Bronx · Block 2850 · Lot 60 · 10453

1775 Walton Avenue

9 floors · 63 apartments · 62,685 sq ft · built 2007 · class D1 · owner of record: 1785 Walton Avenue Associates Lp

460open violations
$208,185ECB/OATH penalties owed
104HPD class C (immediately hazardous)
64dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 64 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 64 days
Annual
Annual boiler inspection (4 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-11-20 (Accepted). Agency page

Dec 31, 2026
in 64 days
4 of 4 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 80 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 62,685 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 185 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 185 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 308 days
Registered through 2027-09-01
Facade inspection report (Cycle 10B) Applies
Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. DOB facade records for this building show $1,395,000 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2028
in 481 days
No Cycle 10 report on record yet
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1160 days
Next cycle year 2029
Energy audit and retro-commissioning (2030) Likely applies
Local Law 87 · Calendar year 2030
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2850). Agency page

Dec 31, 2030
in 1525 days
Next due 2030

Open violations

ECB / OATH (55) · $208,185 owed
IssuedViolationHearingBalance
Jul 1, 2026Elevators CLASS - 1
ELEVATOR WAS PREVIOUSLY ISSUED AN RTS CLASS 1 ON JUNE 15, 2026. UPON REINSPECTION, THE ELEVATOR WAS FOUND TO REMAIN OUT OF SERVICE, AND THE PREVIOUSLY CITED HAZARDOUS CONDITION HAD NOT BEEN CORRECTED. THE CONTI
#39194499J
Sep 4, 2026
DEFAULT
$12,500
Jul 1, 2026Elevators CLASS - 1
ELEVATOR WAS PREVIOUSLY ISSUED AN RTS CLASS 1 ON JUNE 15, 2026. UPON REINSPECTION, THE ELEVATOR WAS FOUND TO REMAIN OUT OF SERVICE, AND THE PREVIOUSLY CITED HAZARDOUS CONDITION HAD NOT BEEN CORRECTED. THE CONTI
#39194498H
Sep 4, 2026
DEFAULT
$12,500
Jun 15, 2026Elevators CLASS - 1
CLASS 1 RTS:FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER PASSENGER ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION,DEVICE IS FOUND TO BE OUT OF SERVICE,, CREATING A HAZARDOUS CONDITION PER
#39192531L
Sep 4, 2026
DEFAULT
$6,250
Jun 15, 2026Elevators CLASS - 1
CLASS 1 RTS:FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER PASSENGER ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, DEVICE IS FOUND TO BE OUT OF SERVICE,CREATING A HAZARDOUS CONDITION PER
#39192532N
Sep 4, 2026
DEFAULT
$6,250
Apr 20, 2026Local Law CLASS - 2
FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8B REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #814452. AGG1: PRIOR NOV 37026165Y UNDER 28-302
#37036580K
Jul 31, 2026
DEFAULT
$10,000
Feb 19, 2026Boilers CLASS - 2
I FOUND A PATTERSON KELLY N1500-2 HOT WATER BOILER THE WATER PUMP IS DISCONNECTED SO BOILER IS NOT OPERATIONAL/CORRECT ALL VIOLATING CONDITION/SUBMIT A CERTIFICATE OF CORRECTION
#39177859J
May 1, 2026
DEFAULT
$6,250
Feb 19, 2026Boilers CLASS - 2
I FOUND A PATTERSON KELLY N1500-2 HOT WATER BOILER THAT THE SAFETY RELIEF VALVE HAS NO LABEL/FRESH AIR LOUVER NOT WORKING WITH THE BOILERS/CORRECT ALL VIOLATING CONDITION/SUBMIT CERTIFICATE OF CORRECTION
#39177855M
May 1, 2026
DEFAULT
$6,250
Sep 30, 2025Unknown CLASS - 2
OBSERVED SIDEWALK SHED NOT MAINTAINED: MISSING MUDSILL AND EXPOSED BOLTS PRESENTING POTENTIAL EYE-GOUGE HAZARD FOR PEDESTRIANS, ESPECIALLY CHILDREN. SHED APPEARS UNSTABLE. IN VIOLATION OF BC 3301.2 / BC 3303.4
#39545462H
Dec 14, 2026
DEFAULT
$10,000
Sep 30, 2025Construction CLASS - 2
OBSERVED SIDEWALK SHED WITH NO DOB PERMIT OR CERTIFICATE POSTED ONSITE, IN VIOLATION OF BC 3314.1 / BC 3301.2. MAINTAIN DOCUMENTATION ONSITE.
#39545461X
Nov 24, 2026
DEFAULT
$1,500
Sep 19, 2024Elevators CLASS - 2
RESPONDING TO A 311 ELEVATOR COMPLAINT, UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT-OF-SERVICE. AS PER 1RCNY 11-02. THIS DEVICE PROVIDES SERVICE IN A 9 STORY BUILDING, REMEDY; RESTORE TO SERVICE IMMEDIATELY
#39125364N
Jan 13, 2026
DEFAULT
$6,250
May 7, 2024Unknown CLASS - 2
