Brooklyn · Block 5217 · Lot 7501 · 11226

1702 Newkirk Avenue

6.25 floors · 12 apartments · 10,951 sq ft · built 2018 · class R4 · owner of record: 1702 Newkirk Avenue Llc

0open violations
$21,875ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 61 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 61 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 77 days
Annual
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 14 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 426 days
Next cycle year 2027
Facade inspection report (Cycle 10B) Applies
Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. Agency page

Feb 21, 2028
in 478 days
No Cycle 10 report on record yet

Open violations

ECB / OATH (13) · $21,875 owed
IssuedViolationHearingBalance
Dec 24, 2018Construction CLASS - 2
FAILURE TO SAFEGUARD ALL PUBLIC AND PROPERTIES AT THE TIME OF MY INSPECTION 6 STORY NB,CONST. WORK IN PROGRESS OBSERVED MANLIFT IN OPERATION AT(EXPOS 4) MANLIFT PLACED IN ROADWAY.UPCOMING TRAFFIC PASSING BY THE
#35377821P
Jul 29, 2019
IN VIOLATION
$5,000
Dec 24, 2018Construction CLASS - 1
FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING AT THE TIME OF MY INSPECTION6 STORY NB CONST WORK IN PROGRESS.OBSERVED INADEQUATE HOUSEKEEPING THROUGHOUT THE SITE CONST.MATERIALS AND DEBRIS CREATED TRIPPED HAZARD.PRO
#35377820N
Jul 15, 2019
IN VIOLATION
$2,500
Dec 24, 2018Construction CLASS - 1
BC3301.2.FAILURE TO MAINTAIN.AT TIME OF MY INSPECTION 6 STORY NB CONSTWORK IN PROGRESS.OBSERVED PIPE SCAFFOLD AT EXPOS 2 IN PLACED MISSING GUARDRAILS TOE BOARD BASE PLATES AT VARIOUS LOCATIONS WHILE WORKERS PER
#35377822R
Jul 29, 2019
IN VIOLATION
$2,500
Dec 24, 2018Construction CLASS - 1
BC3307.6.5.10.1.SWS DAILY INSPECTION REPORT.AT THE TIME OF MY INSPECTION 6 STORY NB CONST WORK IN PROGRESS.OBSERVED SWS PLACED ON EXP3 1&4.UPON REQUEST INSPECTION LOGS FOR SWS NONE WAS PROVIDED NO SWS DAILY INS
#35377824K
Jul 29, 2019
IN VIOLATION
$625
Dec 24, 2018Construction CLASS - 1
BC3303.9.FAILURE TO MAINTAIN REQUIRED MEANS OF EGRESS DURING CONSTRUCTION.AT TIME OF INSPECTION 6 STORY NB CONSTRCUTION WORK IN PROGRESS.OBSERVED AT EXP2 SANITATION FACILITY AND CONST IN PROGRESS BUT NO REQUIRE
#35377823Z
Jul 29, 2019
IN VIOLATION
$625
Dec 4, 2018Construction CLASS - 1
MISSING GUARDRAILS. AT TIME OF INSPECTION OF A NEW 6 STORY BUILDING UNDER CONSTRUCTION AT ROOF LEVEL I OBSERVED THAT GUARDRAILS WERE MISSING AT ELEVATOR SHAFT.THIS SITUATION CREATES A SERIOUS HAZZARD
#35367242L
Mar 11, 2019
IN VIOLATION
$2,500
Nov 24, 2018Construction CLASS - 1
BC3314.8.1/MESH INSTALLATION NOT MAINTAINED.AT TIME OF INSPECTION OF ANEW 6 STORY BUILDING UNDER CONSTRUCTION AT BULK HEAD LEVEL.I OBSERVED THAT THE MESH ON SCAFFOLD AT EXPO WAS NOT MAINTAINED LARGE OPENING WER
#35367520M
Mar 4, 2019
IN VIOLATION
$625
Oct 25, 2018Construction CLASS - 1
HOUSEKEEPING:AT TIME OF INSPECTION OF A NEW 6 STORY STEEL FRAMED BUILDING UNDER CONSTRUCTION AT 6 STY STAGE ACTIVE JOB SITE-I OBSERVED LARGE (AMOUNT)OF CONSTRUCTION MATERIALS AND AT FIRST FLOOR SCATTERED ALL OV
#35367034R
Apr 22, 2019
IN VIOLATION
$625
Oct 25, 2018Construction CLASS - 1
GUARDRAILS MISSING INADEQUATE. AT TIME OF MY INSPECTION OF A NEW 6 STORY STEEL FRAMED BUILDING UNDER CONSTRUCTION AT 6 STORY STAGE ACTIVE JOB SITE I OBSERVED INADEQUATE GUARDRAILS AT LEADING EDGE OF BALCONY AT
#35367033P
Apr 22, 2019
IN VIOLATION
$2,500
Oct 25, 2018Construction CLASS - 1
3309.10 ROOF PROTECTION. AT TIME OF INSPECTION OF A NEW 6 STORY STEEL FRAMED BUILDING UNDER CONSTRUCTION AT 6 STORY STAGE ACTIVE JOB SITE. IOBSERVED THAT NO ROOF PROTECTION EXISTED AT EXPO#2 REAR OF ADJACENT BU
#35367032N
Apr 15, 2019
IN VIOLATION
$625
Oct 25, 2018Construction CLASS - 2
CONCRETE WASHOUT COLLECTION AND CONTAINMENT AT TIME OF INSPECTION OF A NEW 6 SSTY BLDG UNDER CONSTRUCTION AT 6 STY STAGE ACTIVE JOB SITE (STEEL) FRAME S TRUCTURE.I OBSERVED CONCRETE WASHOUT BEING PERFORMING IN
#35367035Z
Apr 22, 2019
IN VIOLATION
$625
Oct 15, 2018Construction CLASS - 1
FAILURE TO CONFORM WITH NYC FIRE CODE NO FIREGUARD FIRE WATCH.NOTE:AT THE TIME OF INSPECTION A 6 STORY BUILDING AT 5TH FL LEVEL STAIRCASE INSTALLATION WITH WELDING OPERATIONS OBSERVED WITHOUT REQUIRED NO FIRE G
#35351247Y
Feb 24, 2020
IN VIOLATION
$2,500
Aug 21, 2018Construction CLASS - 1
3301.13.1-SITE SAFETY PLAN.NOTE:AT THE TIME OF MY INSPECTION OF A 6 STORY BUILDING AT 2ND FLOOR LEVEL WITH STEEL ERECTED TO 3RD FLOOR LEVEL.UPON REQUEST FOR SITE SAFETY PLANS TO VERIFY COMPLIANCE WITH CODE AND
#35350796M
Jan 28, 2019
IN VIOLATION
$625
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 31, 2026, 10:43 PM ET. BBL 3052177501.