16 floors · 125 apartments · 217,360 sq ft · built 1961 · class D1 · owner of record: Nyc Housing Authority
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 58 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 58 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 74 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 217,360 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 179 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 179 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Facade inspection report (Cycle 10B) Applies Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. Agency page | Feb 21, 2028 in 475 days | No Cycle 10 report on record yet |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 789 days | Next cycle year 2028 |
| Energy audit and retro-commissioning (2028) Likely applies Local Law 87 · Calendar year 2028 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2548). Agency page | Dec 31, 2028 in 789 days | Next due 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 31, 2025 | Construction CLASS - 2 AT THE TIME OF INSPECTION UPON REQUEST TO SEE & VERIFY DOCUMENTS NON WERE PROVIDED OR PRESENTLY ONSITE AS PER BC CODE 3301.7 (NO INSTALLATION INSPECTION REPORT FOR OUTRIGGERS INSTALLED & IN USED) #39543091Z | Oct 17, 2025 ADMIT/IN-VIO | $0 |
| Jul 31, 2025 | Construction CLASS - 2 AT TIME OF INSPECTION, I OBSERVED 5 OUTRIGGERS BEAM SUSPENDED SCAFFOLDS INSTALLED CONTRARY TO THE APPROVED DESIGNED DRAWING, NO DETAILS FOR TIEBACK WRAPPED AROUND BULKHEAD #39543092K | Oct 17, 2025 ADMIT/IN-VIO | $0 |
| Jul 8, 2024 | Construction CLASS - 2 ALTERATION OF A 16 STORY NYCHA BUILDING ACTIVE SITE. OBSERVED AT EXP#1,2 CONTRACTOR TRAILER & MATERIALS STORED ON STREET WITH YODOK BARRIERS ENCLOSED WITH FENCING. UPON REQUEST TO GENERAL CONTRACTOR FOR DEPARTM #39530339K | Sep 20, 2024 DEFAULT | $0 |
| Jul 8, 2024 | Construction CLASS - 2 ALTERATION OF A 16 STORY NYCHA RESIDENTIAL BUILDING ACTIVE SITE. OBSERVED SIDEWALK SHED IN PLACE AT EXP#1,2. UPON FURTHER INSPECTION SHED WAS MISSING PROPER SIGNAGE AS PER CODE BC3301.9.2. SHED REQUIRES SIGNAGE #39530338Z | Sep 20, 2024 DEFAULT | $0 |
| Apr 23, 2024 | Construction CLASS - 2 AT TIME OF INSPECTION OBSERVED ACTIVE JOBSITE. UPON REVIEWING SITE SAFETY PLAN ON PAGE 1 AND 3 SHOWS DETAILS AND LOCATIONS OF TREE PROTECTION. NO TREE HAS BEEN PROTECTED AS PER APPROVED SITE SAFETY PLAN. INSTAL #39527870H | Jul 5, 2024 DEFAULT | $0 |
| Apr 23, 2024 | Unknown CLASS - 2 AT TIME OF INSPECTION 7:30AM, OBSERVED ACTIVE JOBSITE. AT ROOF LEVEL OBSERVED 8 OUTRIGGER BEAMS SETUP. UPON REQUESTING NOTIFICATION NUMBER FOR OUTRIGGERS IT WAS NOT PROVIDED. THIS NOTIFICATION IS REQUIRE 24 HOU #39527869K | Jul 5, 2024 DEFAULT | $0 |
| Issued | Violation | Status |
|---|---|---|
| Feb 22, 2023 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9B TECHNICAL REPORT BY 2/21/2023 #01432 | DOB VIOLATION - ACTIVE |
| Feb 19, 2020 | FACADE SAFETY PROGRAM NYCHA UNSAFE CYCLE 8 REPORT FILED #HAZ88795 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Feb 19, 2020 | Facades FISP NYCHA UNSAFE CYCLE 8 REPORT FILED | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 3, 2026, 4:07 AM ET. BBL 2025480042.