4 floors · 10 apartments · 7,888 sq ft · built 2025 · class C7 · owner of record: 171 Montrose Avenue Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 47 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 63 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 778 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Apr 10, 2026 | Construction CLASS - 2 SITE CLOSED NO CONSTRUCTION ACTIVITY TAKING PLACE AT TIME OF INSPECTION AND NO WAY TO VERIFY IF VIOLATION#039550124L ISSUED ON 2/9/26 FOR NO GUARDRAILS ON SCAFFOLD AT EXPO#1 AND #3, WAS RESOLVED. RESPONDENT FAI #39552860Z | May 24, 2027 DEFAULT | $6,250 |
| Apr 9, 2026 | Construction CLASS - 2 SITE CLOSED NO CONSTRUCTION ACTIVITY TAKING PLACE AT TIME OF INSPECTION AND NO WAY TO VERIFY IF VIOLATION#039550161K ISSUED ON 2/9/26 FOR C.S FAILING TO PERFORM DUTIES WAS RESOLVED. RESPONDENT FAILED TO COMPLY #39552832L | May 24, 2027 DEFAULT | $6,250 |
| Apr 9, 2026 | Construction CLASS - 2 SITE CLOSED NO CONSTRUCTION ACTIVITY TAKING PLACE AT TIME OF INSPECTION AND NO WAY TO VERIFY IF VIOLATION#039550128Z ISSUED ON 2/9/26 FOR FAILING TO MAINTAIN DOCUMENTS ON SITE, WAS RESOLVED . RESPONDENT FAILED #39552834P | May 24, 2027 DEFAULT | $6,250 |
| Apr 9, 2026 | Construction CLASS - 2 SITE CLOSED NO CONSTRUCTION ACTIVITY TAKING PLACE AT TIME OF INSPECTION AND NO WAY TO VERIFY IF VIOLATION#039550125N ISSUED ON 2/9/26 FOR MISSING TOEBOARDS ON PIPE SCAFFOLD AT EXPO#1AND#3, WAS EVER RESOLVED. RE #39552836Z | May 24, 2027 DEFAULT | $3,125 |
| Mar 30, 2026 | Cranes and Derricks CLASS - 1 AT THE TIME OF MY INSPECTION OF A FOUR-STORY BUILDING WITH AN ACTIVE JOB SITE, A REVIEW OF DEPARTMENT RECORDS REVEALED THE GENERAL CONTRACTOR'S WORKERS' COMPENSATION INSURANCE EXPIRED ON MARCH 20, 2026. STOP AL #39552422Z | May 24, 2027 DEFAULT | $12,500 |
| Mar 30, 2026 | Construction CLASS - 2 AT THE TIME OF MY INSPECTION OF 4 STORY BUILDING ACTIVE JOB SITE UPON REVIEWING THE DEPARTMENT RECORD IT WAS FOUND GC PERMIT B00941918-I1-GC HAS BEEN EXPIRED MARCH 20TH 2026 STOP ALL WORK ENTIRE JOB SITE OB #39552420P | May 24, 2027 DEFAULT | $3,125 |
| Mar 30, 2026 | Unknown CLASS - 2 4-STORY BUILDING WITH AN ACTIVE JOB SITE, COPING STONE WORK WAS IN PROGRESS AT EXP #3 AND #4. A BENCH WAS LOCATED DIRECTLY BELOW THE WORK AREA AT THE ADJACENT PROPERTY WITH NO OVERHEAD PROTECTION IN PLACE, CREA #39552421R | May 24, 2027 DEFAULT | $10,000 |
| Feb 9, 2026 | Unknown CLASS - 2 UPON INSPECTION OF AN ACTIVE 4 STORY ALT CONSTRUCTION SITE AND REQUEST TO SEE WORKER BIENVENIDO ARISTY PALLANO'S SITE SAFETY TRAINING CARD (SST CARD) I WAS PRESENTED WITH A TRAINING CARD THAT ON FEB 1, 2023 WAS #39550159L | May 24, 2027 DEFAULT | $10,000 |
| Feb 9, 2026 | Construction CLASS - 2 SIDEWALK SHED INSTALLED AT EXPOS 1 CONTRARY TO CODE. 8FT MIN HEIGHT NOT MAINTAINED. PIPE SET BELOW 8FT ACROSS PATHWAY INFRONT OF ADJOINING PROPERTIES (3307.6.4.7) .VERTICAL MEMBERS INSTALLED WITHIN 18 INCHES FR #39550149H | May 24, 2027 DEFAULT | $5,000 |
