Queens · Block 10155 · Lot 29 · 11433

165-15 Archer Avenue

5 floors · 78,800 sq ft · built 1973 · class O2 · owner of record: Berken Building Co

3open violations
$2,500ECB/OATH penalties owed
0HPD class C (immediately hazardous)
177dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 56 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 78,800 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 177 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 177 days
Annual filing
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 421 days
Next cycle year 2027
Energy audit and retro-commissioning (2035) Likely applies
Local Law 87 · Calendar year 2035
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 10155). Agency page

Dec 31, 2035
in 3343 days
Next due 2035
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-18 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (1) · $2,500 owed
IssuedViolationHearingBalance
Feb 12, 2026Construction CLASS - 1
AT TIME OF INSPECTION OBSERVED SEPARATION AT INTERSECTION OF WALL AND SUPPORT COLUMN OF 5TH FLOOR OFFICE SPACE. ALSO FACADE IN STATE OF DISREPAIR WITH SPALLING/CRACKED MASONRY AT 5TH STY LEVEL OF EXP.3 (REAR OF
#39177155L
Nov 24, 2026
PENDING
$2,500
DOB (1)
IssuedViolationStatus
Feb 12, 2026CONSTRUCTION
ENGINEERS REPORT REQUIRED DUE TO SEPARATION AT INTERSECTION OF WALL AND SUPPORT COLUMN OF 5TH FLOOR OFFICE SPACE.
#26-00504
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Jul 30, 2026AEUHAZ FTC-AEU-HAZ
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Jul 30, 2026DOB SafetyAEUHAZ: Open
Jul 10, 2026ECBConstruction: MISSING PARAPET INFO PANEL CREATING HAZARDOUS CONDITIONS TO THE PUBLIC AND EMERGENCY SERVICES ATTEMPTING TO LOCATE THE BUILDING.PROVIDE AND MAINTAIN PARAPET INFO PANELClosed
Jul 10, 2026ECBConstruction: AT TIME OF INSPECTION OBSERVED VERTICAL MEMBERS OF SIDEWALK SHED AT VEHICULAR ACCESS POINT NOT ADDITIONALLY BRACED OR MARKED WITH HI VISIBILITY MARKINGS TO PREVENT DISLODGMENT IN THE EVENT OF BEING STRUCK BY VEClosed
Jul 10, 2026ECBUnknown: IN RESPONSE TO FDNY'S REQUEST FOR SWS INSPECTION RESEARCH SHOWS SIDEWALK SHED PERMIT UNDER APPLICATION Q01223236 IS EXPIRED CREATING UNSAFE CONDITIONS TO THE PUBLIC AND PROPERTY DUE TO DAILY INSPECTIONS NOT BEIClosed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 5, 2026, 6:20 PM ET. BBL 4101550029.