5 floors · 18 apartments · 8,595 sq ft · built 1925 · class C7 · owner of record: Dovero 2 Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 67 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 67 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 67 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-12-19 (Accepted). Agency page | Dec 31, 2026 in 67 days | 1 of 1 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 83 days | Annual |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 11, 2026 | Unknown CLASS - 1 I OBSERVED IN IN BASEMENT UNSAFE UNSUITABLE ELECTRICAL CONDITION, BREAKER PANELS COVERS MISSING LEAVING ALL LIVE WIRES EXPOSED AND SUBJECT TO ELECTROCUTION., COMPLY WITH EC; FIX ALL CONDITIONS ACCORDING TO NEC #39195743R | Sep 17, 2026 DEFAULT | $1,630 |
| Jul 11, 2026 | Unknown CLASS - 1 I OBSERVED IN APT 3FS UNSAFE UNSUITABLE ELECTRICAL CONDITION,ENTIRE APARTMENT BEEN FEED WITH AND SINGLE PHASE 120V 20 AMP CIRCUIT (12 AWG) SINGLE WIRE IS DOUBLE LUG AT BREAKER PANEL ALSO MISSING GFCI PROTECTION #39195741N | Jan 28, 2027 PENDING | $1,600 |
| Jul 11, 2026 | Unknown CLASS - 2 I OBSERVED IN APT 3FS INSTALLATION OF FEEDER CONDUCTORS WITHOUT AN ELECTRICAL PERMIT ON FILE., OBTAIN PERMIT; OBTAIN ELECTRICAL PERMIT #39195742P | Jan 28, 2027 PENDING | $1,250 |
| Apr 29, 2026 | Construction CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EGRESS; AT TIME OF INSPECTION, FIRE ESCAPE DROP LADDER AT EXPOSURE 1 REMAINS OBSTRUCTED BY METAL/FABRIC AWNING AND OUTDOOR SEATING WITH TABLES AND CHAIRS BENEATH. REMOVE ALL OBST #39186475P | Feb 4, 2027 PENDING | $6,250 |
| Apr 29, 2026 | Construction CLASS - 1 NO CERTIFICATE OF CORRECTION ON FILE AS PER COMMISSIONER'S REQUEST FOR CLASS 1 WORK-WITHOUT-PERMIT VIOLATION #35688116H ISSUED 12/26/2024 FOR ERECTED SYSTEM OF METAL AND FABRIC, PARTITION WALLS, WINDOWS, AND CE #39186469Z | Feb 4, 2027 PENDING | $2,500 |
| Apr 29, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION, FIRE ESCAPE PATHWAYS OBSTRUCTED WITH WINDOW A/C UNITS AT THE 2ND AND 5TH STORY., REMOVE OBSTRUCTION #39186513R | Jul 9, 2026 DEFAULT | $6,250 |
| May 13, 2025 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER: FAILURE TO PROVIDE REQUIRED NUMBER OF MEANS OF EGRESS FOR EVERY FLOOR AS PER BC 1008.1(2008 CODE); 27-366; BC 1021.1(2014 CODE); BC 1006.3(2022 CODE) FOR #35690577N | May 10, 2027 | $6,250 |
| May 13, 2025 | Quality of Life CLASS - 1 DWELLING CONVERTED, MAINTAINED OR OCCUPIED WITH 3 OR MORE ADDITIONAL DWELLING UNITS THAN LEGALLY AUTHORIZED BY DEPARTMENT OF BUILDINGS RECORDS. ILLEGAL OCCUPANCY NOTED: APARTMENT 3RN/3RS AT 3RD FLOOR LEVEL HAS #35690449Z | May 10, 2027 | $60,000 |
| May 13, 2025 | Quality of Life CLASS - 1 DWELLING CONVERTED, MAINTAINED OR OCCUPIED WITH 3 OR MORE ADDITIONAL DWELLING UNITS THAN LEGALLY AUTHORIZED BY DEPARTMENT OF BUILDINGS RECORDS. ILLEGAL OCCUPANCY NOTED: APARTMENT 3RN/3RS AT 3RD FLOOR LEVEL HAS #35690575J | May 10, 2027 | $60,000 |
| May 13, 2025 | Construction CLASS - 1 BC 907.2.8. FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. FAILURE TO PROVIDE A FIRE ALARM SYSTEM(CLASS J) FOR SRO'S AT UNIT 3RN/3RS ON 3RD FLOOR. PREVIOUS ECB VIOLATION #35681294Z. REMEDY: DISCONTINU #35690579R | May 10, 2027 | $6,250 |
| May 13, 2025 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. LACK OF A SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRED FOR BC 903.2; 27-954 FOR SRO'S AT UNIT 3RN/3RS ON 3RD FLOOR. PREVIOUS ECB VIOLATION #35681293R. R #35690578P | May 10, 2027 | $6,250 |
| May 13, 2025 | Quality of Life CLASS - 1 DWELLING CONVERTED, MAINTAINED OR OCCUPIED WITH 3 OR MORE ADDITIONAL DWELLING UNITS THAN LEGALLY AUTHORIZED BY DEPARTMENT OF BUILDINGS RECORDS. ILLEGAL OCCUPANCY NOTED: APARTMENT 3RN/3RS AT 3RD FLOOR LEVEL HAS #35690576L | May 10, 2027 | $60,000 |
