13 floors · 46 apartments · 38,518 sq ft · built 2023 · class D1 · owner of record: Spaxel Cbre 1695 Monroe Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 64 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 64 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 64 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 80 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 38,518 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 185 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 185 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Facade inspection report (Cycle 10C) Applies Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. Agency page | Feb 21, 2029 in 847 days | Filing window not open yet |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 9, 2025 | Construction CLASS - 2 13 STORY NB ACTIVE SITE.SIDEWALK SHED IN PLACE AT EXP#1,2 12' IN HEIGHT PERMIT#X01271855. INSTALLED CONTRARY TO PLANS/NOT MAINTAINED IN SAFE MANOR.SHED OVERLOADED WITH HEAVY MATERIALS STORED RED BRICK & OTHER M #39544726H | Oct 9, 2026 IN VIOLATION | $625 |
| Sep 9, 2025 | Construction CLASS - 2 13 STORY NB ACTIVE SITE.SUPPORTED SCAFFOLD IN PLACE APPROX. 120' HEIGHT CONTRARY TO PLANS ONSITE PERMIT#X01086087.OBSERVED MULTIPLE UNSAFE CONDITIONS LOOSE EXTERIOR NETTING AT EXP#4 TIEBACKS NOT PROPERLY ATTACH #39544718H | Oct 9, 2026 IN VIOLATION | $625 |
| Sep 9, 2025 | Unknown CLASS - 2 13 STORY NEW BUILDING ACTIVE SITE OBSERVED FIRE EXTINGUISHER'S ONSITE AT MULTIPLE LOCATIONS NOT PROPERLY MAINTAINED LEFT ON GROUND NOT HUNG OR RAISED 4 INCHES OFF THE GROUND LEFT HOLDING DOORWAYS MISSING SIGNAG #39544729N | Nov 21, 2025 IN VIOLATION | $625 |
| Sep 9, 2025 | Construction CLASS - 1 A 13 STORY NEW BUILDING ACTIVE SITE. OBSERVED NO/MISSING OR INADEQUATE HANDRAILS & TEMPORARY LIGHTING ON A/B EGRESS/INGRESS. DARK STAIRCASES FROM 10 TO 13TH FLOOR CREATING A SLIP, TRIP & FALL HAZARD UNSAFE FOR #39544728L | Nov 21, 2025 IN VIOLATION | $2,500 |
| Sep 9, 2025 | Construction CLASS - 1 13 STORY NEW BUILDING ACTIVE SITE.OBSERVED MISSING/INADEQUATE GUARDRAILS ON EXTERIOR/INTERIOR OPENINGS ELEVATOR SHAFTS.CREATING FALL HAZARD TO WORKER'S ONSITE.AT EXTERIOR EXP#3 12,13 FL MISSING TOE BOARDS & NET #39544727J | Nov 21, 2025 IN VIOLATION | $5,000 |
| Jun 25, 2025 | Construction CLASS - 2 OBSERVED HORIZONTAL BRACE DISLODGED FROM SWS, AS WELL AS CROSS BRACING, SCAFFOLD FRAMES, OSHA PLANKS AND SCAFFOLD STAIRCASE STORED ON TOP OFSWS. WHEN REVIEWING ONSITE SWS PLANS, DRAWINGS STATE NO MATERIALS ARE #39541701H | Dec 19, 2025 IN VIOLATION | $625 |
| Jun 25, 2025 | Unknown CLASS - 1 3305.1 UNSAFE CONDITIONS.OBSERVED 13 STORY NB WITH INADEQUATE HOUSEKEEPING THROUGHOUT ENTIRE JOBSITE. METAL FRAMING, BROKEN & CUT SHEET ROCK, GARBAGE BAGS, ECT. SCATTERED AROUND EACH FLOOR BLOCKING EGRESS & CRE #39541703L | Oct 30, 2026 | $5,000 |
| Jun 25, 2025 | Unknown CLASS - 2 BC 3307.6.5.10 & BC 3314.4.3.5 INADEQUATE SWS AND SCAFFOLD DAILY INSPECTION. OBSERVED PIPE SCAFFOLD ON TOP OF SWS @ EXPO1. UPON REVIEW OF ONSITE DOCUMENTS, THE INSPECTION REPORTS PROVIDED DID NOT SHOW CURRENT V #39541704N | Oct 30, 2026 | $2,500 |
