3 floors · 3 apartments · 3,150 sq ft · built 1901 · class C0 · owner of record: Bailey, Samantha
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 61 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 61 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 77 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 305 days | Registered through 2027-09-01 |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 426 days | Next cycle year 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Mar 1, 1997 | Construction Non-Hazardous FAILURE TO MAINTAIN BUILDING DEFECT IS 1ST TO 2ND FLOOR STAIRS STRINGERS ARE DEFECTIVE MAKING STARS UNSTABLE. REMEDY: MAKE ALL NECESSARY REPAIRS IMMEDIATELY. #34139889L | Jul 11, 1997 WRITTEN OFF | $0 |
| Dec 26, 1996 | Construction Hazardous FAILUR ETO MAINTAIN FRIST FLOOR BATHROOM HAS LARGE CRACKS AND I SIN DANGER OF COLLASPING REMEDY MAKE SAFE IMMEDIATELY OBTAIN NECESSARY PERMITS MAINTAIN BUILDING #34139881R | Mar 28, 1997 WRITTEN OFF | $0 |
| Dec 17, 1996 | Construction Hazardous FAILUR ETO MAITAIN EXTERIOR BUILDING WALL DEFECT IS EXTERIOR CONCRETE STAIRS & STEP BROKEN DEFECTIVE AND PULLING AWAY 2-CONCRETE STEP HAS COLLAPSED AT 2 FRONT TOP STEP REMEDY MAKE ALL REPAIRS NECESSARY IN A SAF #34145350Z | Feb 21, 1997 WRITTEN OFF | $0 |
| Dec 14, 1996 | Construction Hazardous FAILURE TO MAINTAIN EXTERIOR BLDG WALL.DEFECT IS FRONT MASONARY STOOPIS CRACKED AND DEFECTIVE AT VARIOUS LOCATIONS WITH LOOSE METAL HARD RAILINGS, AND MISSING SECTION OF STAIR TREAD.REMEDY:MAKE ALL NECESSARY S #34142349H | Feb 14, 1997 WRITTEN OFF | $0 |
| Dec 14, 1996 | Construction Non-Hazardous FAILURE TO MAINTAIN.DEFECT IS-PUBLIC HALL STAIRS LEADING FROM 1ST TO 2ND STORY IS PULLING AWAY,LOOSE,AND DEFECTIVE.REMEDY:MAKE ALL NECESSARYSAFE AND LAWFUL REPAIRS IMMEDIATELY. #34142350P | Feb 14, 1997 WRITTEN OFF | $0 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Jan 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle D (premises is in Community District 11) | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Oct 2, 2017 | B | Apt 3FL · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 3FL, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Nov 6, 2017 |
| Oct 2, 2017 | B | Apt 3FL · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 3FL, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Nov 6, 2017 |
| Oct 2, 2017 | A | Apt 3FL · § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT SINK WASTELINE IN THE KITCHEN LOCATED AT APT 3FL, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 5, 2018 |
| Oct 2, 2017 | B | Apt 3FL · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES LOCATED AT APT 3FL, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Nov 6, 2017 |
| Oct 2, 2017 | A | Apt 3FL · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 2nd ROOM FROM EAST, THE 3rd ROOM FROM EAST, THE KITCHEN , THE 5th ROOM FROM EAST, THE BATHROOM LOCATED AT APT 3FL, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 5, 2018 |
| Sep 1, 2009 | A | SECTION 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION WOOD DECK ERECTED AT REAR YARD. | Dec 5, 2009 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 31, 2026, 10:14 PM ET. BBL 2040330014.