3 floors · 3 apartments · 3,645 sq ft · built 2004 · class C0 · owner of record: 171 Beach 90 Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 62 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 62 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 78 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 306 days | Registered through 2027-09-01 |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 14 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 427 days | Next cycle year 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 3, 2024 | Construction CLASS - 3 FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. NOTED AT FRONT RIGHT SIDE OF BUILDING, OBSERVED RAIN LEADER PIPE HAS BECOME DETACHED FROM RAIN GUTTER AT ROOF., REPAIR AND OR REPLACE #39120768R | Oct 8, 2024 ADMIT/IN-VIO | $0 |
| Oct 5, 2023 | Construction CLASS - 3 FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. NOTED; AT FRONT LEADER PIPE DETACHED FROM GUTTER., REPAIR AND OR REPLACE #39096472K | Dec 12, 2023 DEFAULT | $0 |
| Feb 17, 2006 | Construction Non-Hazardous NOTED: NEW CONSTRUCTION-REAR SITE FENCE OPEN & IN DISREPAIR. REMEDY: REPAIR/REPLACE FENCE. #34509780N | Apr 4, 2006 IN VIOLATION | $0 |
| Feb 17, 2006 | Construction Non-Hazardous NOTED: PERMIT #401566319 NB ISSUED 6/7/05-EXPIRED 01-28-06-PERMIT RENEWAL NOT IN PROCESS. REMEDY: STOP ALL WORK, RENEW PERMIT, ADVISE CONSTRUCTION DIV PRIOR TO RECOMMENCING WORK FOR STOP WORK ORDER LIFT INSPECT #34509775Z | Apr 4, 2006 IN VIOLATION | $0 |
| Feb 17, 2006 | Construction Non-Hazardous NOTED: FAILURE TO POST CONTRACTOR SIGN AS REQUIRED BY ADMIN CODE-MISSING REQUIRED INFO. REMEDY: PROVIDE CONTRACTOR SIGN AS REQUIRED. #34509776K | Apr 4, 2006 IN VIOLATION | $0 |
| Oct 1, 2005 | Construction Non-Hazardous NOTED: FAILURE TO POST CONTRACTOR'S (311 ADVISORY, CONTRACTOR & OWNER INFO) SIGNS AS REQUIRED BY ADMIN CODE FOR NB 401566319 ISSUED 06/17/05EXPIRED 01/28/06. REMEDY: POST REQUIRED SIGNS AS PER ADMIN CODE. #34405717Y | Dec 13, 2005 WRITTEN OFF | $0 |
| Oct 1, 2005 | Site Safety Hazardous NOTED: JOB SITE FENCE DEFECTIVE,LEANING,OPEN & MISSING SECTIONS ALONG NEIGHBORING REAR YARD & FRONT SIDEWALK CREATING HAZARDOUS CONDITION. NB 401566319 EQ-FN ISSUED 06-07-05, EXPIRED 01-28-06. REMEDY: REPAIR #34405718X | May 21, 2013 IN VIOLATION | $0 |
| Oct 1, 2005 | Construction Hazardous NOTED: FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING THROUGHOUT SITE. CONSTRUCTION & COMBUSTIBLE MATERIALS IN FRONT & REAR YARDS & WITHIN STRUC-TURE (NO DEBRIS CONTAINERS OBSERVED). NB 401566319 ISSUED 06/07/05, EX #34405719H | May 21, 2013 IN VIOLATION | $0 |
| May 4, 2005 | Construction Hazardous FAILURE TO MAINTAIN JOB#401566319(EQ/FENCE)NOTED DEFECT:CONST FENCE PLYWOOD TYPE APPROX 8'H DEFECTIVE LOOSE/LEANING APPROX 16'L ONTO PUBLIC SIDEWALK MISSING SECTIONS ALL AROUND LEANING ONTO ADJACNET PROPERTIES #34479238Z | Jun 21, 2005 WRITTEN OFF | $0 |
| May 4, 2005 | Construction Non-Hazardous WORK WITHOUT A PERMIT: EXPIRED PERMIT. NOTED: CONST. FENCE APPROX 8'H ERECTED AROUND JOB SITE. PERMIT #401566319 EQ/FENCE, EXPIRED 12/31/04.REMEDY: RENEW PERMIT. #34479239K | Nov 22, 2011 IN VIOLATION | $0 |
| Apr 30, 2005 | Site Safety Hazardous NOTED:WOODEN CONSTRUCTION FENCE IN DISREPAIR WITH MISSING SECTIONS (OPEN SITE & UNGUARDED) LEANING & LOOSE SECTIONS AND FALLEN SECTIONS OBSTRUCTING SIDEWALK.PERMIT #401566319 EQ FN EXPIRED 12/31/04.REMEDY:REPAI #34468694Z | May 21, 2013 IN VIOLATION | $0 |
| Mar 21, 2005 | Construction Non-Hazardous WORK W/O PERMIT.EXPIRED PERMIT#401566319(EG/FENCE)EXPIRED ON 12/31/04.WORK NOTED:CONSTRUCTION FENCE APPROX. 8'H PLYWOOD TYPE WAS ERECTED ALL AROUND CONST. SITE APPROX. 200 IN TOTAL LENGTH AND PERMIT EXPIRED.REM #34471759H | Aug 30, 2005 WRITTEN OFF | $0 |
| Mar 21, 2005 | Construction Hazardous FILURE TO MAINTAIN.JOB#401566319.NOTED DEFECT:CONSTRUCTION FENCE APPROX. 8'H PLYWOOD TYPE,LOOSE/LEANING:APPROX.24'ONTO PUBLIC SIDE WALK @ WEST SIDE AND APPROX. 28' ONTO ADJACENT PROPERTY @ SOUTHSIDE.REMEDY:MAKE #34471760P | Aug 30, 2005 IN VIOLATION | $0 |
| Jun 9, 2004 | Construction Hazardous FAILURE TO PROTECT ADJOINING STRUCTURES DURING EXCAVATION OPERATIONS. EXCAVATION IN PROGRESS UNDER NB #401566319 & 401566300, EXCAVATED THREE FEET ONTO ADJOINING PROPERTY AT 167 B 90ST. DAMAGE TO SEWER PIPE AND #34437440R | Jul 27, 2004 WRITTEN OFF | $0 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Jan 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle D (premises is in Community District 14) | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| May 20, 2026 | B | Apt 2 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ.FT INSIDE BASE CABINET AT SINK IN THE KITCHEN LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 18580224 ISSUED 19-JAN-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIV | Jun 24, 2026 |
| Jan 20, 2026 | B | Apt 2 · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Feb 24, 2026 |
| Jan 20, 2026 | B | Apt 2 · § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE LINE AT SINK IN THE KITCHEN LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Feb 24, 2026 |
| Jan 20, 2026 | B | Apt 2 · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Feb 24, 2026 |
| Jan 20, 2026 | C | Apt 2 · § 27-2028, 2032 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FROM AN APPROVED CENTRAL HEATING SYSTEM, OR AN APPROVED SYSTEM OF GAS OR ELECTRICAL HEATING IN GOOD OPERATING CONDITION FOR THE DWELLING UNIT IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Jan 20, 2026 |
| Jan 20, 2026 | C | Apt 2 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Jan 20, 2026 |
| Jan 20, 2026 | C | Apt 2 · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Feb 3, 2026 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 30, 2026, 6:09 AM ET. BBL 4161330030.