| Jun 25, 2025 | Construction CLASS - 1 OBSERVED 13 STORY NB ACTIVE JOBSITE WITH THE SSC ON PW2 (JACOB C NOLAN # 002967) LICENSE EXPIRED 06/21/2025. GC FAILED TO DESIGNATE NEW SSC ON PW2. STOP ALL WORK ENTIRE JOBSITE PROVIDE/DESIGNATE SITE SAFETY MAN #39541705P | Oct 30, 2026 | $10,000 |
| Jun 25, 2025 | Unknown CLASS - 1 BC 3314.1 SCOPE. OBSERVED PIPE SCAFFOLD AT EXPO1. UPON REVIEW OF PIPE SCAFFOLD PLANS ONSITE NO FULL DECKED OUT FLOORS ARE ALLOWED, SIDE BRACKETS THROUGHOUT SCAFFOLD CONNECTED WITH TIRE WIRE AND NOT METAL PINS, #39541702J | Oct 30, 2026 | $5,000 |
| Dec 10, 2024 | Construction CLASS - 1 AT TIME OF MY INSPECTION I OBSERVED A PROPOSED 13 STORY BUILDING AT 7TH FLOOR LEVEL. I NOTICED THAT AT STAIRSCASE FROM THE 4TH FLOOR UP TO THE 7TH FLOOR AT VARIOUS LOCATION MISSING HAND RAILS. THIS CREATES A UN #39534997K | Oct 17, 2025 IN VIOLATION | $2,500 |
| Dec 10, 2024 | Unknown CLASS - 1 3301.1.2 FIRE CODE. AT TIME OF MY INSPECTION ON THE 5TH FLOOR I NOTICED 2 MILLER GAS GENERATOR WITH IMPROPERLY VENTILATION TO EXTERIOR OF BUILDING. THIS CREATES A HAZARDOUS CONDITION WITH EXHAUST FUMES BEING VE #39534995R | Oct 17, 2025 IN VIOLATION | $5,000 |
| Dec 10, 2024 | Unknown CLASS - 1 3301.1.2 FIRE CODE. AT A PROPOSED 13 STORY AT 7TH FLOOR. I NOTICED AT EXPOSURE 3 REAR YARD A METAL STORAGE CONTAINER WITH 9 GASOLINE CONTAINER AND 2 PROPANE TANKS AND 4 GENERATORS. UPON REQUESTING FOR FDNY PERM #39534994P | Oct 17, 2025 IN VIOLATION | $5,000 |
| Dec 10, 2024 | Construction CLASS - 1 AT TIME OF MY INSPECTION OF A PROPOSED 13 STORY BUILDING AT 7TH FLOOR. I NOTICED AT REAR YARD EXPOSURE#3 A GREEN GENERATOR; UPON REVIEWING APPROVED SITE SAFETY PLAN I OBSERVED NO INDICATION OF GENERATOR TO BE P #39534996Z | Oct 17, 2025 IN VIOLATION | $625 |
| Jul 19, 2024 | Unknown CLASS - 1 BC 3303.4 WATER CONDITIONS: AT TIME OF INSPECTION AT ACTIVE JOBSITE CURRENTLY AT 3RD STORY I OBSERVED STANDING WATER MORE THAN 3INCHES DEEP AT BASEMENT LEVEL CREATING A HEALTH HAZARD AS A BREEDING GROUND FOR MO #39530679R | Mar 21, 2025 IN VIOLATION | $0 |
| Sep 24, 2021 | Construction CLASS - 1 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#39027313Y ISSUED ON 8/20/2020 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01.NO PERMIT OR APPLICATIO #35563046M | Dec 17, 2021 IN VIOLATION | $6,250 |
| Oct 16, 2020 | Construction CLASS - 1 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#39027313Y ISSUED ON 08/20/20 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCY 102-01.WORK WITHOUT PERMIT AT BA #35522617X | Apr 23, 2021 IN VIOLATION | $2,500 |
None open.
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Aug 13, 2009 | C | Apt 2NDFL · SECTION 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2NDFL, 2nd STORY | Aug 19, 2009 |
| Aug 13, 2009 | B | Apt 2FL · SECTION 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2FL, 2nd STORY | Sep 17, 2009 |
| Aug 13, 2009 | C | Apt 2FL · SECTION 27-2018 ADMIN. CODE: ABATE THE NUISNACE CONSISTING OF RODENTS RATS , IN THE ENTIRE APARTMENT LOCATED AT APT 2FL, 2nd STORY | Aug 19, 2009 |
| Aug 13, 2009 | A | Apt 2FL · SECTION 27-2005 ADMIN. CODE: REFIT THE DRAWER'S AND DOOR'S AT SINK CABINET , IN THE KITCHEN LOCATED AT APT 2FL, 2nd STORY | Nov 16, 2009 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 28, 2026, 6:40 AM ET. BBL 2027920044.