| Feb 9, 2026 | Unknown CLASS - 2 MISCELLANEOUS VIOLATIONS. UPON INSPECTION OF AN ACTIVE 4 STORY ALT CONSTRUCTION SITE I OBSERVED UNFINISHED WORK ON ROOF AND NO PROTECTION PROVIDED FOR THE ADJOINING PROPERTY ROOF, SKYLIGHT AND MECHANICAL AT EXP #39550183L | May 24, 2027 DEFAULT | $5,000 |
| Feb 9, 2026 | Site Safety CLASS - 1 UPON INSPECTION I OBSERVED 17 VIOLATING AND POTENTIAL HAZARDOUS CONDITIONS THAT CAN LEAD TO (FIRE TO SITE AND ADJOINING PROPERTIES, WORKER FALL/DROP INJURIES/DEATH, EQUIPMENT COLLAPSE/FAIL, ADJOINING PROPERTY D #39550161K | May 25, 2027 DEFAULT | $12,500 |
| Feb 9, 2026 | Construction CLASS - 1 UPON INSPECTION OF AN ACTIVE 4 STORY ALT CONSTRUCTION SITE I OBSERVED PIPE SCAFFOLD FULLY INSTALLED AT EXPOS 1&3 APPROX. 54FT IN HEIGHT WITH NO TOE BOARDS INSTALLED AT PLANKED LEVELS CONTRARY TO CODE. STOP ALL #39550125N | Jan 14, 2027 | $5,000 |
| Feb 9, 2026 | Construction CLASS - 1 UPON INSPECTION OF AN ACTIVE 4 STORY ALT CONSTRUCTION SITE I OBSERVED PIPE SCAFFOLD FULLY INSTALLED AT EXPOS 1&3 APPROX. 54FT IN HEIGHT WITH NO GUARD RAILS INSTALLED AT PLANKED LEVELS CONTRARY TO CODE. STOP ALL #39550124L | Jan 14, 2027 | $5,000 |
| Feb 9, 2026 | Construction CLASS - 2 UPON INSPECTION OF AN ACTIVE 4 STORY ALT CONSTRUCTION SITE I OBSERVED PIPE SCAFFOLD FULLY INSTALLED AT EXPOS 1&3 APPROX. 54FT IN HEIGHT. UPON REQUEST TO SEE THE FOLLOWING DOCUMENTS TO BE KEPT ON SITE NON WAS PR #39550126P | May 15, 2026 IN VIOLATION | $1,250 |
| Feb 9, 2026 | Construction CLASS - 1 UPON INSPECTION OF AN ACTIVE 4 STORY ALT CONSTRUCTION SITE I OBSERVED PIPE SCAFFOLD INADEQUATELY INSTALLED AT EXPOSURE 1 APPROX. 54FT IN HEIGHT. UPON FULL REVIEW OF DOB RECORDS THERE WAS NOT PERMIT FOR THE INST #39550121X | May 15, 2026 IN VIOLATION | $5,000 |
| Feb 9, 2026 | Unknown CLASS - 2 UPON INSPECTION OF AN ACTIVE 4 STORY ALT CONSTRUCTION SITE I OBSERVED THE ADJOINING PROPERTY AT EXPOSURE 2 WITH INADEQUATE ROOF PROTECTION COVERAGE. ROOF NOT FULLY PROTECTED CONTRARY TO CODE 3309.10 PROTECTION #39550130H | May 15, 2026 IN VIOLATION | $2,500 |
| Feb 9, 2026 | Site Safety CLASS - 1 UPON INSPECTION OF AN ACTIVE 4 STORY ALT CONSTRUCTION SITE I OBSERVED A TEMP PLATFORM IN USE INSTALLED INSIDE THE ELEVATOR SHAFT. UPON REQUEST TO SEE DESIGN DRAWINGS FOR THE TEMP PLATFORM, NONE WAS PROVIDED AT #39550128Z | May 15, 2026 IN VIOLATION | $2,500 |
| Feb 9, 2026 | Unknown CLASS - 2 UPON INSPECTION OF AN ACTIVE 4 STORY ALT I OBSERVED PIPE SCAFFOLD INSTALLED IN AN UNSAFE MANNER AT EXPOS 1&3 CONTRARY TO CODE 3314.1. I OBSERVED MULTIPLE MISSING STACKING PINS, PLANKS NOT TIED DOWN AND SECURED #39550122H | Jan 14, 2027 | $2,500 |
| Feb 9, 2026 | Unknown CLASS - 2 UPON INSPECTION OF AN ACTIVE 4 STORY ALT CONSTRUCTION SITE I OBSERVED INADEQUATE AND MISSING FIRE EXTINGUISHERS ON ALL FLOORS. EXTINGUISHERS ON ALL FLOORS EXCEPT 1 WAS DISCHARGED. ALL EXTINGUISHERS WERE NOT INS #39550150P | May 24, 2027 DEFAULT | $1,562 |
| Feb 9, 2026 | Construction CLASS - 2 UPON INSPECTION I OBSERVED A SIDEWALK SHED INSTALLED AT EXPOSURE 1 WITH AN INCORRECT SIZE SIDEWALK SHED PROJECT INFO PANEL INSTALLED. INSTALLED. THE PROJECT INFO PANEL WAS APPROX. 2FTX3FT CONTRARY TO CODE 3301. #39550157H | May 24, 2027 DEFAULT | $3,125 |