AT A OCCUPIED BUILDING WITH SIDEWALK SHED. UPON REVIEWING DEPARTMENT OF BUILDING RECORDS, I NOTICED SIDEWALK SHED PERMIT #X00123453 EXPIRED 06/06/2022 AND NO VALID PERMIT WAS FOUND. CODE REQUIRES VALID PERMIT F
#39528340P
Nov 24, 2025
IN VIOLATION
$1,250
May 7, 2024Construction CLASS - 2
AT TIME OF MY INSPECTION OF A SIDEWALK SHED AT A 8 STORY OCCUPIED BUILDING. I NOTICED THAT SIDEWALK SHED IS MISSING A INFORMATION PANEL. THIS CREATES AN UNSAFE SITUATION INCASE OF AN EMERGENCY FOR FIRST RESPOND
#39528341R
Jan 17, 2025
IN VIOLATION
$1,250
Apr 11, 2024Local Law CLASS - 2
FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #914452. REMEDY: SUBMIT ACCEPTABLE REQU
#37027950Y
Jan 17, 2025
IN VIOLATION
$1,250
Jan 16, 2024Local Law CLASS - 2
FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8B REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 CONTROL #814452. AGG1: PRIOR NOV 37022086Y UNDER 28-302.5.
#37026165Y
Oct 18, 2024
IN VIOLATION
$3,125
Jan 3, 2024Construction CLASS - 1
UNLAWFUL ACTS: FAILURE TO COMPLY WITH COMMISSIONER'S ORDERS STATED IN ECB# 35473942L ISSUED ON 09/29/2020. PURSUANT TO 28-201.1 AND1RCNY 102-01., COMPLY WITH COMMISSIONER'S ORDER; FILE A CERTIFICATE OF CORRECTI
#39102646J
May 3, 2024
IN VIOLATION
$2,500
May 24, 2023Elevators CLASS - 2
RESPONDING TO A 311 COMPLAINT ON ELEVATOR, UPON INSPECTION OF DEVICE CLASS 2 VIOLATION ISSUED FOR INCORRECT NYC DEVICE CAR NUMBER, REMEDY; PROVIDE UP TO DATE NUMBER,
#39087214N
Aug 4, 2023
DEFAULT
$6,250
May 24, 2023Elevators CLASS - 2
RESPONDING TO A 311 COMPLAINT ON ELEVATOR,UPON INSPECTION CLASS 2 VIOLATION WAS ISSUED FOR INCORRECT NYC DEVICE NUMBER, REMEDY, PROVIDE CORRECT NUMBER,
#39087215P
Aug 4, 2023
DEFAULT
$6,250
Jan 23, 2023Elevators CLASS - 2
CLASS 2 VIOLATION ISSUED, RESPONDING TO A 311 ELEVATOR COMPLAINT, UPON INSPECTION OF DEVICE VIOLATION WAS FOUND, ITEMS ARE, INCORRECT NYC# DEVICE NUMBER ON DEVICE, REMEDY; PROVIDE CORRECT DEVICE NUMBER, ) EXPIR
#39078205R
Sep 5, 2023
DEFAULT
$3,125
Oct 8, 2021Local Law CLASS - 2
FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8B REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL#814452.REM:FILE ACCEPTABLE REPORT.
#37022068Y
May 20, 2022
DEFAULT
$6,250
Aug 15, 2021Elevators CLASS - 1
ELEVATOR NOT IN SERVICE, RETURN TO SERVICE
#39046046M
Oct 1, 2021
DEFAULT
$6,250
Aug 15, 2021Elevators CLASS - 1
ELEVATOR NOT IN SERVICE, RETURN BACK TO SERVICE
#39046047Y
Oct 1, 2021
DEFAULT
$6,250
Aug 11, 2021Boilers CLASS - 2
FOUND MANUAL RESET LOW WATER CUT OFF CORRODED AND DEFECTIVE, SPILL SWITCHES MISSING AT BOTH BAROMETRIC DAMPERS, TEMP GAUGE ON SUPPLY LINE CORRODED AND DEFECTIVE,
#39045825R
Oct 1, 2021
DEFAULT
$3,125
Aug 11, 2021Boilers CLASS - 2
FOUND AO SMITH HW 300 NOT OPERABLE TAKEN APART DUE TO LEAK, AS PER SUPER GOING TO BE REPLACED.
#39045824P
Oct 1, 2021
DEFAULT
$3,125
Jun 8, 2021Boilers CLASS - 2
SPILL SWITCHES FOR THREE BOILERS NOT INSTALLED-FLUE PIPE FOR REMOVED BOILER CAPPED W/PROHIBITED MATERIAL-CORRODED DOMESTIC HW PIPING-GAS REGULATORS NOT VENTED OUTDOORS-HW PIPES NOT CAPPED-DEFECTED THERMO. ON HW
#39042406Z
Jul 30, 2021
DEFAULT
$3,125
May 26, 2021Construction CLASS - 2
PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION.NOTE AT TIME OFINSPECTION OBSERVED A HD SWS AT EXP1 IN FRONT OF BUILDING.PEDESTRIAN WALKING UNDER THIS SIDEWALK SHED.ALSO OBSERVED MISSING SCREWCAPS SEVERA
#35558523J
Aug 20, 2021
DEFAULT
$10,000
May 26, 2021Construction CLASS - 2
SIDEWALK SHED PARAPET INFORMATION PANEL.NOTE AT THE TIME OF INSPECTIONOBSERVED A HD SIDEWALK SHED AT EXP1 FRONT OF THE BUILDING.PEDESTRIAN WALKING UNDER THIS SWS.ALSO OBSERVED PARAPET INFORMATION PANEL MISSING
#35558522H
Aug 20, 2021
DEFAULT
$6,250
May 26, 2021Construction CLASS - 2
TEMPORARY CONSTRUCTION EQUIPMENT(SWS)EXPIRED PERMIT.NOTE AT THE TIME OF INSPECTION OBSERVED A HD SIDEWALK SHED INSTALLED AT EXP1 INFRONT OF BUILDING.PEDESTRIAN WALKING UNDER THIS SWS.ALSO OBSERVED IN DOB SYSTEM
#35558521X
Aug 20, 2021
DEFAULT
$6,250
Mar 3, 2021Elevators CLASS - 1
RESTORE DEVICE TO SERVICE SO THAT INSPECTION CAN BE MADE BY THIS DEPARTMENT.
#39037032R
Apr 30, 2021
DEFAULT
$0
Jan 20, 2021Elevators CLASS - 1
