3 floors · 2 apartments · 3,000 sq ft · built 1931 · class S2 · owner of record: Joseph Randazzo
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 69 days | Keep the report on file (not filed with DOB) |
| Annual property registration Check HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 313 days | Required only if the owner doesn't live there |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 434 days | Next cycle year 2027 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-24 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jun 11, 2008 | Boilers Non-Hazardous B4A,16,32A,38,50A,B,C,D,E,F,G,H,I. 50A. RELIEF VALVE NOT PIPED IN CORRECT POSITION. 50B. BOILER (BASE) REDUCED AT BOILER TAPPING, BOTH NOT INSTALLED TO MANF SPECS. 50C. BOILER HAS DIRECT FEED. 50D. NO CHECK #32056576Y | May 27, 2009 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jan 24, 1989 | ELECTRIC SIGNS #1104W | DOB VIOLATION - ACTIVE |
| Jan 24, 1989 | ELECTRIC SIGNS #ST1104W | DOB VIOLATION - ACTIVE |
None open.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 23, 2026, 8:40 AM ET. BBL 3070990046.