4 floors · 8 apartments · 11,045 sq ft · built 1931 · class C4 · owner of record: Pepo Realty Corp
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 63 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 63 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 63 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 79 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-22 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 2, 2026 | Boilers CLASS - 2 FOUND WEIL MCLAIN SERIES #80 OIL FIRED BOILER IN NEED OF SERVICE, SOOT AROUND BOILER, CLEAN OUT DOORS NEED TO BE RESEALED, REQUEST COMBUSTION TEST. #39206517J | Dec 18, 2026 PENDING | $1,250 |
| Dec 4, 2025 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION. AT TIME OF INSPECTION, VIOLATING CONDITIONS WERE REPAIRED; HOLES IN THE CEILING AND AROUND CONDUIT PIPES WERE SEALED WITH FIR #39169304X | Jun 12, 2026 IN VIOLATION | $1,250 |
| Dec 4, 2025 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION. AT TIME OF INSPECTION, VIOLATING CONDITION WAS REPAIRED UNDER PERMIT #X01004370-I1-GC AND SIGNED OFF BY TEOFILO INFANTE. HOWE #39169303Y | Jun 12, 2026 IN VIOLATION | $1,250 |
| Dec 4, 2025 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION. AT TIME OF INSPECTION, VIOLATING CONDITIONS WERE REPAIRED; DOORS ARE LATCHING PROPERLY WITH PUSH BARS. HOWEVER, NO CERTIFICAT #39169305H | Jun 12, 2026 IN VIOLATION | $1,250 |
| Oct 20, 2025 | Construction CLASS - 2 OBSERVED ON THE FIRST FLOOR SPRINKLER HEAD SPRAY OBSTRUCTED BY LIGHT FIXTURE AND NOT USING THE PROPER MATERIAL ON SPRINKLER LINES IN BATHROOMS THROUGHOUT THE BUILDING USING PVC PIPING ON WASTE LINES AND NOT USI #39164109H | Jun 28, 2027 DEFAULT | $6,250 |
| Dec 2, 2024 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE. OBSERVED EXCESSIVE HOLE PENETRATIONS THROUGHOUT BASEMENT LEVEL. IN CASE OF EMERGE #39131698Y | Apr 18, 2025 ADMIT/IN-VIO | $0 |
| Dec 2, 2024 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED DOORS CLOSING BUT NOT LATCHING. IN CASE OF EMERGENCY DOORS MUST CLOSE AND LATCH. THIS CAN LET FIRE OR SMOKE SPREAD THROUGHOUT BUILDING., REPAIR AN #39131697M | Apr 18, 2025 IN VIOLATION | $1,250 |
| Dec 2, 2024 | Construction CLASS - 2 PAINTED SPRINKLER HEADS ON THE SECOND AND FIRST FLOORS. AS PER 102.3 OF THE PLUMBING CODE INSTALLATIONS, BOTH EXISTING AND NEW, AND PARTS THEREOF SHALL BE MAINTAINED IN PROPER OPERATING CONDITION IN ACCORDANCE #39131688K | Apr 18, 2025 ADMIT/IN-VIO | $0 |
| Jul 5, 2024 | Construction CLASS - 2 UNLAWFUL ACTS: FAILURE TO COMPLY WITH COMMISSIONER'S ORDER AS STATED IN ECB# 39098193R ISSUED ON 10/27/2023 AND FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01. FOR FAILURE TO MAINTAIN LI #39118443X | Sep 20, 2024 DEFAULT | $3,125 |
| Dec 29, 2023 | Construction CLASS - 1 UNLAWFUL ACTS: FAILURE TO COMPLY WITH COMMISSIONER'S ORDERS AS STATED IN ECB# 39093599Y ISSUED ON 08/28/2023. PURSUANT TO 28-201.1 AND 1 RCNY 102-01., COMPLY WITH COMMISSIONER'S ORDER; FILE A CERTIFICATE OF COR #39102450H | Apr 26, 2024 IN VIOLATION | $2,500 |