CLASS 1 VIOLATION ISSUED RTS, UPON INSPECTION OF ELEVATOR DEVICE WAS FOUND OUT-OF-SERVICE CREATING A HAZARDOUS CONDITION PER 1RCNY 11-02. REMEDY; RESTORE TO SERVICE IMMEDIATELY.
#39035118Z
May 7, 2021
IN VIOLATION
$0
Dec 2, 2020Construction CLASS - 2
FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #35459148N ISSUED ON 10/28/2019,AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28.201.1 AND 1 RCNY 102-01(D)(2).AN ACCEPTIBLE CERT
#37020501R
Nov 29, 2021
DEFAULT
$3,125
Sep 29, 2020Construction CLASS - 1
FILED A CERTIFICATE,FORM,APPLICATION,ETC. CONTAINING A MATERIAL FALSE STATEMENT. OWNER/REP CHECKED NO TO OCCUPANCY QUESTION ON PW1/SECTION 26. BUILDING'S DWELLING UNITS ARE OCCUPIED AT TIME OF INSPECTION. REMED
#35473942L
Aug 13, 2021
DEFAULT
$25,000
Jun 21, 2020Elevators CLASS - 1
CLASS 1. R,T,S UPON INSPECTION. THE DEVICE IS FOUND TO BE OUT- OF- SERVICE AS PER 1RCNY 11-02, REMEDY; RESTORE TO SERVICE IMMEDIATELY AND, NOTIFY NYCDOB THE DEVICE HAS BEEN RETURNED TO SERVICE, CALL 212-393-243
#39024268K
Jan 22, 2021
IN VIOLATION
$0
Jun 21, 2020Elevators CLASS - 2
CLASS 2; CAR GO TO 8 FLOOR CAR STOP AND JAMP THE MOVE ONCE MORE AND STUCK, REMEDY REPAIR, MOTOR ROOM NO ACCESS PROVIDE KEYS ON SITE, DIRTY PIT CLEAN,
#39024269M
Mar 12, 2021
IN VIOLATION
$0
May 14, 2020Elevators CLASS - 1
97-X-17, ENTIRE DEVICE INOPERATIVE REPAIR AND RESTORE TO SERVICE IMMEDIATELY . RE INSPECTION REQUIRED.
#39022294P
Jul 31, 2020
DEFAULT
$6,250
Feb 11, 2020Construction CLASS - 2
AT TIME OF INSPECTION I OBSERVED MINOR DISREPAIR CONDITION WITH CRACKS AND WATER MARKS ON ALL BEDROOM CEILING ALONG REAR WALL BY THE WINDOWS AT APT # 7A., REPAIR AND/OR REPLACE
#39017364P
Jul 24, 2020
DEFAULT
$3,125
Jan 14, 2020Construction CLASS - 2
FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#38268811H ISSUED ON 3/20/19 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01(D)(2).AN ACEPTIBLE CERT
#37017377L
Sep 18, 2020
DEFAULT
$3,125
Oct 28, 2019Construction CLASS - 2
FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: AT TIME OF INSPECTION I OBSERVED AT EXP#1 A DISLODGED & IMMINENT DANGER OF FALLINGSECTION OF BRICK VENEER OF APPROX 3X5 FEET AREA AT 2ND FL CORNER LOOSE
#35459148N
Dec 20, 2019
STIPULATION/IN-VIO
$0
Sep 16, 2019Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING EXTERIOR WALLS OR APPURTENANCES.AT THE TIME OF INSPECTION,NOTED: A DISLOGED AND IMMINET DANGER OF FALLING SECTION OF BRICK VENEER OF APPROXIMATELY 3'X5'FEET AREA AT 2ND FLOOR CORNER
#35407119J
Nov 1, 2019
IN VIOLATION
$0
Jul 18, 2019Elevators CLASS - 1
97X17 RESTORED TO SERVICE SO A FULL INSPECTION CAN BE MADE BY THIS DEPT.
#38268305P
Jan 24, 2020
DEFAULT
$7,935
Jun 13, 2019Elevators CLASS - 2
03M07,39O02,02X10,41I10,41T07,68B07,68M07,40I10,52U07,53U07,97O02,23I10,39D06,64M07,42Q03,60Q03;(03)PROVIDE MISSING RAILING(39)CLEAN DIRTY CAR TOP(02)REPAIR TWO-WAY COMMUNICATION(41)REPAIR DOOR(41)LABEL DOOR(68
#38270177M
Jan 24, 2020
DEFAULT
$0
Mar 20, 2019Elevators CLASS - 2
67.X.10,64.M.07,39.O.02,70.O,02,97.O.02,14.M.07,52.U.07,53.U.07,03.I.10,05.E.10,34.D.06,23.I.10,68.B.07,60.Q.03,42.D.06,59.B.07=(67) REPAIR PHONE (64) PROVIDE IN CAR I.D. (39/CLEAN CAR TOP (7) CLEAN PIT (97) CL
#38268811H
May 17, 2019
STIPULATION/IN-VIO
$0
Dec 10, 2018Construction CLASS - 1
97X17,12M07,40P16,70P16. 19X17-RMDY REPAIR AND NOTIFY NYCDOB OF RESTORE TO SERVICE IMMEDIATELY. 12M07-RMDY REPAIR CAR LIGHT TO BE WORKING AT ALL TIMES WHENEVER ELEVATOR DOOR IS OPEN; 40P16-RMDY:PROVIDE KEYS F
#38266820K
Apr 12, 2019
IN VIOLATION
$0
Oct 15, 2018Local Law CLASS - 2
FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#814452REM:SUBMIT REQUIRED TECHNICAL REPORT.
#37013671Y
Jul 26, 2019
DEFAULT
$6,250
Jul 10, 2018Elevators CLASS - 2
64M07,15M07,70O02,78H14,14M07,100M07,40P07-64M07)REMEDY PROVIDE NYC IN CAR DEVICE PLATE. 15M07)REMEDY PROVIDE IN CAR CAPACITY PLATE. 70O02)REMEDY CLEAN HOIST PIT. 78H14)REMEDY SHORTEN TENSION WEIGHT ROPE. 14M07
#38264067K
Jan 25, 2019
DEFAULT
$0
Aug 8, 2017Elevators CLASS - 2
ENTIRE DEVICE/BYC DEVICE #;INOPERATIVE/IMPROPER;REPAIR/REPLACE&PROVIDEREM:REPAIR AND RETURN TO SERVICE/REPLACE IMPROPER DEVICE #2P10838
#37005901K
Feb 9, 2018
DEFAULT
$0
Mar 29, 2017Elevators CLASS - 2
2L10,15M7,57BB15,70O2
#38253961L
