4 floors · 79,330 sq ft · built 1938 · class W1 · owner of record: Nyc Department Of Education
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 79,330 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 187 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 187 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 15 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 431 days | Next cycle year 2027 |
| Energy audit and retro-commissioning (2031) Likely applies Local Law 87 · Calendar year 2031 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 6821). Agency page | Dec 31, 2031 in 1892 days | Next due 2031 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-01-14 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 15, 2026 | Unknown CLASS - 2 ATOI, FAILURE TO PROVIDE AND MAINTAIN REQUIRED SAFETY DEBRIS NETTING AT SCAFFOLD, NOT ONLY IN LOADING AREA BUT IN MULTIPLE SECTIONS OF FIXED SAFETY NETTING OBSERVED MISSING, CREATING A FALLING-OBJECT HAZARD. PR #39204231P | Nov 25, 2026 PENDING | $2,500 |
| Mar 12, 2026 | Construction CLASS - 2 REISSUED 35720626P 2 EMERGENCY LIGHTS IN GYM ON 4TH FLOOR WAS OPERABLE3 EMERGENCY LIGHTS IN GYM ON 3RD FLOOR WAS OPERABLE.EMEGENCY LIGHTS#76,#18 WERE NOT WORKING.REM:REPAIR/REPLACE LIGHTING. #35722595K | Apr 13, 2026 POP/IN-VIO | $0 |
| Mar 12, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NO FIRESTOPPING PER BC 712.3;27-345.AT THE TIME OF INSPECTION,ELECTRICAL METER ROOM HAD MULTIPLE THROUGH WALL PENETRATION WITH NO FIRESTOPPING.REM:PROVIDE/M #35722599H | Apr 13, 2026 POP/IN-VIO | $0 |
| Mar 12, 2026 | Construction CLASS - 2 REISSUED 35719747N TEMPORARY CERTIFICATE OF OCCUPANCY 300911770 EXPIRED ON 1/30/2001.NO SUPERSEDED TCO IN EFFECT.REM:OBTAIN VALID COFO OR DISCONTINUE ILLEGAL OCCUPANCY. #35722598X | Apr 13, 2026 POP/IN-VIO | $0 |
| Mar 12, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.AT THE TIME OF INSPECTION THE FOLLOWING ROOM DOORS WERE NOT SELF-CLOSING-416,411,414,408,409,405,403,303,309,307,313,321,319,219,214,205,203,109,117,118,120 #35722594Z | Apr 13, 2026 POP/IN-VIO | $0 |
| Mar 12, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1.8;27-371(J).AT THE TIME OF INSPECTION,THE FOLLOWING ROOM DOORS HAD TURN KNOB HANDLES-421,420,418,417,41 #35722596M | Apr 13, 2026 POP/IN-VIO | $0 |
| Mar 12, 2026 | Construction CLASS - 2 REISSUED:35720627R BROKEN MIRROR IN DANCE ROOM(406),CRACKS AND SPALLING IN ROOMS STAIRCASE A,B,CLASSROOM#312,308,303.GAS METER ROOM HAD EFFORESCENCE FROM MATTER INFILTRATION ALONG EAST 17TH STREET.REM:REPAIR AN #35722597Y | Apr 13, 2026 POP/IN-VIO | $0 |
| Mar 19, 2025 | Construction CLASS - 2 REISSUE #35682862M: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: OBSERVED AT STAIRCASE A AND B INCLUDED CLASSROOM A312, 308A, A303CRACKS, SPALLING ON WALLS, CEILING. REMEDY: REPAIR AND/OR REPLACE. #35692114X | May 1, 2025 POP/IN-VIO | $0 |
| Mar 19, 2025 | Construction CLASS - 2 ALTERED/CHANGED BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY AS PER 28-118.3.1-28.118.3.2.ISSUE SUMPPERS WHERE ALT TYPE JOB 30091770 PERMIT WAS ISSUED AND SIGNED OFF.COFO#30091770 TEMPORARY EXPIRE #35719747N | Aug 20, 2025 POP/IN-VIO | $0 |
| Mar 19, 2025 | Construction CLASS - 2 REISSUE #35682863Y; FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER 1006.1, 27-381. EXISTING EMERGENCY LIGHT ARE NOT OPERATIONAL WHEN TEST #35692113Y | May 1, 2025 POP/IN-VIO | $0 |
| Mar 19, 2025 | Construction CLASS - 2 REISSUE#35682862M FAILURE TO MAINTAIN BUILDING IN COMPLIANT MANNER.STAIR B,STAIR A AND CLASSROOMS#A303,A308,A312 CRACK,LEAKS ON WALLS,CEILINGS.REM:REPAIR/AND OR REPLACE. #35720627R | Aug 20, 2025 POP/IN-VIO | $0 |
| Mar 19, 2025 | Construction CLASS - 2 REISSUE#35682863Y FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.ILLUMINATION EXITS,EXIT DISCHANGES AND PUBLIC CORIDORS PER BC 1006.1;27-381.OBSERVED AT STAIR B AND 3RD GYM,4TH FLOORS GYM NOT OPERATIONAL #35720626P | Aug 20, 2025 POP/IN-VIO | $0 |
| Jun 12, 2024 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER:ILLUMINATION FOREXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-381.NOTED:ON THE FOURTH FLOOR GYMNASIUM TWO LIGHTS,THIRD FLOOR GYMNASIUM TWO LIG #35682863Y | Aug 21, 2024 POP/IN-VIO | $0 |
| Jun 12, 2024 | Construction CLASS - 2 REISSUE#35672066M FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:OBSERVED AT STAIR B,STAIR A,AND CLASS ROOMS A303,A308,A312.THERE ARE CRACKS AT ALL THESE LOCATION LISTED ABOVE.REM:REPAIR AND/OR REP #35682862M | Aug 21, 2024 POP/IN-VIO | $0 |
| Mar 16, 2023 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NEW WING OF SCHOOL STAIRCASE 1&B CRACKS IN SIDE STAIRCASE & ON OLD SIDE FACADE.3RD FL CRACKS ON FL GOING FROM RM 312 ACROSS HALL TO RM 309.2ND FL CRACKS ON #35672066M | Jun 7, 2023 POP/IN-VIO | $0 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Sep 15, 2026 | ECB | Unknown: ATOI, FAILURE TO PROVIDE AND MAINTAIN REQUIRED SAFETY DEBRIS NETTING AT SCAFFOLD, NOT ONLY IN LOADING AREA BUT IN MULTIPLE SECTIONS OF FIXED SAFETY NETTING OBSERVED MISSING, CREATING A FALLING-OBJECT HAZARD. PR | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 26, 2026, 7:33 PM ET. BBL 3068210244.