4 floors · 18 apartments · 4,950 sq ft · built 1905 · class C1 · owner of record: 169 Washington Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 68 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 68 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2019-12-31 (Accepted). Agency page | Dec 31, 2026 in 68 days | 1 of 1 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 84 days | Annual |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1164 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 1, 2025 | Boilers CLASS - 2 FAILURE TO FILE REQUIRED ANNUAL BOILER INSPECTION REPORTS FOR LOW-PRESSURE BOILER 30000944230Y0001 IN ACCORDANCE WITH THE RULES OF THE DEPARTMENT.1RCNY 103-01(D)(1)REQUIRES THAT AN ANNUAL INSPECTION REPORT FOR #37035771Z | Oct 1, 2025 DEFAULT | $3,125 |
| Feb 14, 2022 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#39038866H ISSUED ON 4/6/2021 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01.FOR WORK DOES NOT CONFOR #35567926Z | Jul 6, 2022 DEFAULT | $3,125 |
| Feb 14, 2022 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#39038865X ISSUED ON 4/6/2021 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01.FOR OCCUPANCY CONTRARY T #35567927K | Jul 6, 2022 DEFAULT | $3,125 |
| Sep 24, 2021 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #39038866H ISSUED 4/6/21 AND FILE CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01.WORK DOES NOT CONFORM TO APPROVED PLA #35562828M | Feb 2, 2022 DEFAULT | $3,125 |
| Sep 24, 2021 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #39038865X ISSUED 4/6/21 AND FILE CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01.OCCUPANCY CONTRARY.REMEDY:COMPLY WITH #35562827K | Feb 2, 2022 DEFAULT | $3,125 |
| Aug 9, 2021 | Construction CLASS - 2 OCCUPANCY CONTRARY TO THAT ALLOWED BY C/O OR DOB RECORDS FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN SUMMONS/V39038865X ISSUED 4/6/21 &TO FILE C/C PURSUANT TO28-201.1&1RCNY102-01.PREV ECB35530889J COM #35535392R | Dec 22, 2021 DEFAULT | $5,000 |
| Aug 9, 2021 | Construction CLASS - 2 WORK DOESNT CONFORM TO APPROVED PLANS/AMENDMENTS FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN SUMMONS/V39038866H ISSUED4/6/21&TO FILE C/C PURSUANT TO28-201.1&1RCNY102.01.PREV ECB35530888H COMPLY W/COMM #35535393Z | Dec 22, 2021 DEFAULT | $5,000 |
| May 19, 2021 | Construction CLASS - 2 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#39038866H ISSUED ON 04/06/21 & TO FILE A CERT OF CORRECTION PURSUANT TO 28-201.1 & 1RCNY 102-01. WORK DOES NOT CONFORM TO APPROVED PLANS FOR ALT-3 #35530888H | Nov 19, 2021 DEFAULT | $3,125 |
| May 19, 2021 | Construction CLASS - 2 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#39038865X ISSUED ON 04/06/21 & TO FILE A CERT OF CORRECTION PURSUANT TO 28-201.1 & 1RCNY 102-01. OCCUPANCY CONTRARY TO C OF O OR BLDG RECORDS. AT TI #35530889J | Nov 19, 2021 DEFAULT | $3,125 |
| Apr 6, 2021 | Construction CLASS - 1 AT TIME OF INSPECTION, PREMISES OCCUPIED AS MULTIPLE DWELLING WITH 3 CLASS A APARTMENTS AND ONE SRO - SAID OCCUPANCY IS CONTRARY TO COFO #112597 ISSUED 5-16-1945 AND HPD REGISTRATION #338328 WHICH STATE PREMISE #39038865X | Oct 15, 2021 DEFAULT | $12,500 |
| Apr 6, 2021 | Construction CLASS - 1 AT TIME OF INSPECTION, WORK AT BASEMENT, 1ST, 2ND AND 3RD FLOORS GROSSLY NONCONFORMING TO APPROVED PLANS FOR ALT 3 JOB #322018534 - CLASS A APARTMENTS CREATED AT 3RD AND 2ND FLOORS, CLASS A DUPLEX APARTMENT CRE #39038866H | Oct 15, 2021 DEFAULT | $12,500 |