Oct 20, 2017
WRITTEN OFF
$0
Mar 29, 2017Elevators CLASS - 2
2L10,57BB15,70O2
#38253960J
May 19, 2017
DEFAULT
$0
Aug 2, 2016Elevators CLASS - 1
97X10.RESTORE TO SERVICE IMMEDIATELY.
#38244682Y
Oct 14, 2016
IN VIOLATION
$0
Jul 20, 2016Elevators CLASS - 2
02L10,11D10,14M07,15M07,39P16,70P16,68M07,57BB15.11D10 STOP(SWITH)UNSECURED(REPAIR).
#38244465H
Oct 14, 2016
IN VIOLATION
$0
Jul 20, 2016Elevators CLASS - 1
97X10.RESTORE BACK TO SERVICE IMMEDIATELY FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.
#38244464X
Oct 14, 2016
IN VIOLATION
$0
Jun 16, 2016Elevators CLASS - 2
01D06,03M11,14M11,60Q03,59M15,68B07. 01D06-SECURE STOP SWITCH IN CAR; 03M11-REPLACE HANDRAIL IN CAR; 59M15-PERFORM BRAKE MAINTENANCE AND TAGDEVICE; 68B07-PROVIDE UPDATED MAINTENANCE LOG.
#38242548Y
Aug 5, 2016
STIPULATION/IN-VIO
$0
Jun 16, 2016Elevators CLASS - 2
97X10 REPAIR ELEVATOR AND RETURN TO SERVICE AS SOON AS POSSIBLE SO THAT A COMPLETE INSPECTION CAN BE MADE BY THIS DEPARTMENT.
#38242549X
Aug 5, 2016
STIPULATION/IN-VIO
$0
Jun 4, 2016Elevators CLASS - 2
97X10. UPON INSP I FOUND DEVICE 2P10938 AKA #1 CAR OUT OF SERVICE BETWEEN LOBBY & BASEMENT. DOB RECORDS SHOW THIS DEVICE AS ACTIVE. RESTORE TO SERVICE SO A FULL TEST CAN BE CONDUCTED BY THIS AGENCY.
#38243197X
Jul 29, 2016
STIPULATION/IN-VIO
$0
Mar 30, 2016Elevators CLASS - 1
C/U01-X-10,70-O-02,57-BB-15:01-X-10-STOP SWITCH CAR NEEDS (REPAIR OR REPLACE)(212)393-2531.CALL THESE # TO RESTORE TO SERVICE (212)393-2438.
#38241731H
Jun 24, 2016
IN VIOLATION
$0
Mar 30, 2016Elevators CLASS - 2
02L10,14M11,15M11,70O02,57BB15. 02L10-OUTSIDE COMMUNICATION (REPAIR)
#38241732J
May 20, 2016
STIPULATION/IN-VIO
$0
DOB (37)
IssuedViolationStatus
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#06164
DOB VIOLATION - ACTIVE
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#06166
DOB VIOLATION - ACTIVE
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#06165
DOB VIOLATION - ACTIVE
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#06167
DOB VIOLATION - ACTIVE
Dec 1, 2024FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2400698
DOB VIOLATION - ACTIVE
Sep 23, 2024LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
#05801
DOB VIOLATION - ACTIVE
Sep 23, 2024LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
#05800
DOB VIOLATION - ACTIVE
Sep 23, 2024LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
#05799
DOB VIOLATION - ACTIVE
Sep 23, 2024LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
#05798
DOB VIOLATION - ACTIVE
Dec 1, 2023FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2300704
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
#07158
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
#07157
DOB VIOLATION - ACTIVE
Apr 25, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
#08639
DOB VIOLATION - ACTIVE
Apr 25, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
#08640
DOB VIOLATION - ACTIVE
Apr 25, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
#08641
DOB VIOLATION - ACTIVE
Apr 25, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
#08642
DOB VIOLATION - ACTIVE
Feb 22, 2023NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9B TECHNICAL REPORT BY 2/21/2023
#01032
DOB VIOLATION - ACTIVE
Dec 1, 2021FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2101513
DOB VIOLATION - ACTIVE
Nov 10, 2021FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00194
DOB VIOLATION - ACTIVE
Nov 10, 2021FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00193
DOB VIOLATION - ACTIVE
May 26, 2021FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00207
DOB VIOLATION - ACTIVE
Apr 14, 2021FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00125
DOB VIOLATION - ACTIVE
Dec 23, 2020FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00226
DOB VIOLATION - ACTIVE
Sep 16, 2020FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00214
DOB VIOLATION - ACTIVE
Sep 2, 2020FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#02190
DOB VIOLATION - ACTIVE
Dec 11, 2019FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00224
DOB VIOLATION - ACTIVE
Oct 17, 2019FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00457
DOB VIOLATION - ACTIVE
Sep 23, 2019ELEVATOR

