Bronx · Block 4226 · Lot 6 · 10461

1740 Eastchester Road

5 floors · 172,268 sq ft · built 1977 · class I1 · owner of record: Calvary Hospital Inc.

1open violations
$2,500ECB/OATH penalties owed
0HPD class C (immediately hazardous)
48dto Energy audit and retro-commissioning (2026)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 48 days
Keep the report on file (not filed with DOB)
Energy audit and retro-commissioning (2026) Likely applies
Local Law 87 · Calendar year 2026
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 4226). Agency page

Dec 31, 2026
in 48 days
Due this year
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-10-02 (Accepted). Agency page

Dec 31, 2026
in 48 days
2 of 2 without an accepted 2026 report yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 172,268 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 169 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 169 days
Annual filing
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 413 days
Next cycle year 2027

Open violations

ECB / OATH (1) · $2,500 owed
IssuedViolationHearingBalance
Jul 28, 2026Construction CLASS - 1
AT THE TIME OF INSPECTION OF A 7-STORY EXITING BUILDING UNDER FACADES OPERATION, I OBSERVED WORKERS USING SUSPENDED SCAFFOLDING FOR PARAPET WALL OPERATION, UPON REQUESTING THE LICENSE RIGGING FOREMAN DESIGNATED
#39557141P
Mar 22, 2027
$2,500
DOB (0)

None open.

DOB NOW Safety (1)
IssuedViolationStatus
Jan 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle D (premises is in Community District 11)
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Jul 28, 2026ECBConstruction: AT THE TIME OF INSPECTION OF A 7-STORY EXITING BUILDING UNDER FACADES OPERATION, I OBSERVED WORKERS USING SUSPENDED SCAFFOLDING FOR PARAPET WALL OPERATION, UPON REQUESTING THE LICENSE RIGGING FOREMAN DESIGNATEDClosed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 13, 2026, 5:52 PM ET. BBL 2042260006.

Look up another building