| Feb 9, 2026 | Construction CLASS - 2 UPON INSPECTION AND REQUEST TO SEE THE FOLLOWING DOCUMENTS TO BE KEPT ON SITE FOR THE SIDEWALK SHED INSTALLED AT EXPOSURE 1 (APPROVED SIDEWALK SHED DRAWINGS, SHED DAILY INSPECTION LOG, SHED INSTALLATION LETTER #39550152Z | May 24, 2027 DEFAULT | $6,250 |
| Feb 9, 2026 | Unknown CLASS - 2 UPON INSPECTION OF AN ACTIVE 4 STORY ALT CONSTRUCTION SITE I OBSERVED 2 STAIRCASES WITH FRAMING AROUND THEM WITH GAPS LARGE ENOUGH FOR A PERSON TO FALL THROUGH AND NO GUARDRAILS PROVIDED TO PREVENT ANYONE FROM #39550160Z | May 24, 2027 DEFAULT | $5,000 |
| Feb 9, 2026 | Construction CLASS - 2 UPON INSPECTION I OBSERVED A FENCE INSTALLED AT EXPOSURE 1 NOT CONSTRUCTED OR MAINTAINED ACCORDING TO CODE. INSTALLED VIEWING PANEL WAS NOT 12X12 AND WAS NOT BLOCKED WITH NON-FRANGIBLE ACRYLIC PANELING OR EQUIV #39550147Y | May 24, 2027 DEFAULT | $2,500 |
| Sep 26, 2024 | Construction CLASS - 2 FAILURE TO MAINTAIN/DISPLAY ONSITE DOCUMENTS REQUIRED BY BC CHAPTER 33AT THE TIME OF INSPECTION OBSERVED FOUNDATION STAGE WORK IN PROGRESS ABOUT MORE THAN 80% OF FOUNDATION WERE INSTALLED EXIT 1 INSULATION WAS #35664666X | Jun 24, 2025 | $1,280 |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #11133 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #10059 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION #16034 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION #36198 | DOB VIOLATION - ACTIVE |
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION #17040 | DOB VIOLATION - ACTIVE |
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION #37437 | DOB VIOLATION - ACTIVE |
| Apr 25, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION #16398 | DOB VIOLATION - ACTIVE |
| Nov 8, 2019 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT #10682 | DOB VIOLATION - ACTIVE |
| Oct 1, 2015 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT #09653 | DOB VIOLATION - ACTIVE |
| Mar 3, 2015 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT #11601 | DOB VIOLATION - ACTIVE |
| May 15, 2014 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT #10462 | DOB VIOLATION - ACTIVE |
| Mar 1, 2013 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT #08677 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Sep 23, 2024 | Boiler LBLVIO Violation Issued-Failure To File 2023 External Low Pressure Inspection Report | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Apr 25, 2023 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2022 INSPECTION REPORT | Active |
| Nov 8, 2019 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT | Active |
| Oct 1, 2015 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT | Active |
| Mar 3, 2015 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT | Active |
| May 15, 2014 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT | Active |
| Mar 1, 2013 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT | Active |
None open.