#9028/662917
DOB VIOLATION - ACTIVE
Sep 23, 2019ELEVATOR

#9028/662916
DOB VIOLATION - ACTIVE
Mar 6, 2019FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00398
DOB VIOLATION - ACTIVE
Feb 21, 2019FACADE SAFETY PROGRAM

#HAZ88033
DOB VIOLATION - ACTIVE
Nov 2, 2016FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00131
DOB VIOLATION - ACTIVE
Oct 19, 2016FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00154
DOB VIOLATION - ACTIVE
Jun 29, 2016FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00143
DOB VIOLATION - ACTIVE
May 30, 2014(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2012 CAT 1 INSP/TST
#09156
DOB VIOLATION - ACTIVE
May 30, 2014(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2012 CAT 1 INSP/TST
#09157
DOB VIOLATION - ACTIVE
Dec 13, 2011ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2010 INSPECTION/TEST
#02158
DOB VIOLATION - ACTIVE
DOB NOW Safety (65)
IssuedViolationStatus
Oct 2, 2026Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2025 Periodic Inspection Report
Active
Oct 2, 2026Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2025 Cat1 Test Report
Active
Sep 30, 2026AEUHAZ FTC-AEU-HAZ
Active
Sep 30, 2026AEUHAZ FTC-AEU-HAZ
Active
Sep 30, 2026AEUHAZ FTC-AEU-HAZ
Active
Sep 30, 2026AEUHAZ FTC-AEU-HAZ
Active
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Aug 29, 2025Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Report
Active
Aug 29, 2025Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Report
Active
Dec 1, 2024Energy Grade - LL33 FTP-EN-EGRDEA
Active
Sep 23, 2024Boiler LBLVIO
Violation Issued-Failure To File 2023 External Low Pressure Inspection Report
Active
Sep 23, 2024Boiler LBLVIO
Violation Issued-Failure To File 2023 External Low Pressure Inspection Report
Active
Sep 23, 2024Boiler LBLVIO
Violation Issued-Failure To File 2023 External Low Pressure Inspection Report
Active
Sep 23, 2024Boiler LBLVIO
Violation Issued-Failure To File 2023 External Low Pressure Inspection Report
Active
Sep 11, 2024Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Report
Active
Sep 11, 2024Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Report
Active
Dec 1, 2023Energy Grade - LL33 FTP-EN-EGRDEA
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
Aug 25, 2023Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2021 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2020 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2019 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2018 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Report
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Active
Apr 25, 2023Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2022 INSPECTION REPORT
Active
Apr 25, 2023Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2022 INSPECTION REPORT
Active
Apr 25, 2023Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2022 INSPECTION REPORT
Active
Apr 25, 2023Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2022 INSPECTION REPORT
Active
Feb 22, 2023Facades FISPNRF
CYCLE 9B NO REPORT FILED
Active
Dec 1, 2021Energy Grade - LL33 FTP-EN-EGRDEA
Active
Nov 10, 2021AEUHAZ FTC-AEU-HAZ
Active
Nov 10, 2021AEUHAZ FTC-AEU-HAZ
Active
May 26, 2021AEUHAZ FTC-AEU-HAZ
Active
Apr 14, 2021AEUHAZ FTC-AEU-HAZ
Active
Dec 23, 2020AEUHAZ FTC-AEU-HAZ
Active
Sep 16, 2020AEUHAZ FTC-AEU-HAZ
Active
Sep 2, 2020AEUHAZ FTC-AEU-HAZ
Active
Dec 11, 2019AEUHAZ FTC-AEU-HAZ
Active
Oct 17, 2019AEUHAZ FTC-AEU-HAZ
Active
Mar 6, 2019AEUHAZ FTC-AEU-HAZ
Active
Feb 21, 2019Facades FISP
CYCLE 8B UNSAFE REPORT FILED
Active
Jul 31, 2018Facades FISPNRF
FAILED TO FILE FISP CYCLE 8B TECHNICAL REPORT BY 02/21/2018
Active
Nov 2, 2016AEUHAZ FTC-AEU-HAZ
Active
Oct 19, 2016AEUHAZ FTC-AEU-HAZ
Active
Jun 29, 2016AEUHAZ FTC-AEU-HAZ
Active
May 30, 2014Elevators ACC1
Active

Showing 60 of 65. Full list on the agency site.