| May 13, 2025 | Construction CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTED: AT THE TIME OFINSPECTION OBSERVED BEDROOM CREATED WITH DOOR AND LOCK, BED, OTHER PERSONAL ITEMS. OBSTRUCTING FREE ACCESS TO EMERGENCY ESCAPE STAIRS TO REA #35690581X | May 10, 2027 | $1,250 |
| Dec 26, 2024 | Construction CLASS - 1 WORK WITHOUT A PERMIT. WORK NOTED AT THE TIME OF INSPECTION HAVING A SYTEM OF METAL AND FABRIC FRAMING STRUCTURE WITH PARTITION WALLS, WINDOW, AND CEILING CREATED AT SIDEWALK EXPOSURE 1 ATTACHED TO THE BUILDING #35688116H | Dec 14, 2026 PENDING | $2,500 |
| Dec 26, 2024 | Construction CLASS - 1 BC 1029.5.1. FAILURE TO COMPLY WITH REQUIRED ACCESSIBLE MEANS OF EGRESS AT EMERGENY FIRE ESCAPE AND RESCUE. NOTED AT EXPOSURE 1 DROP LADDERSARE OBSTRUCTED BY OUTDOOR SEATING ARRANGEMENT HAVING TABLES AND CHAIRS #35688117J | Dec 14, 2026 PENDING | $2,500 |
| Aug 27, 2024 | Construction CLASS - 1 BC 907.2.8. FAILURE TO PROVIDE FIRE ALRM SYSTEM CLASS "CLASS J" FOR TRANSIENT USE AT APT 3RN-3RS. REMEDY: DISCONTINUE ILLEGAL OCCUPANCY. #35681294Z | Feb 1, 2027 | $2,500 |
| Aug 27, 2024 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: LACK OF REQUIRED NUMBER OF MEANS OF EGRESS FOR EVERY FLOOR AS PER BC 1018.1(2008 CODE); 27-366; BC 1021.1(2014 CODE); BC 1006.3(2022 CODE) FOR TRANSIENT US #35681292P | Feb 1, 2027 | $2,500 |
| Aug 27, 2024 | Quality of Life CLASS - 2 PERMANENT DWELLING USED/CONVERTED FOR OTHERS THAN PERMANENT-RESIDENTIAL PURPOSES: DEPT OF BUILDINGS RECORDS INDICATES PREMISES TO BE LEGALLYAPPROVED AS CLASS 'A" MULTIPLE DWELLING. ILLEGAL OCCUPANCY NOTED: APT #35681291N | Feb 1, 2027 | $2,500 |
| Aug 27, 2024 | Construction CLASS - 2 WORK WITHOUT PERMIT. NOTED IN APARTMENT 2RS ON THE SECOND FLOOR ERECTED FULL HEIGHT PARTITION WALL TO CONCERT STUDIO APARTMENT INTO 1 BEDROOM APARTMENT. REMEDY: OBTAIN ALL PERMITS. #35681295K | Feb 1, 2027 PENDING | $1,250 |
| Aug 27, 2024 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: LACK OF A SYSTEM OF AUTOMATIC SPRINKLER WHERE IS REQUIRED PER BC 903.2 AND 27-954, FOR TRANSIENT USE AT APT 3RN-3RS. REMEDY: DISCONTINUE ILLEGAL OCCUPANCY. #35681293R | Feb 1, 2027 | $1,250 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Oct 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle C (premises is in Community District 8) | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jun 15, 2021 | A | § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION METAL CORNICE AT ROOF BUILDING FRONT | Sep 18, 2021 |
| May 3, 2019 | B | § 27-2005 ADM CODE PROVIDE APPROVED METAL SCREEN BELOW BULKHEAD SKYLIGHT AT PUBLIC HALL | Jun 7, 2019 |
| Sep 26, 2017 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CORNICE AT ROOF | Oct 31, 2017 |
| Sep 26, 2017 | A | § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION CORNICE AT ROOF | Dec 30, 2017 |
| Aug 28, 2017 | B | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE METAL CORNICE AT BUILDING FRONT AT ROOF AT FIRE ESCAPE, SECTION AT EAST | Oct 2, 2017 |
| Date | Source | What | Now |
|---|---|---|---|
| Jul 11, 2026 | ECB | Unknown: I OBSERVED IN IN BASEMENT UNSAFE UNSUITABLE ELECTRICAL CONDITION, BREAKER PANELS COVERS MISSING LEAVING ALL LIVE WIRES EXPOSED AND SUBJECT TO ELECTROCUTION., COMPLY WITH EC; FIX ALL CONDITIONS ACCORDING TO NEC | Open |
| Jul 11, 2026 | ECB | Unknown: I OBSERVED IN APT 3FS UNSAFE UNSUITABLE ELECTRICAL CONDITION,ENTIRE APARTMENT BEEN FEED WITH AND SINGLE PHASE 120V 20 AMP CIRCUIT (12 AWG) SINGLE WIRE IS DOUBLE LUG AT BREAKER PANEL ALSO MISSING GFCI PROTECTION | Open |
| Jul 11, 2026 | ECB | Unknown: I OBSERVED IN APT 3FS INSTALLATION OF FEEDER CONDUCTORS WITHOUT AN ELECTRICAL PERMIT ON FILE., OBTAIN PERMIT; OBTAIN ELECTRICAL PERMIT | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 25, 2026, 2:55 AM ET. BBL 1015350022.