Bronx · Block 2930 · Lot 72 · 10457

1729 Fulton Avenue

5 floors · 15 apartments · 12,455 sq ft · built 1909 · class C1 · owner of record: Crotona Park West Housing Development

14open violations
$8,750ECB/OATH penalties owed
3HPD class C (immediately hazardous)
58dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 58 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 58 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 74 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 302 days
Registered through 2027-09-01
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 789 days
Next cycle year 2028
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-01-16 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (4) · $8,750 owed
IssuedViolationHearingBalance
Apr 1, 2026Construction CLASS - 1
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. OBSERVED AT THE FRONT (EXP 1), THE FIRE-ESCAPE PLATFORMS ARE OBSTRUCTED BY AC UNITS ON THE 2ND FLOOR (RIGHT SIDE) AND 4TH FLOOR (LEFT SIDE) AS WELL AS THE REAR (
#39182881M
Nov 27, 2026
PENDING
$2,500
Apr 1, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER FOR SUMMONS 39156057P. OBSERVED AT REAR YARD (EXP 3) RETAINING WALL IS IN A STATE OF DISREPAIR WITH CRACKS, HOLES, BULGING, AND MISSING MORTAR JOINTS AND ST
#39182833H
Nov 27, 2026
PENDING
$6,250
Aug 5, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT TIME OF INSPECTION BACK SIDE RETAINING WALL, RUNNING AND STEP CRACKS, OPEN HOLE, LOOSE MORTAR AND BULGING, CREATING UNSAFE CONDITIONS OF POTENTIAL COLLA
#39156057P
May 11, 2026
IN VIOLATION
$0
Apr 25, 2024Construction CLASS - 2
AT TIME OF INSPECTION OBSERVED RETAINING WALL ON REAR YARD INSTATE OF DISREPAIR CONDITIONS WITH HORIZONTAL & STEP CRACKS ON RUBBLE STONES AND MISSING PIECES / HOLES THROUGHOUT., MAINTAIN EXTERIOR BUILDING WALL
#39112629R
Jul 5, 2024
IN VIOLATION
$0
DOB (2)
IssuedViolationStatus
Aug 8, 2025CONSTRUCTION
FAILURE TO MAINTAIN RETAINING WALL IN A SAFE CONDITION. AT THE TIME OF INSPECTION, WE NOTED THAT THE R.W. LOCATED AT THE REAR OF THE PROPERTY IS IN A STATE OF DISREPAIR AS WELL AS SIGNS OF BULGING IN SOME AREAS. REMEDY:IMMEDIATELY RETAIN A LICENSED STRUCTURAL ENGINEER PRODUCE AN ENGINEER REPOAR TO A
#RW20302BH
DOB VIOLATION - ACTIVE
Aug 5, 2025CONSTRUCTION
REQUEST A ENGINEERS REPORT DUE TO EXPOSURE 3(BACK)RETAINING WALL, CRACK, HOLES AND BULGING AREAS, AN ENGINEERING REPORT IS REQUIRED TO ASSESS AND RECTIFY THE DAMAGED CONDITIONS.
#25-01881
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
HPD (7) · C 3 · B 2 · A 2
IssuedClassViolationCorrect by
Oct 16, 2026A§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING HAND RAIL AT BUILDING ENTRANCE , 1st STORYJan 19, 2027
Sep 8, 2026A§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORYDec 12, 2026
May 15, 2026CApt 1A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER WINDOW SASH COUNTER BALANCE AT FIRE ESCAPE WINDOW IN THE 4th ROOM FROM EAST AT SOUTH LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTMay 21, 2026
Oct 24, 2025CApt 1A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTNov 19, 2025
Jun 4, 2025BApt 5A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ.FT AT CEILING IN THE BATHROOM LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 17670824 ISSUED 03-FEB-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017Jul 9, 2025
Dec 24, 2024BApt 5A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE KITCHEN LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM SOUTH AT WESTJan 28, 2025
Dec 24, 2024CApt 5A · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 1, WG TO REPLACE = 0, WG TO REPAIR = 0 IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5th STORY, 1st APARJan 19, 2025

Issued in the last 120 days

DateSourceWhatNow
Oct 16, 2026HPD A§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING HAND RAIL AT BUILDING ENTRANCE , 1st STORYOpen
Sep 8, 2026HPD A§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORYOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 3, 2026, 9:38 AM ET. BBL 2029300072.

Look up another building