HPD (306) · C 104 · B 160 · A 42
IssuedClassViolationCorrect by
Oct 19, 2026CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES AT COMPACTOR CLOSET, 9th STORYNov 14, 2026
Oct 13, 2026CApt 6F · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6F, 6th STORY, 3rd APARTMENT FROM NORTH AT EASTNov 8, 2026
Oct 13, 2026BApt 6F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 6F, 6th STORY, 3rd APARTMENT FROM NORTH AT EASTNov 17, 2026
Oct 13, 2026BApt 6F · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 6F, 6th STORY, 3rd APARTMENT FROM NORTH AT EASTNov 17, 2026
Oct 5, 2026BApt 8D · § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET ... IN THE BATHROOM LOCATED AT APT 8D, 8th STORY, 1st APARTMENT FROM EAST AT SOUTHNov 9, 2026
Oct 5, 2026BApt 8D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 8D, 8th STORY, 1st APARTMENT FROM EAST AT SOUTHNov 9, 2026
Oct 5, 2026C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE [DOOR] DOOR TO REFUSE/TRASH ROOM AT PUBLIC HALL, 8th STORYOct 19, 2026
Oct 5, 2026C§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CRACKED GLASS AT 1ST DOOR FROM NORTH AT VESTIBULE DOOR AT PUBLIC HALL, 1st STORYOct 11, 2026
Oct 5, 2026B§ 27-2005 HMC: REFIT DOOR TO REFUSE/TRASH ROOM AT PUBLIC HALL, 8th STORYNov 9, 2026
Oct 5, 2026BApt 8D · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... OBSERVED [GREATER THAN TEN SQFT] AT CEILING, AND WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 8D, 8th STORY, 1st APARTMENT FROM EAST AT SOUTHNov 9, 2026
Oct 5, 2026A§ 27-2042 ADM CODE PROVIDE A MIRROR IN SELF-SERVICE ELEVATOR ARRANGED SO AS TO ENABLE A PERSON ENTERING, TO VIEW INSIDE OF ELEVATOR NUMBER ( WEST 1) ELEVATOR AT PUBLIC HALLJan 8, 2027
Sep 3, 2026BApt 6F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 6F, 6th STORY, 3rd APARTMENT FROM NORTH AT EASTOct 8, 2026
Aug 21, 2026C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT 2ND HOPPER CHUTE DOOR FROM NORTH AT WEST AT COMPACTOR CLOSET, 3rd STORYSep 4, 2026
Aug 21, 2026C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH AT COMPACTOR CLOSET DOOR AT PUBLIC HALL, 1st STORYSep 4, 2026
Aug 21, 2026A§27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMANov 24, 2026
Aug 21, 2026B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AND ASSEMBLIES AT COMPACTOR CLOSET DOOR AT PUBLIC HALL, 1st STORYSep 25, 2026
Jul 22, 2026BApt 6F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 6F, 6th STORY, 3rd APARTMENT FROM SOUTH AT WESTAug 26, 2026
Jul 22, 2026CApt 6F · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6F, 6th STORY, 3rd APARTMENT FROM SOUTH AT WESTAug 17, 2026
May 8, 2026A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Aug 11, 2026
Apr 24, 2026CApt 6F · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6F, 6th STORY, 3rd APARTMENT FROM NORTH AT EASTMay 20, 2026
Apr 24, 2026BApt 6F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT THE CEILING IN THE BATHROOM LOCATED AT APT 6F, 6th STORY, 3rd APARTMENT FROM NORTH AT EASTMay 29, 2026
Apr 24, 2026BApt 6F · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE BATHROOM LOCATED AT APT 6F, 6th STORY, 3rd APARTMENT FROM NORTH AT EASTMay 29, 2026
Feb 17, 2026C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH AT 2ND HOPPER CHUTE DOOR FROM NORTH AT WEST AT COMPACTOR CLOSET, 6th STORYMar 3, 2026
Feb 17, 2026BApt 6F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 6F, 6th STORY, 3rd APARTMENT FROM NORTH AT EASTMar 24, 2026
Feb 17, 2026BApt 6F · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK OVER CEILING IN THE BATHROOM LOCATED AT APT 6F, 6th STORY, 3rd APARTMENT FROM NORTH AT EASTMar 24, 2026
Feb 17, 2026B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AND ASSEMBLIES AT 2ND HOPPER CHUTE DOOR FROM NORTH AT WEST AT COMPACTOR CLOSET, 6th STORYMar 24, 2026
Feb 17, 2026B§ 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION AT LIGHT FIXTURE (''B'' STAIR) AT NORTH WALL AT PUBLIC HALL STAIRS, 4th STORYMar 24, 2026
Feb 17, 2026B§ 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION AT LIGHT FIXTURE (''B'' STAIR) AT SOUTH WALL AT PUBLIC HALL STAIRS, 3rd STORYMar 24, 2026
Feb 17, 2026B§ 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION AT LIGHT FIXTURE (''B'' STAIR) AT NORTH WALL AT PUBLIC HALL STAIRS, 2nd STORYMar 24, 2026