| May 2, 2020 | Unknown CLASS - 2 UNLAWFUL ACTS AT TIME OF INSPECTION OBSERVED ONGOING CONSTRUCTION ACTIVITIES THAT CONSISTS OF INTERIORS DEMOLITION ACTIVITIES OF WALLS AND CEILING THROUGHOUT BUILDING WITH 2 WORKERS ONGOING DEMOLIION ACTIVITIES #35467129H | Sep 2, 2020 DEFAULT | $10,000 |
| Feb 7, 2018 | Unknown CLASS - 2 UNAPPROVED UNSAFE UNSUITABLE ELECRICAL EQUPMENT DEVICES APPARATUS APPLIANCES MATERIALS OR WIRING IN USE. ELECTRICAL OUTLET BOXES NOT SUPPORTED IN BASEMENT ALSO SPLICE BOX COVERS MISSING, FLEXIBLE CORD USED AS #35312790Y | Sep 26, 2018 IN VIOLATION | $0 |
| Feb 7, 2018 | Construction CLASS - 1 WORK W/O A PERMIT. I OBSERVED IN CELLAR NEWLY INSTALLED GAS PIPING FITTINGS & VALVES CONNECTED TO A BOILER HOT WATER HEATER & COOKING GAS THROUGHOUT BLDG. NO PERMITS ON FILE,I OBSERVED NEWLY INSTALLED GAS BOILE #35268696M | Apr 2, 2018 DEFAULT | $0 |
| Feb 7, 2018 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. I OBSERVED IN CELLAR FOR NEWLY INSTALLED GAS PIPING AN APPLIANCE VALVE INSTALLED ON MAIN RUB IF GAS LINE IN THE MIDDLE OF THE CELLAR WHICH IS PROHOBITED & NOT #35268699H | Apr 2, 2018 DEFAULT | $0 |
| Feb 7, 2018 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. I OBSERVED THROUGHOUT BLDG IN STAIRWELLS SEVERAL SPRINKLER HEADS W/PAINT ON THEM WHICH IS PROHIBITED & NOT CODE COMPLIANT & CAN CAUSE A DANGEROUS IF THERE WAS #35268802R | Sep 26, 2018 IN VIOLATION | $0 |
| Feb 7, 2018 | Plumbing CLASS - 1 FAILURE TO HAVE NEW OR ALTERED PLUMBING SYSTEM TESTED. I OBSERVED IN CELLAR NEWLY INSTALLED GAS PIPING FITTINGS & VALVES & BOILER FOR GAS PIPE COOKING GAS & HEATING UNITS & NO PROPER TESTING WAS PERFORMED ON #35268697Y | Apr 2, 2018 DEFAULT | $0 |
| Feb 7, 2018 | Plumbing CLASS - 1 GAS BEING SUPPLIED TO BLDG W/O INSPECTIONS & CERTIFICATIONS GIVEN BY DOB. I OBSERVED IN CELLAR NEWLY INSTALLED GAS PIPING & FITTING & VALVESFOR HEATING & COOKING THROUGHOUT BLDG & GAS VALVE FOR GAS METER WAS IN #35268698X | Apr 2, 2018 DEFAULT | $0 |
| Feb 7, 2018 | Unknown CLASS - 2 FAIL TO PROVIDE EFFECTIVE ELECTRICAL CONTINUITY FOR METAL RACEWAYS EN CLOSURES CABLE ARMOR. SERVICE GROUND RACEWAY NOT CONTINUOUS IN BASE MENT. RMDY: PROVIDE EFFECTIVE ELECTRICAL CONTINUITY (OBTAIN PERMIT) #35312792H | Apr 2, 2018 DEFAULT | $0 |
| Feb 27, 2017 | Boilers CLASS - 2 AS PER CLASS 2 (B265) 38-303.7 FAILURE TO FILE A COMPLETE BOILER INSPECTION REPORT AS PER DOB RECORDS. SUBMIT A CURRENT B09 REPORT. #32087516Y | Apr 17, 2017 DEFAULT | $0 |
| Jul 13, 2012 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERT OF CORRECTION WITH THE DOB. NOTED:NO CERT OF CORRECTION HAS BEEN FILED FOR NOV 32065645N ISSUED 3/2/09. REM:FILE CERT OF CORRECTION. #34985768H | Aug 27, 2012 IN VIOLATION | $0 |
| Mar 27, 2009 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. DEFECTS NOTED: BROKEN AND DEFECTIVE RAILING AT STAIR PRIMARY MEANS OF EGRESS W/ MISSING AND LOOSE BALUSTERS AND BROKEN DEFECTIVE LOOSE SPLIT WOODEN STAIR TREAD #34767401X | May 18, 2009 WRITTEN OFF | $0 |
| Mar 27, 2009 | Construction CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTED: AT PUBLIC HALL1ST, 2ND AND 3RD FOUND W/ THE STORAGE OF RUBBISH AND OTHER OBSTRUCTINGEGRESS AT PRIMARY MEANS OF EGRESS FOR SAID PREMISES. REMEDY: REMOVE #34767400Y | May 18, 2009 WRITTEN OFF | $0 |
| Mar 27, 2009 | Construction CLASS - 2 FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING AS FOR SECTION REEP. NOTED: AT FOURTH FLR AND 3RD FLR APTS FOUND W/ THE STORAGE OF CONSTRUCTION MATERIAL DEBRIS IN NUMEROUS PLASTIC BAGS AND ALSO COMBUSTIBLE MATERIAL #34767402H | May 18, 2009 WRITTEN OFF | $0 |
