Bronx · Block 2890 · Lot 15 · 10457

1756 Anthony Avenue

2 floors · 2 apartments · 3,672 sq ft · built 1901 · class B2 · owner of record: 1758 Anthony Ave Llc

11open violations
$77,500ECB/OATH penalties owed
0HPD class C (immediately hazardous)
309dto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 309 days
Required only if the owner doesn't live there

Open violations

ECB / OATH (6) · $77,500 owed
IssuedViolationHearingBalance
Sep 23, 2026Construction CLASS - 2
DURING MY INSPECTION OF A CLOSED, FULL-DEMOLITION SITE. I OBSERVED EXPOSURE-ONE ROADWAY PLASTIC YODOK BARRIERS IN PLACE, NOT MAINTAINED AS PER 3301.1.3 MANUFACTURER SPECIFICATIONS: NOT LOCKED TOGETHER OR FILLED
#39559530H
Dec 4, 2026
PENDING
$1,250
Sep 10, 2026Construction CLASS - 1
WHILE PERFORMING A RE-INSPECTION. I COMPARED THE PREVIOUS PICTURES TAKEN ON 05/29/2026 WITH THE CURRENT SITE CONDITION AND FOUND THAT THE PERMIT HOLDER HAD FAILED TO COMPLY WITH THE PARTIAL STOP-WORK ORDER AND
#39559000K
Nov 20, 2026
PENDING
$10,000
May 29, 2026Construction CLASS - 1
AT TIME OF INSPECTION OBSERVED A 2-STORY HOUSE DEMOLISHED TO 1ST FLOOR. NO ROOF PROTECTION INSTALLED AT EXP4. GLASS NOT REMOVED. FENCE, PEDESTRIAN PROTECTION NOT SET UP AS PER PLANS. FAILURE TO SET UP THIS SAFE
#39554901P
Aug 7, 2026
DEFAULT
$25,000
May 29, 2026Construction CLASS - 1
AT TIME OF INSPECTION OBSERVED EXCAVATOR ON SITE. BUILDING DOWN TO 1ST FLOOR. UPON REQUESTING FOR DEMO DRAWINGS WAS PROVIDED A 24-PAGE SET FOR FULL HAND DEMO. NO ADDITIONAL MECHANICAL DRAWING WERE PROVIDED.
#39554900N
Aug 7, 2026
DEFAULT
$25,000
May 29, 2026Construction CLASS - 1
AT TIME OF INSPECTION OBSERVED A 2 STORY HOUSE DOWN TO 1 STORY. 2ND FLOOR DEMOLISHED USING MECHANICAL EQUIPMENT. UPON RESEARCHING DOB RECORDS NO MECHANICAL DEMO PERMIT LOCATED. STOP ALL DEMO OPERATIONS - ONLY A
#39554789Y
Aug 7, 2026
DEFAULT
$6,250
Apr 3, 2025Construction CLASS - 1
FAILURE TO OBEY A VACATE ORDER FROM THE COMMISSIONER PER 28-207.4. NOTED: AT TIME OF INSPECTION - A MALE OCCUPANT WAS OBSERVED RESIDING AT 2ND FLR OF BUILDING: CONTRARY TO FULL VACATE ORDER 14/2024 ISSUED 01/29
#39143839R
Jun 11, 2027
PENDING
$10,000
DOB (6)
IssuedViolationStatus
Aug 22, 2025IMMEDIATE EMERGENCY
SEAL ALL ACCESSIBLE GROUND FLOOR DOORS AND WINDOWS AROUND THE ENTIRE PERIMETER OF THE BUILDING TO PREVENT UNAUTHORIZED ACCESS TO THE BUILD ING
#19489
DOB VIOLATION - ACTIVE
May 8, 2025CONSTRUCTION
UNLAWFUL ACTS. FAIL TO COMPLY WITH COMMISSIONER'S ORDER 012924CCER01JK ISSUED ON 1/2/2024. UP TO TODAY'S DATE, NO PERMITS HAVE BEEN OBTAINED TO REPAIR STRUCTURALLY COMPROMISED RETAINING WALL.REMEDY:IMMEDIATELY COMPLY W/COMMISSIONER'S ORDER 012924CCER01JK ISSUED 1/29/2024. RW UNIT 280 BROADWAY, 4TH F
#RW20503BH
DOB VIOLATION - ACTIVE
Jan 29, 2024CONSTRUCTION
STRUCTURE RENDERD NON COMPLIANT. RETAINING WALL @ EXPOSURE 3 HAS COLLA PSED IN ADDITION TO THE REAR YAD WITH REMINING EARTH SLOPE LEFT UNSTAB LE WITH POTENTIAL OF FURTHER COLLAPSE. OWNER HAS BEEN DIRECTED TO HIRE A LICNESED ENGINEER & SUBMIT AN ASSESMENT TO DOB CITING STRUCTURAL ST ABILITY OF THE BU
#CER01JK
DOB VIOLATION - ACTIVE
Jan 10, 2024CONSTRUCTION
STRUCTURE RENDERED NON-COMPLAINT. AT TIME OF INSPECTION DAMAGE OBSERVED TO HAVE BEEN SUSTAINED IN REAR YARD DUE TO RETAINING WALL COLLAPSED.
#24-00084
DOB VIOLATION - ACTIVE
Jan 10, 2024CONSTRUCTION
RETAINING WALL BETWEEN ANTHONY AVE AND CARTER AVE APPROXIMATELY OVER 150'-0" COLLAPSED. SECTION OF RETAINING WALL COLLAPSED ONTO CAR REPAIR SHOP AND DAMAGED REAR ROOF & WALL.
#24-00085
DOB VIOLATION - ACTIVE
Nov 20, 2020CONSTRUCTION
FTM:RETAIN WALL @REAR PROP LINE OF A 2 STY+BSMT WOOD FRAME RESID BLDG RETAIN WALL STATE OF DISRPR,BULG&THERE IS POTENT OF COLLAPSE RENDERING REAR YARD UNSAFE TO OCCUPY.OWNER TO IMMED VACATE REAR YARD TILL CONDNS SAFE.ENGAGE NYS PE TO EVAL WALL&PREP MONITOR PROG,SUBMT SIGN&SEAL REPT BY 12/15/2020.REP
#FEU20506XC
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Sep 23, 2026ECBConstruction: DURING MY INSPECTION OF A CLOSED, FULL-DEMOLITION SITE. I OBSERVED EXPOSURE-ONE ROADWAY PLASTIC YODOK BARRIERS IN PLACE, NOT MAINTAINED AS PER 3301.1.3 MANUFACTURER SPECIFICATIONS: NOT LOCKED TOGETHER OR FILLEDOpen
Sep 10, 2026ECBConstruction: WHILE PERFORMING A RE-INSPECTION. I COMPARED THE PREVIOUS PICTURES TAKEN ON 05/29/2026 WITH THE CURRENT SITE CONDITION AND FOUND THAT THE PERMIT HOLDER HAD FAILED TO COMPLY WITH THE PARTIAL STOP-WORK ORDER ANDOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 27, 2026, 10:57 PM ET. BBL 2028900015.