Jan 6, 2026AApt 6A · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING IN THE 4th ROOM FROM NORTH LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM NORTH AT EASTApr 11, 2026
Jan 6, 2026BApt 6A · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM NORTH AT EASTFeb 10, 2026
Jan 6, 2026BApt 6A · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM NORTH AT EASTFeb 10, 2026
Jan 6, 2026CApt 6A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM NORTH AT EASTFeb 1, 2026
Jan 6, 2026BApt 6A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COVER PLATE, AT ELECTRICAL OUTLETS IN THE ENTIRE APARTMENT LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM NORTH AT EASTFeb 10, 2026
Dec 23, 2025BApt 1B · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY, 3rd APARTMENT FROM SOUTH AT WESTJan 27, 2026
Dec 23, 2025BApt 4A · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM NORTH AT EASTJan 27, 2026
Dec 23, 2025BApt 5A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MORE THAN 10 SQT FT INSIDE CLOSET IN THE FOYER LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM NORTH AT EASTJan 27, 2026
Dec 23, 2025BApt 4A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQ FT OF MOLD AT CEILING IN THE BATHROOM LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM NORTH AT EASTJan 27, 2026
Dec 23, 2025BApt 9B · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 9B, 9th STORY, 3rd APARTMENT FROM SOUTH AT WESTJan 27, 2026
Dec 23, 2025AApt 5A · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING IN THE BATHROOM LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM NORTH AT EASTMar 28, 2026
Dec 23, 2025BApt 9B · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 9B, 9th STORY, 3rd APARTMENT FROM SOUTH AT WESTJan 27, 2026
Dec 18, 2025CApt 2D · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHDec 18, 2025
Dec 18, 2025CApt 2D · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHJan 13, 2026
Dec 18, 2025C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOMDec 24, 2025
Dec 18, 2025CApt 3B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 3rd STORY, 3rd APARTMENT FROM SOUTH AT WESTJan 13, 2026
Dec 15, 2025CApt 9E · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 9E, 9th STORY, 1st APARTMENT FROM SOUTH AT WESTDec 14, 2025
Dec 15, 2025C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOMDec 21, 2025
Dec 15, 2025CApt 9D · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 9D, 9th STORY, 1st APARTMENT FROM EAST AT SOUTHDec 14, 2025
Dec 15, 2025CApt 9D · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 9D, 9th STORY, 1st APARTMENT FROM EAST AT SOUTHDec 14, 2025
Dec 11, 2025C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOMDec 17, 2025
Dec 8, 2025BApt 2C · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS THAT IS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 2nd STORY, 2nd APARTMENT FROM SOUTH AT Jan 12, 2026
Dec 8, 2025C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOMDec 14, 2025
Dec 8, 2025CApt 2C · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WESTJan 3, 2026
Dec 8, 2025CApt 2C · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WESTJan 3, 2026
Dec 8, 2025BApt 2C · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES THAT IS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEJan 12, 2026
Dec 3, 2025BApt 6F · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 6F, 6th STORY, 3rd APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 18131682 ISSUED 03-AUG-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.Jan 7, 2026
Dec 1, 2025CApt 3C · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3C , 3rd STORY, 2nd APARTMENT FROM SOUTH AT WESTDec 1, 2025
Dec 1, 2025CApt 3C · § 27-2028, 2032 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FROM AN APPROVED CENTRAL HEATING SYSTEM, OR AN APPROVED SYSTEM OF GAS OR ELECTRICAL HEATING IN GOOD OPERATING CONDITION FOR THE DWELLING UNIT IN THE ENTIRE APARTMENT LOCATED AT APT 3C , 3rd STORY, 2nd APARTMENT FROM SOUTH AT WESTDec 1, 2025
Nov 24, 2025BApt 4A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 4th ROOM FROM NORTH LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM NORTH AT EASTDec 29, 2025
Nov 24, 2025BApt 4A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK OVER CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM NORTH AT EASTDec 29, 2025

