2022 |
| Aug 25, 2022 | C | Apt 1FL · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD SUB-FLOORING IN THE PRIVATE HALLWAY LOCATED AT APT 1FL, 1st STORY | Aug 31, 2022 |
| Aug 25, 2022 | B | § 27-2040 ADM CODE INSTALL AND MAINTAIN SUFFICIENT LIGHT OR LIGHTS OF AT LEAST 100 WATTS INCANDESCENT OR EQUIVALENT EACH, TO LIGHT ADEQUATELY FROM SUNSET TO SUNRISE THE REAR YARD | Sep 29, 2022 |
| Jun 23, 2022 | A | §27-2153 ADM CODE POST AND MAINTAIN A NOTICE, WRITTEN IN ENGLISH AND IN SPANISH, ON THE BUILDING ENTRANCE DOOR OR OTHER CONSPICUOUS LOCATION IN THE BUILDING COMMON AREA, STATING THAT: (1) THE BUILDING IS IN THE ALTERNATIVE ENFORCEMENT PROGRAM, (2) THAT OCCUPANTS MAY CALL 311 OR THE AEP AT 212-863-82 | Sep 26, 2022 |
| Jan 21, 2022 | A | Apt 1 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT SOUTH AND WEST WALLS IN THE 1st BATHROOM FROM EAST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Apr 26, 2022 |
| Jan 21, 2022 | B | Apt 1 · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE BASE CABINET AT WASH BASIN TO THE EAST WALL IN THE 3rd BATHROOM FROM EAST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Feb 25, 2022 |
| Jan 21, 2022 | C | Apt 1 · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INOPERATIVE BASE RADIATORS AT NORTH AND WEST WALL IN THE 4th ROOM FROM NORTH AT EAST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 27, 2022 |
| Dec 20, 2017 | A | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR .. AT PUBLIC HALL, 1st STORY | Mar 25, 2018 |
| Dec 19, 2017 | B | Apt 1 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM NORTH AT CENTER LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Jan 23, 2018 |
| Jul 18, 2017 | A | Apt 1 · § 27-2065 ADM CODE PROVIDE VENTILATION FOR WATER CLOSET COMPARTMENT AND/OR BATHROOM AND FILE APPLICATION FOR APPROVAL BEFORE DOING WORK ... IN THE BATHROOM LOCATED AT B-ROOM 1, B-ROOM AT WEST , SECTION AT NORTHWEST | Oct 21, 2017 |
| Jul 18, 2017 | B | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF GARBAGE AT FIRE-PASSAGEWAY AT EAST AT CELLAR | Aug 22, 2017 |
| Jul 18, 2017 | A | § 27-2065 ADM CODE PROVIDE VENTILATION FOR WATER CLOSET COMPARTMENT AND/OR BATHROOM AND FILE APPLICATION FOR APPROVAL BEFORE DOING WORK AT 1ST FLOOR AT EAST AND NORTH EAST SECTION | Oct 21, 2017 |
| Jun 4, 2008 | B | D26-19.07 ADM CODE INSTALL AND MAINTAIN SUFFICIENT LIGHT OR LIGHTS OF AT LEAST 40 WATTS INCANDESCENT OR EQUIVALENT EACH, TO LIGHT ADEQUATELY FROM SUNSET TO SUNRISE THE REAR YARD. | Jul 9, 2008 |
| Jun 4, 2008 | A | D26-16.01 ADM CODE PROVIDE A SUITABLE STRAINER FOR THE DRAIN FRONT ENTRANCE TO CELLAR. | Sep 7, 2008 |
| Jun 4, 2008 | A | D26-16.03 ADM CODE REPAIR THE BROKEN OR DEFECTIVE RAIN LEADER NOT CONNECTED TO CAST IRON RAIN DRAIN REAR YARD. | Sep 7, 2008 |