Manhattan · Block 1551 · Lot 53 · 10128

1708 2 Avenue

5 floors · 12 apartments · 10,000 sq ft · built 1915 · class C7 · owner of record: Second Avenue Realty

21open violations
$0ECB/OATH penalties owed
4HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 68 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 68 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 68 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 84 days
Annual

Open violations

ECB / OATH (0)

None open.

DOB (9)
IssuedViolationStatus
Dec 11, 1997CONSTRUCTION

#B8GJ02
VIOLATION UNSERVED ECB-ACTIVE
Dec 11, 1997CONSTRUCTION

#B8GJ02
DOB VIOLATION - ACTIVE
Apr 16, 1996CONSTRUCTION

#08M01
DOB VIOLATION - ACTIVE
Apr 16, 1996CONSTRUCTION

#08M01
VIOLATION UNSERVED ECB-WORK WITHOUT PERMIT-ACTIVE
Jan 24, 1996CONSTRUCTION

#08M02
DOB VIOLATION - ACTIVE
Aug 8, 1994CONSTRUCTION

#08M03
DOB VIOLATION - ACTIVE
Jun 8, 1994CONSTRUCTION

#08M03
VIOLATION UNSERVED ECB-ACTIVE
Feb 25, 1993CONSTRUCTION

#08DB03
DOB VIOLATION - ACTIVE
Feb 25, 1993CONSTRUCTION

#08DB03
VIOLATION UNSERVED ECB-ACTIVE
DOB NOW Safety (0)

None open.

HPD (12) · C 4 · B 7 · A 1
IssuedClassViolationCorrect by
Mar 3, 2025BApt 5R · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 5R, 5th STORY, 1st APARTMENT FROM WEST AT NORTHApr 7, 2025
Mar 3, 2025BApt 5R · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 5R, 5th STORY, 1st APARTMENT FROM WEST AT NORTHApr 7, 2025
Aug 3, 2023BApt 4S · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECANICAL VENTILATION SYSTEM AT EAST WALL IN THE BATHROOM LOCATED AT APT 4S, 4th STORY, 1st APARTMENT FROM WEST AT NORTHSep 7, 2023
Aug 3, 2023AApt 4S · § 27-2059 ADM CODE DISCONTINUE USE OF INTERIOR ROOM FOR LIVING OR PROVIDE AN ALCOVE OPENING OF AT LEAST 32# SQ FT TO ROOM HAVING A WINDOW OPENING DIRECTLY TO STREET OR YARD IN THE 1st ROOM FROM EAST LOCATED AT APT 4S, 4th STORY, 1st APARTMENT FROM WEST AT NORTHNov 6, 2023
Aug 3, 2023BApt 4S · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 4S, 4th STORY, 1st APARTMENT FROM WEST AT NORTHSep 7, 2023
Aug 3, 2023BApt 4S · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 4S, 4th STORY, 1st APARTMENT FROM WEST AT NORTHSep 7, 2023
Aug 3, 2023CApt 4S · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER WINDOW SASH AT FIRE ESCAPE WINDOW IN THE 4th ROOM FROM EAST LOCATED AT APT 4S, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHAug 9, 2023
Aug 3, 2023CApt 4R · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER WINDOW SASH AT FIRE ESCAPE WINDOW IN THE 1st ROOM FROM NORTH LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM NORTH AT EASTAug 9, 2023
Aug 3, 2023BApt 5R · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONSISTING OF AIR CONDITIONER INSTALLED AT WINDOW LEADING TO FIRE ESCAPE IN THE 1st ROOM FROM NORTH LOCATED AT APT 5R, 5th STORY, 1st APARTMENT FROM NORTH AT EASTSep 7, 2023
May 8, 2019CApt 5N · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 5N, 5th STORY, 1st APARTMENT FROM WEST AT NORTHMay 16, 2019
May 3, 2019CApt 5N · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 5N, 5th STORY, 1st APARTMENT FROM WEST AT NORTHMay 11, 2019
Apr 25, 2019B§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FIRE CONBUSTABLE MATERIAL ON THE FLOOR AT ALL STORIES, PUBLIC HALLMay 30, 2019

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 24, 2026, 9:28 AM ET. BBL 1015510053.