4 floors · 8 apartments · 5,196 sq ft · built 2021 · class C1 · owner of record: 1755 Brooklyn Ave Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 58 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 58 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 74 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 302 days | Registered through 2027-09-01 |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 18 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1154 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Dec 13, 2021 | Construction CLASS - 2 PEDESTRIAN PROTECTION ATOI OBSERVED PROPOSED 4STYNB ACTIVE JOBSITE W/EXTERIOR WORK INCOMPLETE@EXP1:WORK HASNT BEEN COMPLETE UNDERNEATH ALL BALCONIES@2FL&ABOVE,MEANWHILE NO SWS OR ROAD CLOSURE OBSERVED TO PROTEC #35632876H | Jul 20, 2022 IN VIOLATION | $2,400 |
| Jul 7, 2021 | Construction CLASS - 2 BC1704-1.1 FAILURE TO FILE SPC INSP STATEMENT.NOTE ATOI I OBSERVED COLDFORM STEEL NB IN PLACE W/LAST INSP 3/9/20&NOT ONSITE.COMPLY W/CODE-UPDATE INSP. #35575924P | Jun 29, 2022 IN VIOLATION | $625 |
| Jul 7, 2021 | Construction CLASS - 1 3314.1 PARTIAL SW FOR SUPPORTED SCF NOTE ATOI I OBSERVED SUPPORTED SCFIN PLACE IN HAZARDOUS CONDITION 1)GUARDRAILS MISSING 2)PLATFORMS NOT FULLY PLANKED 3)PLANKS NOT TIED DOWN.COMPLY W/CODE-WORK ALLOWED TO MAKE #35575923N | Jun 29, 2022 IN VIOLATION | $2,500 |
| Feb 16, 2021 | Construction CLASS - 2 FAILURE TO SAFEGUARD ALL PERSONS&PROPERTY AFFECTED BY CONST OPERATIONS@TIME OF MY INSP OF 4STYNB JOBSITE@1FL LEVEL,I OBSERVED MESSY OHP@EXP2&4.STOP ALL CONST ACTIVITIES 5ST FROM EXP2&4.REMOVE OHP MAECORON CEO T #35544003Z | Nov 19, 2021 IN VIOLATION | $5,000 |
| Feb 16, 2021 | Construction CLASS - 1 28-401.4 ILLEGALLY ENGAGING IN ANY BIZ OR OCCUPATION W/O REQUIRED LICENSE OR OTHER AUTHORIZATION NOTE:@TIME OF MY INSP OF 4STYNB JOBSITE,@1FL LEVEL I OBSERVED ON FURTHER INSP FROM BIS THAT GC LICENSE EXPIRED ON #35544002R | Nov 19, 2021 IN VIOLATION | $5,000 |
| Dec 1, 2020 | Construction CLASS - 2 NO WASHOUT BOX OR SAFETY MEASURES PREVENTING SEWAGE.NOTE:@TIME OF ENTRY OF INSPECTION OF PROPOSED 4STORY RESIDENTIAL BLDG,W/ CONCRETE OPERATIONS IN PROGRESS,I OBSERVED @EXP1 CONCRETE TRUCKS SET UP W/ OVERHEAD P #35508338M | Oct 15, 2021 IN VIOLATION | $2,500 |
| Dec 1, 2020 | Construction CLASS - 1 FAILURE TO SAFEGUARD.NOTE:@TIME OF INSPECITON OF 4STORY PROPOSED RESIDENTIAL BLDG,I OBSERVED CONCRETE POUR FOR FOUNDATION WALL @EXP4 IN PROGRESS WHEREAS ADJACENT PROPERTY (1761 BKLYN AVE) WALKWAY WAS UNDERMINED #35508335R | Oct 15, 2021 IN VIOLATION | $5,000 |
| Dec 1, 2020 | Construction CLASS - 1 FAILURE TO PROTECT PUBLIC SIDEWALKS & WALKWAYS.NOTE:@TIME OF INSPECTION OF 4STORY PROPOSED RESIDENTIAL BLDG W/ CONCRETE POURING OPERATIONS UNDERWAY,I OBSERVED OVERHEAD CONCRETE PUMPING @EXP1 FROM ROADWAY ONTO S #35508337K | Oct 15, 2021 IN VIOLATION | $10,000 |
| Dec 1, 2020 | Construction CLASS - 1 BC3307.7.1.FENCE AS REQUIRED.NOTE:@TIME OF INSPECTION OF A PROPOSED 4STORY RESIDENTIAL BLDG W/ CONCRETE OPERATIONS IN PROGRESS,I OBSERVED @EXP4 THERE WAS APPROX 25 LINEAR FEET OF JOBSITE FENCE REMOVED/MISSING A #35508339Y | Oct 15, 2021 IN VIOLATION | $2,500 |
| Dec 1, 2020 | Construction CLASS - 1 WARNING SIGNS,BARRICADES MISSING.NOTE:@TIME OF INSPECTION OF PROPOSED 4STORY RESIDENTIAL BLDG W/ CONCRETE OPERATIONS IN PROGRESS,I OBSERVED @EXP1,2 CONCRETE TRUCKS W/ 1 TRUCK PERFORMING OVERHEAD PUMPING STATION #35508340L | Oct 15, 2021 IN VIOLATION | $2,500 |
| Oct 22, 2020 | Construction CLASS - 2 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS.AT TIME OF INSPECTION OBSERVED FOUNDATION WORK DONE CONTRARY TO APPROVED PLANS AT EXPOSURE#3 AND EXPOSURE#4 AT THE SUBJECT PRE #35501527J | Jul 16, 2021 IN VIOLATION | $625 |
| Jan 14, 2020 | Construction CLASS - 1 SEC. 3301.2 FAILURE TO MAINTAIN ADEQUATE MEANS OF INGRESS/EGRESS. AT TIME OF INSPECTION OF A 2 STY FULL DEMO I OBSERVED JOB SITE ENTRANCE DOOR AT JOB SITE FENCE EXP#1 OBSTRUCTED BY EXISTING BLDG FENCE DOOR DOES #35467382L | Mar 22, 2021 IN VIOLATION | $2,500 |
| Jan 14, 2020 | Construction CLASS - 1 FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING AT TIME OF INSPECTION OF A 2STY FULL DEMO I OBSERVED HOUSEKEEPING NOT MAINTAINED LARGE AMOUNT DEBRIS ACCUMULATED AT 2ND STY,BACK YARD & AT EXP#4 SIDE YARD THAT POSE A #35467381J | Mar 22, 2021 IN VIOLATION | $2,500 |
| Jan 11, 2020 | Construction CLASS - 1 BC3309.10=NO OVERHEAD PROTECTION (ADJACENT PROPERTY EXPOSURE 32) AT THE TIME OF INSPECTION I OBSERVED PROPOSED DEMOLITION OF A 2 STORY BUILDING WITH NO WORK ACTIVITY PRESENT I ALSO OBSERVED CONTRACTOR FAILED TO #35463471P | Apr 22, 2021 IN VIOLATION | $2,500 |