| Mar 2, 2009 | Construction CLASS - 1 105.1,51,36,B101,50,50A,B,C. 50-NO FUSABLE LINK FIRE DAMPER.50A-HOLES IN WALL.50B-BOILER NOT LEVEL.50C-BOILER NOT BIG ENOUGH FOR HOUSE 105,000. #32065645N | Apr 27, 2009 WRITTEN OFF | $0 |
| Feb 18, 2009 | Construction CLASS - 1 WORK W/O A PERMIT WORK NOTED FULL HEIGHT SHEET ROCK PARTITION WALLS ERECTED AT BSMT TO ILLEGALLY CONVERT IT INTO A CLASS A DWELLING UNIT W/ BDRM LIVING RM KTCN W/ GAS STOVE & SINK 3PC BTRM W/ SINK SHOWER/TUB & #34757487R | Apr 13, 2009 WRITTEN OFF | $0 |
| Feb 18, 2009 | Construction CLASS - 2 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERT OF OCCUPANCY NOTE CERT OF OCCUPANCY W/ #112507 ISSUED MAY 16 1945 INDICATES BSMT TO BE USED AS 3 FURNISHED RMS NOW BSMT HAS BEEN ILLEGALLY CONVERTED INTO CLASS A D #34757488Z | Apr 13, 2009 WRITTEN OFF | $0 |
| Aug 14, 2006 | Construction Non-Hazardous WORK WITHOUT A PERMIT - HAZARDOUS. NOTED:APPL #301888125 APPROVED TO REDUCE OCCUPANCY. NO PERMIT ISSUED @ TIME OF INSPECTION FOR CONSTRUCTION WORK & NOW OBSERVED FULL PARTITION WALLS ILLEGALLY REMOVED IN 1ST, #34535610J | Oct 2, 2006 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #10450 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #09390 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION #33912 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION #13559 | DOB VIOLATION - ACTIVE |
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION #13336 | DOB VIOLATION - ACTIVE |
| Apr 25, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION #19529 | DOB VIOLATION - ACTIVE |
| Jul 7, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00269 | DOB VIOLATION - ACTIVE |
| Jul 7, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00270 | DOB VIOLATION - ACTIVE |
| Nov 8, 2019 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT #12151 | DOB VIOLATION - ACTIVE |
| May 2, 2018 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00276 | DOB VIOLATION - ACTIVE |
| May 2, 2018 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00278 | DOB VIOLATION - ACTIVE |
| May 2, 2018 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00277 | DOB VIOLATION - ACTIVE |
| May 2, 2018 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00279 | DOB VIOLATION - ACTIVE |
| Apr 6, 2018 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT #14778 | DOB VIOLATION - ACTIVE |
| Oct 1, 2015 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT #11341 | DOB VIOLATION - ACTIVE |
| Mar 3, 2015 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT #13626 | DOB VIOLATION - ACTIVE |
| May 15, 2014 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT #10446 | DOB VIOLATION - ACTIVE |
| Dec 13, 2011 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT #10791 | DOB VIOLATION - ACTIVE |
| Dec 31, 2009 | LOW PRESSURE BOILER #12732 | DOB VIOLATION - ACTIVE |
| Mar 27, 2009 | CONSTRUCTION #0201AA | DOB VIOLATION - ACTIVE |
| Jan 3, 2008 | LOCAL LAW 62/91 - BOILERS #20598 | DOB VIOLATION - ACTIVE |
| Jan 6, 2006 | LOCAL LAW 62/91 - BOILERS #20217 | DOB VIOLATION - ACTIVE |
| Feb 13, 2004 | LOCAL LAW 62/91 - BOILERS #22735 | DOB VIOLATION - ACTIVE |
| Mar 19, 2003 | LOCAL LAW 62/91 - BOILERS #17008 | DOB VIOLATION - ACTIVE |
| May 4, 1998 | LOCAL LAW 62/91 - BOILERS #28208 | DOB VIOLATION - ACTIVE |
| Sep 16, 1997 | LOCAL LAW 62/91 - BOILERS #224483 | DOB VIOLATION - ACTIVE |
| Feb 10, 1997 | LOCAL LAW 62/91 - BOILERS #22572 | DOB VIOLATION - ACTIVE |
| Aug 29, 1995 | LOCAL LAW 62/91 - BOILERS #39070 | DOB VIOLATION - ACTIVE |