| Oct 27, 2023 | Unknown CLASS - 1 I OBSERVED THE CONNECTION OF FLEXIBLE CORD TO THE JUNCTION BOX SUPPLYING POWER TO THE SIDEWALK SHED ALONG EXPOSURE #3. THIS CORD IS ALSO PASSING THROUGH THE WINDOW AND PLUGGED INTO A WALL OUTLET. THESE USES ARE #39098194Z | Feb 2, 2024 IN VIOLATION | $1,600 |
| Oct 27, 2023 | Construction CLASS - 1 I OBSERVED THE SIDEWALK SHED LOCATED AT EXPOSURES #3 AND 4 WITHOUT ILLUMINATION AS REQUIRED UPON THE COMPLETION OF THE OVERHEAD PROTECTION. AS PER BC 3307.6.4.8 THE UNDERSIDE SHALL BE LIGHTED AT ALL TIMES.; BC #39098193R | Feb 2, 2024 IN VIOLATION | $2,500 |
| Aug 30, 2023 | Construction CLASS - 1 FAILURE TO COMPLY WITH COMMISSION'S ORDER DATED 08/30/23/UNDER COMPLAINT NUMBER 2375239 TO REPAIRS DAMAGED WALLS A REAR OF BUILDING STUCCO MISSING EXPOSING BRICK THAT HAS FALLEN INTO A VACANT LOT ADJACENT TO ST #39131063K | Mar 28, 2025 IN VIOLATION | $1,250 |
| Oct 25, 2021 | Construction CLASS - 2 OCCUPANCY CONTRARY TO THAT ALLOWED BY CERTIFICATE OF OCCUPANCY OR BUILDING DEPT RECORDS.NOTED:OBSERVED AT 1ST FL 1 UNIT USED FOR LOUNGE ROOM DINING ROOM AND LAUNDRY OTHER 1ST FL UNIT USED AS OFFICES CONTRARY TO #35635695M | Feb 18, 2022 IN VIOLATION | $0 |
| Jan 14, 2020 | Construction CLASS - 2 NOTED: OBSERVED ON THE 1ST. FLOOR, UNITS 1 BEING USE AS A LOUNGE,CAFETERIA AND LAUNDRY ROOM AND UNIT 2 BEING USE FOR SECURITY OFFICE AND ADMINISTRATIVE OFFICES, CONTRARY TO CERTIFICATE OF OCCUPANCY #44783., DIS #39015709M | Jan 29, 2021 IN VIOLATION | $0 |
| Jan 17, 2019 | Construction CLASS - 2 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDING DEPARTMENT RECORDS. NOTED: OBSERVED ON FIRST FLOOR, ONE APT IS USED FOR KITCHEN, LAUNDRY, LOUNGE ROOM, ANOTHER APT USE AS OFFICES, #35379801R | Mar 15, 2019 IN VIOLATION | $0 |
| Sep 21, 2017 | Construction CLASS - 2 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O OR DOB RECORDS. C OF O# 44783 INDICATES 1ST STORY TO HAVE 2 APTS W/ 11 SRO'S TOTAL. 5 SRO'S IN 1 APT & 6 SRO'S IN THE OTHER. NOTED: @ TIME OF INSP OBSERVED 1ST S #35293670Z | Nov 17, 2017 STIPULATION/IN-VIO | $0 |
| Jan 5, 2017 | Construction CLASS - 2 OCCUPANCY CONTRARY TO THAT ALLOWED BY C OF O OR BLDG DEPT RECORDS. NOTED: C OF O #44783 INDICATES 1ST FL AS 2 RESIDENTIAL APTS W/SINGLE ROOM OCCUPANCY,OBSERVED 6 OFFICES CONFERENCE ROOM,COMMON DINNING & LIVING #35225700X | Mar 3, 2017 STIPULATION/IN-VIO | $0 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Oct 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle C (premises is in Community District 4) | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Apr 30, 2026 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Aug 3, 2026 |
| Jun 5, 2025 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Sep 8, 2025 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 2, 2026 | ECB | Boilers: FOUND WEIL MCLAIN SERIES #80 OIL FIRED BOILER IN NEED OF SERVICE, SOOT AROUND BOILER, CLEAN OUT DOORS NEED TO BE RESEALED, REQUEST COMBUSTION TEST. | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 28, 2026, 4:06 PM ET. BBL 2027910009.