Showing 60 of 306. Full list on the agency site.

Issued in the last 120 days

DateSourceWhatNow
Oct 19, 2026HPD CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES AT COMPACTOR CLOSET, 9th STORYOpen
Oct 13, 2026HPD CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6F, 6th STORY, 3rd APARTMENT FROM NORTH AT EASTOpen
Oct 13, 2026HPD B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 6F, 6th STORY, 3rd APARTMENT FROM NORTH AT EASTOpen
Oct 13, 2026HPD B§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 6F, 6th STORY, 3rd APARTMENT FROM NORTH AT EASTOpen
Oct 5, 2026HPD B§ 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET ... IN THE BATHROOM LOCATED AT APT 8D, 8th STORY, 1st APARTMENT FROM EAST AT SOUTHOpen
Oct 5, 2026HPD B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 8D, 8th STORY, 1st APARTMENT FROM EAST AT SOUTHOpen
Oct 5, 2026HPD C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE [DOOR] DOOR TO REFUSE/TRASH ROOM AT PUBLIC HALL, 8th STORYOpen
Oct 5, 2026HPD C§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CRACKED GLASS AT 1ST DOOR FROM NORTH AT VESTIBULE DOOR AT PUBLIC HALL, 1st STORYOpen
Oct 5, 2026HPD B§ 27-2005 HMC: REFIT DOOR TO REFUSE/TRASH ROOM AT PUBLIC HALL, 8th STORYOpen
Oct 5, 2026HPD B§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... OBSERVED [GREATER THAN TEN SQFT] AT CEILING, AND WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 8D, 8th STORY, 1st APARTMENT FROM EAST AT SOUTHOpen
Oct 5, 2026HPD A§ 27-2042 ADM CODE PROVIDE A MIRROR IN SELF-SERVICE ELEVATOR ARRANGED SO AS TO ENABLE A PERSON ENTERING, TO VIEW INSIDE OF ELEVATOR NUMBER ( WEST 1) ELEVATOR AT PUBLIC HALLOpen
Oct 2, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Periodic Inspection ReportOpen
Oct 2, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Cat1 Test ReportOpen
Sep 30, 2026DOB SafetyAEUHAZ: Open
Sep 30, 2026DOB SafetyAEUHAZ: Open
Sep 30, 2026DOB SafetyAEUHAZ: Open
Sep 30, 2026DOB SafetyAEUHAZ: Open
Sep 3, 2026HPD B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 6F, 6th STORY, 3rd APARTMENT FROM NORTH AT EASTOpen
Aug 21, 2026HPD C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT 2ND HOPPER CHUTE DOOR FROM NORTH AT WEST AT COMPACTOR CLOSET, 3rd STORYOpen
Aug 21, 2026HPD C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH AT COMPACTOR CLOSET DOOR AT PUBLIC HALL, 1st STORYOpen
Aug 21, 2026HPD A§27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMAOpen
Aug 21, 2026HPD B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AND ASSEMBLIES AT COMPACTOR CLOSET DOOR AT PUBLIC HALL, 1st STORYOpen
Jul 22, 2026HPD B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 6F, 6th STORY, 3rd APARTMENT FROM SOUTH AT WESTOpen
Jul 22, 2026HPD CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6F, 6th STORY, 3rd APARTMENT FROM SOUTH AT WESTOpen
Jul 1, 2026ECBElevators: ELEVATOR WAS PREVIOUSLY ISSUED AN RTS CLASS 1 ON JUNE 15, 2026. UPON REINSPECTION, THE ELEVATOR WAS FOUND TO REMAIN OUT OF SERVICE, AND THE PREVIOUSLY CITED HAZARDOUS CONDITION HAD NOT BEEN CORRECTED. THE CONTIOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 28, 2026, 6:58 PM ET. BBL 2028500060.

Look up another building