| Jun 1, 1994 | LOCAL LAW 62/91 - BOILERS #30819 | DOB VIOLATION - ACTIVE |
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #40085 | DOB VIOLATION - ACTIVE |
| Jun 1, 1993 | LOCAL LAW 62/91 - BOILERS #30818 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Sep 18, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle B (premises is in Community District 2) | Active |
| Sep 23, 2024 | Boiler LBLVIO Violation Issued-Failure To File 2023 External Low Pressure Inspection Report | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Apr 25, 2023 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2022 INSPECTION REPORT | Active |
| Jul 7, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Jul 7, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Nov 8, 2019 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT | Active |
| May 2, 2018 | AEUHAZ FTC-AEU-HAZ | Active |
| May 2, 2018 | AEUHAZ FTC-AEU-HAZ | Active |
| May 2, 2018 | AEUHAZ FTC-AEU-HAZ | Active |
| May 2, 2018 | AEUHAZ FTC-AEU-HAZ | Active |
| Apr 6, 2018 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT | Active |
| Oct 1, 2015 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT | Active |
| Mar 3, 2015 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT | Active |
| May 15, 2014 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT | Active |
| Dec 13, 2011 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT | Active |
| Dec 31, 2009 | Boiler LBLVIO | Active |
| Jan 3, 2008 | Boiler LL6291 | Active |
| Jan 6, 2006 | Boiler LL6291 | Active |
| Feb 13, 2004 | Boiler LL6291 | Active |
| Mar 19, 2003 | Boiler LL6291 | Active |
| May 4, 1998 | Boiler LL6291 | Active |
| Sep 16, 1997 | Boiler LL6291 | Active |
| Feb 10, 1997 | Boiler LL6291 | Active |
| Aug 29, 1995 | Boiler LL6291 | Active |
| Jun 1, 1994 | Boiler LL6291 | Active |
| Jun 1, 1993 | Boiler LL6291 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Feb 8, 2024 | C | Apt 4 · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SCALDING HOT WATER CONSISTING OF 151 DEGREESE FARENHEIT AT ALL FIXTURES THERMOMETER # A2030 LOCATED AT APT 4, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Feb 14, 2024 |
| Jan 26, 2024 | B | Apt 4 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Mar 1, 2024 |
| Jan 26, 2024 | B | Apt 4 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Mar 1, 2024 |
| Apr 28, 2023 | C | Apt 4 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | May 24, 2023 |
| Apr 28, 2023 | C | Apt 4 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | May 24, 2023 |
| Dec 7, 2020 | C | Apt 4 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Jan 2, 2021 |
| Dec 7, 2020 | C | Apt 4 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Jan 2, 2021 |
| Dec 7, 2020 | B | Apt 4 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF BEDBUGS LOCATED AT B-ROOM 4, 1st STORY, 1st B-ROOM FROM NORTH AT EAST | Jan 11, 2021 |
| Dec 7, 2020 | C | Apt 4 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES LOCATED AT B-ROOM 4, 1st STORY, 1st B-ROOM FROM NORTH AT EAST | Jan 2, 2021 |
| Dec 7, 2020 | C | Apt 4 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE LOCATED AT B-ROOM 4, 1st STORY, 1st B-ROOM FROM NORTH AT EAST | Jan 2, 2021 |
| Feb 2, 1999 | C | § 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT CEILING SOUTH OOM 4 STY EAST APT B ROOM 10 FORTOZO 797 5327 ER1 23114 | Feb 22, 1999 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 24, 2026, 10:02 PM ET. BBL 3020720009.