9 floors · 21 apartments · 39,222 sq ft · built 1923 · class D4 · owner of record: 17 E 84 St Corp
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 45 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 45 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 45 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 61 days | Annual |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page | Feb 21, 2027 in 97 days | No Cycle 10 report on record yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 39,222 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 166 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 166 days | Annual filing |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-06-16 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 13, 2026 | Unknown CLASS - 1 NOTE: AT TIME OF INSPECTION I OBSERVED MULTIPLE SUSPENDED SCAFFOLD IN USE FOR FACADE OPERATIONS, UPON REQUEST FOR THE INSTALLATION INSPECTION LETTER TO VERIFY THE SAFETY AND THAT THE SCAFFOLD WAS BUILT AS PER D #39560581X | Dec 24, 2026 PENDING | $5,000 |
| Oct 13, 2026 | Unknown CLASS - 2 NOTE: AT TIME OF INSPECTION, I OBSERVED AN INADEQUATE STORAGE AREA ON THE ROADWAY, THE SYNTHETIC NETTING WAS NOT SECURELY ATTACHED TO THE SIDEWALK SHED AND NO SOLID BARRIERS WAS PROVIDED AS PER 3307.4.7, CREATI #39560582H | Dec 24, 2026 PENDING | $2,500 |
| Oct 13, 2026 | Unknown CLASS - 2 NOTE: AT TIME OF INSPECTION, I OBSERVED A STORAGE ZONE ON THE ROADWAY CREATING AN OBSTRUCTION, UPON REVIEWING THE DOT PERMIT IT WAS NOTED THAT THE PERMIT WAS EXPIRED CONTRARY TO 3307.2.1, THIS SITUATION CREATES #39560583J | Dec 24, 2026 PENDING | $2,500 |
| Issued | Violation | Status |
|---|---|---|
| Sep 6, 2019 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST #02974 | DOB VIOLATION - ACTIVE |
| Sep 6, 2019 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST #02973 | DOB VIOLATION - ACTIVE |
| May 30, 2014 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2012 CAT 1 INSP/TST #03703 | DOB VIOLATION - ACTIVE |
| May 15, 2014 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT #00365 | DOB VIOLATION - ACTIVE |
| Apr 21, 2004 | LOCAL LAW 10/81 - ELEVATOR #01231 | DOB VIOLATION - ACTIVE |
| Mar 19, 2003 | LOCAL LAW 62/91 - BOILERS #04379 | DOB VIOLATION - ACTIVE |
| Mar 26, 2002 | LOCAL LAW 62/91 - BOILERS #04581 | DOB VIOLATION - ACTIVE |
| Sep 30, 1999 | ELEVATOR 1P12683 #9013/112869 | DOB VIOLATION - ACTIVE |
| Apr 25, 1991 | LOCAL LAW 10/81 - ELEVATOR 2 #01167 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 11, 2024 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Report | Active |
| Sep 11, 2024 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Report | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Report | Active |
| Sep 6, 2019 | Elevators ACC1 | Active |
| Sep 6, 2019 | Elevators ACC1 | Active |
| May 30, 2014 | Elevators ACC1 | Active |
| May 15, 2014 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT | Active |
| Apr 21, 2004 | Elevators LL1081 | Active |
| Apr 21, 2004 | Elevators LL1081 | Active |
| Mar 19, 2003 | Boiler LL6291 | Active |
| Mar 26, 2002 | Boiler LL6291 | Active |
| Apr 25, 1991 | Elevators LL1081 | Active |
| Apr 25, 1991 | Elevators LL1081 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Aug 6, 2009 | A | Apt 8B · SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT EAST WALL NORTHEAST ROOM SOUTH WALL SOUTHWEST ROOM 8 STY NORTH APT 8B LOCATED AT APT 8B | Nov 9, 2009 |
| Aug 6, 2009 | B | Apt 8B · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WATER DAMAGED WOOD FLOOR NORTHEAST & SOUTHWEST ROOMS 8 STY NORTH APT 8B LOCATED AT APT 8B | Sep 10, 2009 |
| Aug 6, 2009 | B | Apt 8B · SECTION 27-2005 ADM CODE PROPERLY SECURE THE LOOSE ELECTRICAL CEILING LIGHT FIXTURE WATERCLOSET ROOM CENTER EAST 8 STY NORTH APT 8B LOCATED AT APT 8B | Sep 10, 2009 |
| Aug 6, 2009 | B | Apt 8B · SECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN ROACHES 8 STY NORTH APT 8B THRU OUT LOCATED AT APT 8B | Sep 10, 2009 |
| Aug 6, 2009 | A | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WEST WALL 7 TO 8 STY & CEILING & WALLS 10 STY PUBLC HALL | Nov 9, 2009 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 13, 2026 | ECB | Unknown: NOTE: AT TIME OF INSPECTION I OBSERVED MULTIPLE SUSPENDED SCAFFOLD IN USE FOR FACADE OPERATIONS, UPON REQUEST FOR THE INSTALLATION INSPECTION LETTER TO VERIFY THE SAFETY AND THAT THE SCAFFOLD WAS BUILT AS PER D | Open |
| Oct 13, 2026 | ECB | Unknown: NOTE: AT TIME OF INSPECTION, I OBSERVED AN INADEQUATE STORAGE AREA ON THE ROADWAY, THE SYNTHETIC NETTING WAS NOT SECURELY ATTACHED TO THE SIDEWALK SHED AND NO SOLID BARRIERS WAS PROVIDED AS PER 3307.4.7, CREATI | Open |
| Oct 13, 2026 | ECB | Unknown: NOTE: AT TIME OF INSPECTION, I OBSERVED A STORAGE ZONE ON THE ROADWAY CREATING AN OBSTRUCTION, UPON REVIEWING THE DOT PERMIT IT WAS NOTED THAT THE PERMIT WAS EXPIRED CONTRARY TO 3307.2.1, THIS SITUATION CREATES | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 16, 2026, 2:45 PM ET. BBL 1014960013.