4 floors · 8 apartments · 6,264 sq ft · built 1925 · class C1 · owner of record: 171 15 St, Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 66 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 66 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 82 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 310 days | Registered through 2027-09-01 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-14 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 23, 2025 | Construction CLASS - 1 SUMMONS ISSUED FOR FAILURE TO MAINTAIN DUE MULTIPLE CRACKS IN THE CONCRETE FACADE AT EXPOSURE #3 ALONG WITH SECTION OF FACADE BOWING AND PULLING AWAY FROM STRUCTURE AT EXPOSURE #3, REPAIR AND/REPLACE #39164666K | Sep 21, 2026 IN VIOLATION | $2,500 |
| Issued | Violation | Status |
|---|---|---|
| Oct 24, 2025 | CONSTRUCTION EMERGENCY WRK ORDR.THE EXP3 MASNRY WALL WAS BULGD OUT&CRACKD NEAR 2/3 CRNR FRM GRADE TO 2NDFL LVL.GAPS BTWN EXP3 1STFL WINDOW EXP3 CELLAR LINTELS PRTLLY DTACHD.EXP3 WALL STRCT CMPRMSD&AT RISK.OWNR TO IMMED RATIN NYSPE&DOB REG GC TO IMMED 1.E PE TO SUBMIT MEANS&METHDS FOR EXP3 WALLS TEMP STBLZTN/DEMO #FEU30601PN | DOB VIOLATION - ACTIVE |
| Oct 24, 2025 | CONSTRUCTION FAILURE TO MAINTAIN.EXP3 MASNRY WALL WAS BULGNG OUT&CRACKED/CMPRMSD@ 1STFL FRM GRADE TO 2NDFL LVL.EXP3WALL&REAR FIRE ESCPE CMRPMSD INT CRCKS@PARTITION WALLS&WALL/CEILNG FINISHES THRU-OUT,SPEC @ FRONT.OWNR TO RTAIN NYSPE TO EVAL ENT BLDG&PREPARE/FILE RPAIR DWGS W/DOB.PERM RPAIR BLDG UNDR PRMT STRTNG #FEU30602PN | DOB VIOLATION - ACTIVE |
| Oct 23, 2025 | CONSTRUCTION STRUCTURE RENDERED NON COMPLIANT DUE TO MULTIPLE CRACKS IN THE EXTERIOR FACADE AT EXPOSURE #3 ALONG WITH SECTIONS OF THE FACADE BOWING AND PULLING AWAY FROM THE STRUCTURE #25-02399 | DOB VIOLATION - ACTIVE |
| Mar 29, 2001 | CONSTRUCTION HAZARDOUS #07HD01 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 9, 2025 | B | Apt 1L · § 27-2005 HMC: REFIT DOOR IN THE ENTRANCE LOCATED AT APT 1L, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST | Oct 14, 2025 |
| Dec 3, 2020 | C | Apt 1L · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st RADIATOR FROM SOUTH AT WEST WALL IN THE KITCHEN LOCATED AT APT 1L, 1st STORY, 1st | Dec 27, 2020 |
| Aug 4, 2016 | B | Apt 1L · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 8, 2016 |
| Jan 22, 2013 | B | Apt 1L · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1L, 1st STORY, APARTMENT AT NORTH | Feb 26, 2013 |